video corpo

HD200 Silicone J24

HD200 Silicone J24

HD200 Silicone J24

Product catalog summary
Overview: The document is a technical data sheet for the JetFlex® Disc Diffuser - HD 200 Silicone J24, produced by Jaeger Group of Companies. It provides detailed specifications, operational guidelines, and maintenance instructions for the diffuser used in municipal wastewater treatment.
Specifications:
  • Air Flow Rates: Standard operation ranges from 1.5 to 4 m3/h, with a maximum overload rate of 10 m3/h. Operating temperature is between 0 to 100°C.
  • Dimensions: The diffuser has a total diameter of 233 mm and an effective diameter of 184 mm, with a perforated area of 0.025 m2.
  • Materials: The membrane is made of green/transparent silicone with specific mechanical properties such as tensile strength (>9 N/mm2) and elongation at break (>600%).
Installation and Maintenance:
  • Diffusers should be stored in a dark, dry, and ventilated space to avoid damage. Rubber parts should not be stored for more than one year before installation.
  • Maintenance involves using formic acid for cleaning and ensuring maximum airflow for short periods to maintain diffuser condition.
Performance:
  • Standard Oxygen Transfer Efficiency (SOTE): Tested under specific conditions with a water depth of 4.5 m and a temperature of 16.3°C.
  • Headloss: Internal tests show tolerances of +/- 5%.
Disclaimer: The document states that the information provided is based on current knowledge and does not guarantee specific product properties or suitability for particular applications.
See more

Catalog excerpts

HD200 Silicone J24-1

Data Sheet JetFlex® Disc Diffuser - HD 200 Jaeger Group of Companies

 Open the catalog to page 1
HD200 Silicone J24-2

Installation drawing 3/4“–NPT Ø31,8 Grommet (rubber) Ring Support plate Thermoplastic header pipe Dimensions Hight Diameter total/effective Overall height membrane top of tube Perforated area Check valve Air flow Air flow rates at standard operation conditions max overload/ maintenance air flow rate Operating temperature Operation mode intermittent continuous municipal waste water of operation is highly recommended for air flow rates lower than minimum rate. air flow rate (e.g. cleaning) should not be applied longer than 10 min/day. • Numbers are for guidance only. Operating diffusers at too...

 Open the catalog to page 2
HD200 Silicone J24-3

Connectors to header pipe Permitted wall thickness of header tube Diameter of straightdrilled hole Universal Saddle PVC-Saddle 90 mm PVC-Saddle 110 mm Black White/Black White/Black Membrane material Type Colour Silicone green/transparent Density Tensile strength Elongation at break Tear strength Hardness Tension set Ozone resistance zero cracks Support plate material Material Additional colours Shipping unit Dimensions LxWxH Unit weight Shipping unit

 Open the catalog to page 3
HD200 Silicone J24-4

Specifications Standard oxygen transfer efficiency (SOTE) and headloss for HD 200 Silicone J24 12 Water depth Submergence depth Atmospheric pressure Water temperature Test media Test tank tap water bubble column Tank volume Tank floor area CSS,T Test conditions SOTE acc. to German Standard DWA M 209 (desorption method) Certificate ISAH, University Hanover, measuring tolerance +/- 1% Headloss internal tests tolerances +/- 5% Storage: • Diffuser and/or rubber sleeves must be stored factory-packed in a dark, dry, ventilated and dust-free storage space according to DIN 7716. Avoid frost, heat, UV/radiation,...