PAR - MAX SERIES WASHDOWN/BAITWELL — 31700-SERIES BILGE/LIVEWELL/GENERAL PURPOSE — 31705-SERIES Models 31700, 31705-Series Self-Priming to 10 ft. (3 m) Run Dry Without Damage Smooth Flow Four Piston, Diaphragm Pump Powerful Heavy Duty Motor with Thermal Overload Protection • Snap-in Ports • Waterproof Coating • Pressure Switch with Rubber Boot (31700-Series) • Meets USCG Regulation 183.410 and EN ISO 8846 MARINE (Ignition Protection Standards) • Meets EN 50081-1 Electro-magnetic Compatibility 31705-Series Complies with EN ISO 8849 MARINE Electric Bilge Pump GENERAL APPLICATIONS 31700-Series – High velocity pump for anchor and general deck washdown. Compact size with matched hioutput spray nozzle. Corrosion resistant coated motor and sealed pressure switch for fresh or salt water use. Also great for continuous duty operation in livewell application at full flow. 31705-Series – For bilge/livewell/G.P. applications that do not require a pressure switch. Low amp draw, can run dry. Oil resistant parts allow pumping of diesel fuel. SPECIFICATIONS • Pump Body – Glass Filled Polypropylene • Pump Design – Multi-Chamber Diaphragm • Suction Lift – Self Priming to 10 ft. (3 m) • Ports – 3/4" (19 mm) Hose Barb or 1/2" (13 mm) • Motor – Permanent Magnet • Shipping Weight – Weight - 6.5 lb (3.0 kg) WARNING! Explosion hazard. Do not pump gasoline, solvents, thinners or other flammable liquids. To do so can cause an explosion resulting in injury or death. VARIATIONS MODELS WASHDOWN/BAITWELL WASHDOWN/BAITWELL WASHDOWN/BAITWELL WASHDOWN/BAITWELL BILGE/LIVEWELL/G.P. BILGE/LIVEWELL/G.P. * Customer supplied, not included with pump. DIMENSIONAL DRAWINGS — INCHES (mm)
Open the catalog to page 1Bilge Pump Pumpguard TM Inlet Strainer TM Fig. 2 31700-Series w/Rule® Dual Port MOUNTING The Jabsco pumps are self-priming and may be located above or below the fresh water supply in a dry location. To vertically mount these units, it is best to do so with the motor on top. This will prevent water dripping on motor in the event of a leak. Place pump on a solid surface and secure with the four mounting screws being careful not to compress the rubber grommets which act as shock absorbers. Quick Easy Installation Versatile Snap-in Ports The electrical circuit should be protected with an overcurrent...
Open the catalog to page 2WARNING: DISCONNECT POWER TO PUMP AND OPEN VALVE TO RELIEVE WATER PRESSURE PRIOR TO SERVICING PUMP EXPLODED VIEW DESCRIPTION Upper Housing Valve Kit Diaphragm Kit Lower Housing Kit Pressure Switch Service Kit Motor Kit – 12V EMC COMP 24V EMC COMP Slide Clips Pumphead Assy. PumpgardTM Strainer Spray Nozzle US Spray Nozzle EC Pressure Switch (5) 1. Disconnect power to pump and open a faucet or valve to relieve system pressure. 2. Remove Rubber Boot, then remove the two visible Pressure Switch Screws located on each side of the Pressure Switch (5). Upper Housing (1) 3. Slide Port Clip (8) back and...
Open the catalog to page 3Possible Cause(s) Pump will not prime or retain prime after operating Pump runs but no fluid Pump leaks 1. Air leak in suction line 3. Upper housing leaking (Key 1) 4. Suction lift too high 1. Faulty suction piping 3. Suction lift too high 5. Inlet line valve closed 2. Insufficient ventilation for motor 1. Piping or hose is damaged 5. Tank over pressurized 1. Upper housing loose (Key 1) 3. Pump head loose on motor 2. Defective pressure switch (Key 5) 3. Motor has open circuit (Key 7) 2. Insure proper ventilation 5. Check tank pressure 3. Tighten pump head 1. Check connections, fuse, breakers...
Open the catalog to page 412 Pages
8 Pages
4 Pages
4 Pages
2 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
14 Pages
14 Pages
52 Pages
2 Pages
4 Pages
8 Pages
16 Pages
12 Pages
8 Pages
6 Pages
16 Pages
18 Pages
38 Pages
40 Pages
4 Pages
3 Pages
12 Pages
26 Pages
15 Pages
29 Pages
37 Pages
10 Pages
2 Pages