MLT C 10 - 20
10Pages

{{requestButtons}}

Catalog excerpts

MLT C 10 - 20 - 1

J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line UPS-system MLT C 10 - 20 On-Line UPS-system in double conversion technology according to IEC / EN 62040-3 (VFI-SS111) with sinus soidal output voltage in each operation mode, LCD display, RS232 interface, USB connection, alarm contacts, emergency stop function, 2 slots for communication cards, shutdown-software for Windows NT/2000/XP/2003/ Vista, Novell und Linux system software. Optionally up to 6 systems may be switched in parallel. The operation modes on-line, line-interactive, smart active or emergency supply (Standby) can be adjusted with the means of the display. Energy storage: Double-layer capacitors. Suitable for short-term buffering. Maintenance free and very temperature-independent nominal rating in kVA nominalt rating in kW back-up time in minutes with capacitors set 100-9P 100 % load 50% load input number of phases nominal voltage tolerance of input voltage by 100% load tolerance of input voltage by 50% load nominal frequency tolerance of frequency nominal input current [3-phase] maximum inrush current [3-phase] inrush current power factor (cos ϕ) harmonical distortion (THDI) MLT_C_10_20_e Adresse: Helmholtzstrasse 13 D-77652 Offenburg Stand: 06/2009 Technische Änderungen vorbehalten Geschäftsführer: Bettina Schneider, Dipl. Betriebswirt (BA) Rolf Anti, Dipl.-Wirt.-Ing. (FH) Amtsgericht Offenburg HRB 758

Open the catalog to page 1
MLT C 10 - 20 - 2

J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line UPS-system MLT C 10 - 20 model „Hold-Up time“ back-up time without switching on doublelayer capacitor – no interruption of the output voltage occurs 3+N 380 / 400 / 415 V Sinus ± 1% ± 3% < 10ms ≤ 1% ≤ 3% 50 or 60 Hz ±2 % (adjustable from ± 1% to ± 5%) 2 Hz / second 50 or 60 Hz ± 0,01% 3:1 1,5 x In for 0,5 sec effectiveness in Line-Interaktiv operation load 100% 115 %: endless 125 % for 10 minutes 150 % for 1 minute 168 % for 5 seconds > 168 % for 0,5 seconds 110 % for...

Open the catalog to page 2
MLT C 10 - 20 - 3

J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line UPS-system MLT C 10 - 20 model Bypass (static) nominal rating in kVA nominal voltage number of phases accepted voltage range Range of input frequency bypass overload Bypass (manuell) Manual button to carry out maintenance work at the UPS without interrupting the power supply to the load. Double-layer capacitor nominal voltage number of U-cells nominal capacity per cell configuration type type of recharge charge current by rated load charging time LCD display big graphic...

Open the catalog to page 3
MLT C 10 - 20 - 4

J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line UPS-system MLT C 10 - 20 model interfaces Sub-D 9 Pin female connector USB-female connector Sub-D 15 Pin female connector 2 Slots Emergency Stop RS232 interfaces Serial interfaces potential-free alarm interface for: - mains failure (changer) - low battery (changer) - system on bypass (changer) - auxiliary supply (12V/100mA) for long distance signal - input for long distance signal (Stop inverter) - input for long distance signal (Stop UPS) 2 slots for communication...

Open the catalog to page 4
MLT C 10 - 20 - 5

J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line UPS-system MLT C 10 - 20 model environmental conditions operation temperature maximum relative humidity maximum installation heigth cooling noise in 1m distance (depending on load and temperature) 95 % (without condensation) till 1000 m at nominal load (-1% für each 100 meters above 1000 m) - max. 4000 m forced air circulation (load-dependent arranged) ≤ 48 ≤ 52 cabinet material Sheet steal colour RAL 7016 (Anthrazitgrey) protection class IP 20 the rear side of the...

Open the catalog to page 5
MLT C 10 - 20 - 6

J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line UPS-system MLT C 10 - 20 model Optionen external service by-pass manual by-pass switches the load from the inverter to the mains power supply without interrupting the output power supply in case of maintenance. dimension (H x B x T) in mm Weight Parallel connection Up to 6 UPS-systems with the same rating can be switched in parallel to increase the safety or to increase the rating. SNMP Interfacebox for direkt connection to a network Software network version of...

Open the catalog to page 6
MLT C 10 - 20 - 7

J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line UPS-system MLT C 10 - 20 model options Remote display Multi Panel: Remote display with a graphical screen Multi I/O 8 programmable relay outputs 8 digital/analogue inputs (0 to 5V DC) 1 RS232 interface to the UPS system 1 RS232 interface for control 1 RS232/RS485 interface for control AS/400 Cable set for the connection at AS/400 systems MLT_C_10_20_e Adresse: Helmholtzstrasse 13 D-77652 Offenburg Stand: 06/2009 Technische Änderungen vorbehalten Geschäftsführer: Bettina...

Open the catalog to page 7
MLT C 10 - 20 - 8

J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line UPS-system MLT C 10 - 20 indication- and control panel LED standby / alarm MLT_C_10_20_e Adresse: Helmholtzstrasse 13 D-77652 Offenburg Stand: 06/2009 Technische Änderungen vorbehalten Geschäftsführer: Bettina Schneider, Dipl. Betriebswirt (BA) Rolf Anti, Dipl.-Wirt.-Ing. (FH) Amtsgericht Offenburg HRB 758

Open the catalog to page 8
MLT C 10 - 20 - 9

J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line UPS-system MLT C 10 - 20 front elevation Panel with graphic display From left: Separation switch, Battery safety fuse, manual bypass switch, button for start with battery ( COLD START) /Mainswitch 1/0 Front door ( press it to open the door and loosen the part which is signed with a X ) From left:: Input switch / separated Bypass- switch (option) / output switch Ventilation grill Protective cover ventilation grill Brake food MLT_C_10_20_e Adresse: Helmholtzstrasse 13...

Open the catalog to page 9

All J. Schneider Elektrotechnik catalogs and technical brochures

  1. CEM 24-8

    2 Pages

  2. CEM 24-2

    2 Pages

  3. UCC-TEC

    2 Pages

  4. UCC-TEC 450

    2 Pages

  5. CEM 24-1

    2 Pages

  6. AKKUTEC 2405

    2 Pages

  7. UPSO 2420

    2 Pages

  8. DC-UPS

    3 Pages

  9. MLM 10 - 20

    11 Pages

  10. AKKUTEC SVC

    2 Pages

  11. C-TEC 1203-1

    1 Pages

  12. UNOTEC 2420

    2 Pages

  13. UNOTEC 2405N

    2 Pages

  14. CEM12V12

    1 Pages

  15. CEM1

    1 Pages

  16. AKKUTEC 2403

    2 Pages

  17. AKKUTEC 2405

    2 Pages

Archived catalogs

  1. DC-UPS systems

    16 Pages

  2. Focus on

    16 Pages