DC-UPS systems
16Pages

{{requestButtons}}

Catalog excerpts

DC-UPS systems - 1

J. Schneider Elektrotechnik GmbH DC-USV Anlagen 2 A - 600 AUltracup-Module 0,2 A - 600 A DC-UPS systems 2 A - 600 A Ultracup-modules 0.2 A - 600 A >

Open the catalog to page 1
DC-UPS systems - 2

Schneider offers a wide range of products of DC-UPS-systemsfrom 2 A to 900 A and bigger, the software, and comprehensive service achievements.Remarkable features of Schneider DC-UPS-systems are beside the well-known Schneider quality the following ones: ߷ the systems work mainly in parallel operation (online) for every system until 40 A low discharge protection through load rejection as standard׷ battery control by real measurement of battery voltage permanent battery test ׷ shut-down function adjustable bridging time׷ short delivery times (most of the systems on stock) ׷ in case of special...

Open the catalog to page 2
DC-UPS systems - 3

The following operation modes are used depending on system and application: In case of parallel operation consumer, DC-source and battery work permanent in parallel. In case of standby-parallel mode (Online-mode) the DC-source must be able to supply permanently the battery and the consu-mer. The battery is kept full charged and only spends energy when the DC-source or the mains fails.In case of Die folgenden Betriebsarten werden je nach Gert und Anwendung eingesetzt: Bei Parallel-Betrieb sind Verbraucher, Gleich-stromquelle und Batterie stndig parallel ge-schaltet. Beim...

Open the catalog to page 3
DC-UPS systems - 6

Eingang Ausgang Bemessungs-SpannungsbereichNetzfrequenz primre Absicherung Bemessungs-Spannungbei BatteriebetriebLadeschluspannung max. Laststrom max. Ladestrom Ableitstrom Batterie 䟜berbrckungszeit*** allgemeine Daten KennliniePFC, Netz-Oberwellen am Eingang gem. EN61000-3-2Bemessungs-Temperaturbereich bei Batterie Tiefentladeschutz / Lastabwurf bei 19,8V > Normen sichere Trennung לbertragerSchutzklasse Schutzart EMV gem EN 55011, EN 50082-2 mechanische Daten > Eingang Bemessungs-SpannungsbereichNetzfrequenzprimפre Absicherung > Ausgang Bemessungs-Spannungbei Batteriebetrieb...

Open the catalog to page 6
DC-UPS systems - 7

Bemessungs-SpannungsbereichNetzfrequenz primre Absicherung Bemessungs-Spannungbei BatteriebetriebLadeschluspannung max. Laststrom max. Ladestrom Ableitstrom Batterie 䟜berbrckungszeit** allgemeine Daten KennliniePFC, Netz-Oberwellen am Eingang gem. EN61000-3-2Bemessungs-Temperaturbereich bei Batterie Tiefentladeschutz / Lastabwurf bei 19,8V > Normen sichere Trennung לbertragerSchutzklasse Schutzart EMV gem EN 55011, EN 50082-2 mechanische Daten Gewicht, ca. 3 x 2,0 At20 A22 A 2,6 kg 3 x 4 A, tr䟤ge40 A42 A 3,0 kg > Eingang Bemessungs-SpannungsbereichNetzfrequenzprimre Absicherung Ausgang...

Open the catalog to page 7
DC-UPS systems - 8

TEC TEC TEC 2402 + NBBH 2401AKKU 2402 + NBBH 2401AKKU 2402 + NBBH 2401AKKU TEC TEC TEC > 2402 + NBBH 2401Akku 2402 + NBBH 2401AKKU 2402 + NBBH 2401AKKU TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC 0,5 A1A2 A5 A10 A15 A20 A 40 A80 A AKKU 2402 + NBBH 2401AKKU 2402 + NBBH 2401AKKU 2402 + NBBH 2401AKKU 2402 + NBBH 2401AKKU 2402 + NBBH 2401AKKU 2402 + NBBH 2401AKKU 2402 + NBBH 2402AKKU 2402 + NBBH 2402AKKU 2402 + NBBH 2407AKKU 2402 + NBBH 2412AKKU TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC 2405 +NBBH 2401AKKU 2405 +NBBH 2402AKKU 2405 +NBBH 2402AKKU 2402 + NBBH 2401AKKU 2402 + NBBH 2401AKKU 2402 + NBBH...

