Catalog excerpts

MD-F, MD-V-1

IWAKI MAGNETIC DRIVE PUMPS MD-F MD-V Main material MD-F: CFRETFE MD-V: CFRPVDF Solutions for chemical handling applications

 Open the catalog to page 1
MD-F, MD-V-2

Compliant with highly corrosive / viscous liquids High-end compact magnetic drive pumps Most chemicals can be handled including strong acid/alkaline. High corrosion-resistance Viscosity responsiveness The combination of the MD-F series with CFRETFE wet ends The MD-F series is designed to pump highly viscous liquids and the MD-V series with CFRPVDF wet ends covers most such as strong acid. Three types of impellers are selectable chemicals including strong acid/alkaline. according to liquid viscosity. MD-15F(X/Y)·30F(X/Y) • Max Discharge capacity 9 - 13 l/min 3-8m • Max Discharge head 1 MD-55F(X/Y)·100F(X/Y)...

 Open the catalog to page 2
MD-F, MD-V-3

IWAKI MAGNETIC DRIVE PUMPS Leak free Easy maintenance Magnetically-driven seal-less pumps are free from leak problems The pump unit is comprised of a small number of subunits, so and the need of seal replacement. This feature and its compact that maintenance is significantly eased. nature offer the best fit in built-in applications. md-15rV*20rzV*30(r/rz)V fT! md- 70(r/rz)V ™ • Max Discharge capacity 10 - 32 l/min • Max Discharge capacity 40 - 86 l/min • Max Discharge head 2.4 - 8.0 m • Max Discharge head 6.7 - 14.3 m

 Open the catalog to page 3
MD-F, MD-V-5

IWAKI MAGNETIC DRIVE PUMPS Construction Motor Drive magnet The 6- or 8-pole high power ferrite magnet drives the impeller over the rear casing. Rear casing O ring CFRETFE single-piece rear casing of the MD-F and CFRPVDF single-piece rear casing of the MD-V. The bearing is placed at the bottom, supporting the spindle. Impeller Spindle MD-F CFRETFE single-piece closed impeller. Three impeller types (X/Y) are available according to specific gravity. Front casing MD-F CFRETFE injection mold of the safety thread connection type MD-V CFRPVDF hose connection is available as well as thread connection....

 Open the catalog to page 5
MD-F, MD-V-6

md-15F(x/y)*30F(x/y) • Range of Max. discharge capacity: 9 - 13 L/min • Range of Max. discharge head: 3 - 8 m • Temperature range: 0 - 80°C (Contact us for applications below zero.) • Limit of viscosity: 30 mPa-s (at 1 S.G.) • Ambient temperature: 0 - 40°C • Motor type: Capacitor-run induction motor Pump identification Material of O ring No mark: FKM (Standard) E: EPDM (Special order) Motor 220/240: 220/240 single Iliustiation shows model MD-30F Impeller X: Low S.G. type Y: Middle S.G. type

 Open the catalog to page 6
MD-F, MD-V-7

IWAKI MAGNETIC DRIVE PUMPS MD-F MD-V md-55F(x/y)* 100F(x/y) c tff r Range of Max. discharge capacity: 60 - 125 L/min Range of Max. discharge head: 5.4 - 10.5 m • Temperature range: 0 - 80°C (Contact us for applications below zero.) • Limit of viscosity: 30 mPa-s (at 1 S.G.) • Ambient temperature: 0 - 40°C Pump identification Note: Specify the pump model and power specification at an inquiry phase. Iliustiation shows model MD-100F Available with IEC frame motors This type of unit allows the pumps to be supplied with numerous motor options.

 Open the catalog to page 7
MD-F, MD-V-8

• Temperature range: 0 - 80°C (Contact us for applications below zero.) • Limit of viscosity: 30 mPa-s (at 1 S.G.) • Ambient temperature: 0 - 40°C • Motor type: Capacitor-run induction motor Note: The union field shows the nominal diameter of the applicable VP vinyl chloride hose. Heat resistance of the standard union is 0 - 55°C Pump identification Impeller CFRPVDF Front casing CFRPVDF PTFE / CFRPPS Alumina ceramic Type R: Standard type RZ: High head type Material of O ring No mark: FKM (Standard) E: EPDM (Special order) IIIustlation shows model MD-30RZV Note: Material of bearing for MD-20RZV...

 Open the catalog to page 8
MD-F, MD-V-9

md-70(r/rz)VRange of Max. discharge capacity: 40 - 86 L/min Range of Max. discharge head: 6.7 - 14.3 m Specifications (50Hz) • Temperature range: 0 - 80°C (Contact us for applications below zero.) • Limit of viscosity: 30 mPa-s (at 1 S.G.) • Ambient temperature: 0 - 40°C Note: The union field shows the nominal diameter of the applicable VP vinyl chloride hose. Heat resistance of the union is 0 - 55°C Pump identification Thrust ring Alumina ceramic Bearing PTFE IMustlation shows model MD-70RV Note: Specify the pump model and power specification at an inquiry phase. Note: Material of bearing...

 Open the catalog to page 9
MD-F, MD-V-10

IWAKI MAGNETIC DRIVE PUMPS Special accessories • Union joint Special-purpose union joints are available to cope with three types (13mm, 16mm and 20mm dia.) of piping. Tight sealing O-rings are used to prevent thread damage caused by over-tightening. Specifications Model IWAKI CO., LTD. 6-6 Kanda-Sudacho 2-chome Chiyoda-ku Tokyo 101-8558 Japan TEL : (81)3 3254 2935 FAX : 3 3252 8892 EUROPE ASIA / OCEANIA / NORTH AMERICA / SOUTH AMERICA European office : IWAKI Europe GmbH Holland : IWAKI Europe (NL Branch) Belgium : IWAKI Belgium N.V. Denmark : IWAKI Nordic A/S Finland : IWAKI Suomi...

 Open the catalog to page 10

All IWAKI Europe GmbH catalogs and technical brochures

  1. TC-X

    28  Pages

  2. IX-B

    8  Pages

  3. MEK

    5  Pages

  4. MMP

    2  Pages

  5. MP series

    2  Pages

  6. MTFO

    2  Pages

  7. IX-C/D

    12  Pages

  8. NRD/RD

    4  Pages

  9. SMX-F

    8  Pages

  10. EJ-R

    2  Pages

  11. EWN-W

    2  Pages

  12. V

    8  Pages

  13. EWN-Y-A & EFS

    2  Pages

  14. Serie MDW

    8  Pages

  15. MDE

    8  Pages

  16. MX

    8  Pages

  17. MDM

    5  Pages

  18. MXM

    5  Pages

  19. SMX

    8  Pages

  20. RD-40

    2  Pages

  21. EWN-A

    2  Pages

  22. EWN-Y

    8  Pages

  23. MDM NP

    8  Pages

  24. HRP

    2  Pages

  25. FW/-H

    12  Pages

  26. Serie YMD

    8  Pages

  27. Serie CFD

    12  Pages

  28. Serie FA

    12  Pages

  29. Air pumps

    8  Pages

  30. Serie MDT

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.