UPS - System Battery-buffered power supply
2Pages

{{requestButtons}}

Catalog excerpts

UPS - System Battery-buffered power supply - 1

Battery-buffered power supply manufacturer: J. Schneider Elektrotechnik GmbH type : AKKUTEC 2403 art.-no. : NBUA 2403 DC-0523G01 Short description The battery buffered DC power supply of the series AKKUTEC is working according the stand-by parallel mode and ensures in connection with a lead-acid accumulator a safe continuous DC power supply in case of mains failure. The back-up time is depending from the state of charge of the accumulator and of the discharge current. The power supply has the following features: • Battery charger with I/U-charging characteristics • Battery management by micro-controller • Battery voltage tracking of the charging voltage by external sensor module (optional) Nominal input voltage Nominal frequency Nominal output voltage Depending of state of charge of the battery Nominal output current Protective system Secure separation (safe separation between input and output) Operational temperature Short circuit protection Battery Type of battery Battery fuse Back-up time Charging characteristics Charging current at 100% load Charging current at 0% load Deep discharge protection of the battery 24 V AC 47 – 63, Hz 26,8 V DC ± 0,4% 19,8 – 26,8 V DC ± 0,4% 2,85 A at 100% ED current limiting at 1,1 x I Nenn IP 20 According to EN61558-2-17 (VDE 0570 2-17) 0 - 40 ° C optimal storage temperature for battery 20° Durin g C. storage charge battery each 6 month. electronic, short-circuit-proof output External Pb-Akku, maintenance free Pb- Akku maintenance free (Option with modified characteristic curve) External Depending on battery and load I/U DIN 41773 Teil 1 Opt. Battery voltage tracking 0.25 A 2,85 A Load rejection at a battery voltage ≤ 19,8 V

Open the catalog to page 1
UPS - System Battery-buffered power supply - 2

Relais-outputs Control input referring to earth 24 V Shut down terminal (emergency stop) Battery management Battery circuit control Real battery power control Type of construction Connection Dimensions Net OK green input voltage is present Battery OK green expires at: -battery circuit interruption (battery fuse damaged) -voltage in UPS operation < 21,6 V (Battery low.) -battery temperature above 45° C LED is blinking at -battery low (damaged battery) Mains/UPS-operation 0,5 A /30 V DC general error 0,5 A /30 V DC As shut down Software for PC Abort of the UPS- operation Potential free switch...

Open the catalog to page 2

All J. Schneider Elektrotechnik catalogs and technical brochures

  1. CEM 24-8

    2 Pages

  2. CEM 24-2

    2 Pages

  3. UCC-TEC

    2 Pages

  4. UCC-TEC 450

    2 Pages

  5. CEM 24-1

    2 Pages

  6. AKKUTEC 2405

    2 Pages

  7. UPSO 2420

    2 Pages

  8. DC-UPS

    3 Pages

  9. MLM 10 - 20

    11 Pages

  10. AKKUTEC SVC

    2 Pages

  11. MLT C 10 - 20

    10 Pages

  12. C-TEC 1203-1

    1 Pages

  13. UNOTEC 2420

    2 Pages

  14. UNOTEC 2405N

    2 Pages

  15. CEM12V12

    1 Pages

  16. CEM1

    1 Pages

  17. AKKUTEC 2403

    2 Pages

  18. AKKUTEC 2405

    2 Pages

Archived catalogs

  1. DC-UPS systems

    16 Pages

  2. Focus on

    16 Pages