FLEXIBLE ROGOWSKI COIL CURRENT TRANSDUCER - 12 Pages

Add to MyDirectIndustry favorites
FLEXIBLE ROGOWSKI COIL CURRENT TRANSDUCER

Catalog excerpts

PRECISION CLAMP ON FLEXIBLE ROGOWSKI COIL CURRENT TRANSDUCER SINGLE PHASE output : 4-20mA DC THREE PHASE J&D Rogowski coil current transducer is suitable for primary ranges from 250 to 6,000A AC with 4-20mA and 0-5V DC secondary. It improves both conductor positioning error and influence by external magnetic field. As split clip flexible outfit, it can be easily installed even at limited space without cutting power line. Main applications are Protection systems monitoring, Condition monitoring, Process / Control monitoring for PLCs and SCADA software, and etc. Inner Diameter(mm) Current Range Secondary Output • Insulation CATⅢ 1000V, CATⅣ 600V AC • Certificated for UL & CE complying with IEC61010-1 CLAMP ON FLEXIBLE ROGOWSKI COIL CU

 Open the catalog to page 1

CONTENTS PRECISION CLAMP ON FLEXIBLE ROGOWSKI COIL CURRENT TRANSDUCER 3    JRFS-XXXS/A(X-XXX)    Series 9    JRFS-XXX-M/P (X-XXX) Series 11    JRFS-XXX-R/U (X-XXX) Series CLAMP ON FLEXIBLE ROGOWSKI COIL CURRENT TRNSDUCER 2

 Open the catalog to page 2

Precision Clamp on    _Flexible Rogowski coil CT JRFS-XXXS/A(X-XXX) Series a/v PROBE HEAD ONLY Clamp-on Flexible Rogowski coil Current Transformer has been designed for accurate measurement of wide AC current, pulsed DC or distorted waveforms. It may be used to measure AC current over a wide dynamic range and from 10Hz to 20kHz. APPLICATIONS • Very high current monitoring • DC ripple measurement • Harmonics and transients monitoring • Power monitoring & control systems • Applicable in eletronic Watt-hour meter FEATURES • AC current probe utility by the Rogowski principle • Flexible and...

 Open the catalog to page 3

OPTION : INTEGRATOR S/T-XXX SERIES Output : 4-20mADC / 0-5VDC 86.00 SINGLE PHASE INPUT OUTPUT POWER THREE PHASE INPUT OUTPUT POWER CLAMP ON FLEXIBLE ROGOWSKI COIL CURR

 Open the catalog to page 4

Precision Clamp on Flexible Rogowski coil CT ^ i JRFS-XXX(X-XXX) Series PROBE HEAD ONLY CX J&D's new Micro-accuracy flexible rogowski coil measures even sensitive error to use special magnetic winding technology with small size. It is very effective for small sized AC measuring utility since it reduces chronically affected errors on existed Rogowski coil by conductor's position. APPLICATIONS • Energy sub-meters • Power meters • Power quality monitoring • Condition monitoring • Distributed measurement systems FEATURES • 080, 0115mm sensing aperture for non-contact measurement • Very low...

 Open the catalog to page 5

OPTION : INTEGRATOR S/T-XXX SERIES Output : 4-20mADC / 0-5VDC 86.00 SINGLE PHASE INPUT OUTPUT POWER THREE PHASE INPUT OUTPUT POWER CLAMP ON FLEXIBLE ROGOWSKI COIL CURR

 Open the catalog to page 6

Precision Clamp on Flexible Rogowski coil CT JRFS-XXXY(X-XXX) Series a/v PROBE HEAD ONLY J&D's new Micro-accuracy flexible rogowski coil measures even sensitive error to use special magnetic winding technology with small size. It is very effective for small sized AC measuring utility since it reduces chronically affected errors on existed Rogowski coil by conductor's position. APPLICATIONS • Very high current monitoring • DC ripple measurement • Harmonics and transients monitoring • Power monitoring & control systems • Applicable in eletronic Watt-hour meter FEATURES • 035 / 055 / 080 /...

 Open the catalog to page 7

OPTION : INTEGRATOR S/T-XXX SERIES Output : 4-20mADC / 0-5VDC single phase CLAMP ON FLEXIBLE ROGOWSKI COIL CURRENT TRNSDUCER 8

 Open the catalog to page 8

Precision Clamp on    _Flexible Rogowski coil CT JRFS-XXX-M/P (X-XXX) Series IP 67 Clamp-on Flexible Rogowski coil Current Transducer has been designed for accurate measurement of AC current with a safe output voltage RMS. JRFS-XXX-M/P/R/U (X-XXX) series is the precision current probe for Revenue-Grade Distribution transformer monitoring. With voltage integrator configuration, it can replace the existing CT directly. APPLICATIONS • Revenue-Grade distribution transformer monitoring • Energy sub-meters • Power meters • Power quality monitoring • Condition monitoring • Distributed measurement...

 Open the catalog to page 9

OPTION : INTEGRATOR S/T-XXX SERIES Output : 4-20mADC / 0-5VDC 86.00 SINGLE PHASE INPUT OUTPUT POWER THREE PHASE INPUT OUTPUT POWER CLAMP ON FLEXIBLE ROGOWSKI COIL CURRE

 Open the catalog to page 10

Precision Clamp on Flexible Rogowski coil CT JRFS-XXX-R/U (X-XXX) Series PROBE HEAD ONLY S1 ● ● POWER SUPPLY 5, 12, 24V DC S2 ● Vin+ Vin - ● Clamp-on Flexible Rogowski coil Current Transducer has been designed for accurate measurement of AC current with a safe output voltage RMS. JRFS-XXX-R/U (X-XXX) series is the precision current probe for Revenue-Grade Distribution transformer monitoring. With voltage integrator configuration, it can replace the existing CT directly. • Revenue-Grade distribution transformer monitoring • Energy sub-meters • Power meters • Power quality monitoring •...

 Open the catalog to page 11

OPTION : INTEGRATOR S/T-XXX SERIES Output : 4-20mADC / 0-5VDC 86.00 SINGLE PHASE INPUT OUTPUT POWER THREE PHASE INPUT OUTPUT POWER CLAMP ON FLEXIBLE ROGOWSKI COIL CURR