Overview: The document provides technical specifications and operational details for the EWN-A series electromagnetic metering pumps, designed for handling gaseous liquids such as sodium hypochlorite and hydrogen peroxide without gas locking.
Specifications: The pumps feature an automatic air vent mechanism that ensures reliable air venting and prevents gas lock. They are capable of pumping concentrated sodium hypochlorite and resume operation immediately after a stoppage. The pumps operate at a power voltage of 100-240 VAC with a frequency of 50/60Hz and have adjustable stroke lengths and rates.
Components: Key components include the suction port, valve, automatic air vent valve, pump head, fitting adapter, and manual air vent port. The wet-end materials are primarily PVC, PTFE, and EPDM, with some parts made from alumina ceramic and Hastelloy C276.
Operation Principle: Air from the suction port is directed through the pump head to the connection adapter. Due to pressurization on the pump discharge side, air is expelled through the automatic air vent valve. The pump returns to normal operation once air is expelled, with a small amount of liquid discharged from the automatic bleed valve.
Models and Variants: The document lists various models such as ETU-25N-B11N and ETU-50NR-B21N, each with specific configurations and optional accessories like tank drain valve sets and level gauges.
Safety and Legal Considerations: Users are advised to read the instruction manual carefully for safe use. The document also notes that export licenses may be required due to international export control regulations.
Contact Information: The document provides contact details for IWAKI offices across Europe, the USA, and Asia/Oceania for further inquiries and support.
See more

Catalog excerpts

EWN-A series-1

EWN-A N E W series P R O D U C T Electromagnetic metering pumps Automatic air vent type The optimum for gaseous liquid feeding Electromagnetic metering pumps This type equips automatic air vent mechanism. An air vent valve builtin pump chamber enables reliable air venting. Also equipped manual air vent valve enables easy pressure release in discharge piping. Gaseous liquid such as sodium hypochlorite or hydrogen peroxide can be injected without gas locking. • Entrained air is automatically expelled from the pump head. No special degassing is needed. • The pump immediately resumes operation without gas lock even after a long period of stoppage. • Use the air vent port manually for quick release of discharge line pressure. • Capable of pumping concentrated sodium hypochlorite Principle of operation Manual air vent port Manual air vent adjusting screw Air • Air which comes from suction port goes to the connection adapter through pump head. Because Automatic air vent valve pump discharge side is pressurized, air goes to the automatic air vent valve which the pressure load is Valve lower than pump discharge side, and goes out little by little together with liquid. Pump head • Once the pump gets out of locked air condition, it returns to normal operation to discharge the liquid. A ittle bit of liquid is discharged from automatic bleed valve, too. Fitting adapter Suction port

 Open the catalog to page 1
EWN-A series-2

Pump identification EWN - B 11 VC Series symbol EWN-A series E R A- Drive unit symbol Average power consumption B: 20W C: 24W Diaphragm diameter Effective diaphragm dia. 11: 10mm 16: 15mm 21: 20mm Special configuration code Special version code A : Automatic air vent type Controller function code R: Standard type Wet-end material symbol For details, see the table of materials. VC,VH Power code E: with European cord Connection For details, please contact us. Wet-end materials 12 6 Parts name 1 Pump head 2 Fitting nut 3 Air vent body B 4 Lock nut 5 Diaphragm 6 Air vent body A 7 Valve guide 8 Valve...

 Open the catalog to page 2

All IWAKI catalogs and technical brochures

  1. CL-60WL

    2  Pages

  2. F series

    12  Pages

  3. FS series

    8  Pages

  4. KB series

    2  Pages

  5. V series

    8  Pages

  6. HRP series

    2  Pages

  7. EH-E series

    4  Pages

  8. EW-Y series

    4  Pages

  9. EW series

    8  Pages

  10. EWN-R series

    8  Pages

  11. IX series

    12  Pages

  12. LK series

    8  Pages

  13. RD series

    4  Pages

  14. MD-F series

    10  Pages

  15. MD series

    12  Pages

  16. EWN-Y series

    2  Pages

  17. PDS series

    8  Pages

  18. APN series

    8  Pages

  19. GM-V series

    8  Pages

  20. MDG series

    8  Pages

  21. MDT series

    2  Pages

  22. NFA-T series

    8  Pages

  23. TC-300

    2  Pages

  24. IS series

    6  Pages

  25. HM series

    4  Pages

  26. MX-F series

    8  Pages

  27. MX series

    8  Pages

  28. AMP series

    2  Pages

  29. MDM series

    8  Pages

  30. MDW series

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.