Open the catalog to page 8
DC-UPS systems - 9

Abmessungendimensions AKKU TEC 2420 AKKU TEC 2420-12 AKKU TEC 2410-12 TEC 2410AKKU TEC 2405 USB AKKU TEC 2402AKKU TEC 19-2403AKKU > 11TE 55,0 AKKUTEC TEC 19-2420 AKKU > NetzError Unterhalb Oberhalb 3HE 128,4 TEC 2440 AKKU >

Open the catalog to page 9
DC-UPS systems - 10

Anzeigen- und Bedienpanelfr Programmierung und Visualisierung Display, control and indicator panelfor programming and visual impressions > Das Display-, Bedien- und Anzeigenpanel weist folgende Eigenschaften auf: Gut ablesbares, 20-stelliges, 2-zeiliges alphanummerisches LC-Display mit Hintergrundbeleuchtung췷 Getrennte Einstellmglichkeit fr Kontrast und Helligkeit 漷 Versorgung sowie Datentransfer ber 2-Draht Bus, dadurch u줟erst geringer Verdrahtungs- aufwand Auslesen und Beschreiben der Lade- und לberwachungsparameter Klartextdarstellung von Statusmeldungen׷ Signalton bei Warnungen bzw....

Open the catalog to page 10
DC-UPS systems - 11

Temperatursensor MTIAzur Batteriespannungsnachfhrungfr eine optimale Ladespannung Temperature sensor MTIAfor battery voltage tracking Die Lebensdauer von Batterien ist bei einer Tem-peratur von 20켰C angegeben. Temperaturen ber 20C an den Batterien f찼hren zu einer drasti-schen Verkrzung der Lebensdauer der Batterien.Durch den Temperatursensor, der am AKKU The life span of batteries is indicated at a tem-perature of 20C. Temperatures over 20찰C at the batteries lead to a drastic reduction of the life span of the batteries.Through the temperature-sensor, attached on the AKKU TEC an den IO-1...

Open the catalog to page 11
DC-UPS systems - 12

׷ mounting position optional (not standing on the head) mechanically strong ABS-container׷ certified by VdS and Underwriters Laboratories Valve-regulated design with nearly 100% gas recombination during float charging׷ AGM=Absorbing GlassMatt technology in which the electrolyte is absorbed or in gel no topping up of electrolyte necessary׷ High current drain grid being resistant to corrosion by virtue of a lead-calcium alloy wide range of operating temperatures with temperature compensated charging׷ very good charging efficiency classified as "non-spillable" and therefore exempt from IATA...

Open the catalog to page 12
DC-UPS systems - 14

Beispiele kundenspezifischer AnlagenExamples of customer specified UPS systems >

Open the catalog to page 14
DC-UPS systems - 15

U U U U Netzbetrieb Netzbetrieb Fehler Fehler Batt >

Open the catalog to page 15

All J. Schneider Elektrotechnik catalogs and technical brochures

  1. CEM 24-8

    2 Pages

  2. CEM 24-2

    2 Pages

  3. UCC-TEC

    2 Pages

  4. UCC-TEC 450

    2 Pages

  5. CEM 24-1

    2 Pages

  6. AKKUTEC 2405

    2 Pages

  7. UPSO 2420

    2 Pages

  8. DC-UPS

    3 Pages

  9. MLM 10 - 20

    11 Pages

  10. AKKUTEC SVC

    2 Pages

  11. MLT C 10 - 20

    10 Pages

  12. C-TEC 1203-1

    1 Pages

  13. UNOTEC 2420

    2 Pages

  14. UNOTEC 2405N

    2 Pages

  15. CEM12V12

    1 Pages

  16. CEM1

    1 Pages

  17. AKKUTEC 2403

    2 Pages

  18. AKKUTEC 2405

    2 Pages

Archived catalogs

  1. Focus on