AKKUTEC 2410-0
2Pages

{{requestButtons}}

Catalog excerpts

AKKUTEC 2410-0 - 1

Battery- buffered power supply in Parallel operation (On-Line) without battery for ext. battery manufacturer: J. Schneider type : AKKUTEC 2410-0 Art.-No. : NBPAN33G1M01 1. Short description The battery buffered DC power supply of the series AKKUTEC is working according the stand-by parallel mode and ensures in connection with a lead-acid accumulator a safe continuous DC power supply in case of mains failure. The power supply has the following features: • • • • • Primary switched power supply with I/U-charging characteristics active power factor correction (PFC) Battery management by micro-controller Battery voltage tracking of the charging voltage by external sensor module (optional) Display- and control panel for mount in cabinet door or module (optional) Nominal input voltage Nominal frequency Nominal output voltage Depending of state of charge of the battery Nominal output current Protective system Secure separation (safe separation between input and output ) Operational temperature Short circuit protection battery Battery fuse Back-up time Charging characteristics Final charging voltage Charging current at 100% load Charging current at 0% load Deep discharge protection of the battery LED-display Control inputs referring to earth on +24VDC 230 V AC -15% +10% 50/60 Hz 24 V DC ± 0,5% 19,8...26,4 V DC 10 A bei 100% ED IP 20 According to EN61558-2-17 0 - 40 ° C optimal storage temperature for battery 20° Durin g C. storage charge battery each 6 month. electronic, short-circuit-proof output external external Depending on battery I/U DIN 41773 part 1 Opt. Battery voltage tracking Boost-charge via controla contact ( til 28,6V ) 26,4 V DC 1,5 A 11,5 A load rejection at a battery voltage ≤ 19,8 V mains / battery operation 'Netz OK' green LED illuminates general error 'Fehler' yellow LED illuminates battery voltage within green LED illuminates battery voltage above green LED illuminates mains/UPS-operation 0,5 A /30 V DC general error 0,5 A /30 V DC battery voltage above 0,5 A /30 V DC battery voltage within 0,5 A /30 V DC Shut-down

Open the catalog to page 1
AKKUTEC 2410-0 - 2

Special features expendable active PFC Battery management Battery circuit control Real battery power control Type of construction connection dimensions boost charge Active current division at Master – Slave respectively redundant operation via CS-Bus Time function (load rejection after adjustable back-up time) In 10A steps Master/Slave Harmonic ripple at input according to EN 61000-3-2 PF ∼ 0,99 Battery management via internal Microcontroller, control battery circuit / battery fuse each 60sec Battery load test during mains operation (load of the battery with simultaneous voltage measurement...

Open the catalog to page 2

All J. Schneider Elektrotechnik catalogs and technical brochures

  1. CEM 24-8

    2 Pages

  2. CEM 24-2

    2 Pages

  3. UCC-TEC

    2 Pages

  4. UCC-TEC 450

    2 Pages

  5. CEM 24-1

    2 Pages

  6. AKKUTEC 2405

    2 Pages

  7. UPSO 2420

    2 Pages

  8. DC-UPS

    3 Pages

  9. MLM 10 - 20

    11 Pages

  10. AKKUTEC SVC

    2 Pages

  11. MLT C 10 - 20

    10 Pages

  12. C-TEC 1203-1

    1 Pages

  13. UNOTEC 2420

    2 Pages

  14. UNOTEC 2405N

    2 Pages

  15. CEM12V12

    1 Pages

  16. CEM1

    1 Pages

  17. AKKUTEC 2403

    2 Pages

  18. AKKUTEC 2405

    2 Pages

Archived catalogs

  1. DC-UPS systems

    16 Pages

  2. Focus on

    16 Pages