1. Catalogs
  2. IWAKI Europe GmbH
  3. EH-E Electromagnetic metering pumps

EH-E Electromagnetic metering pumps

EH-E Electromagnetic metering pumps

EH-E Electromagnetic metering pumps

Product catalog summary
Overview: The IWAKI Electromagnetic Metering Pump EH-E Series is designed for compactness and efficiency, achieving a maximum flow rate of 1.25 L/min. It integrates advanced pump and electronics technology, featuring a microcomputer-controlled system for versatile operation modes.
Specifications: The pump allows for stroke length adjustments between 20% and 100% and stroke rates from 0 to 360 spm, offering a wide range of flow rates. It is powered by a 48W drive unit and supports various power supply voltages (AC100/110/115V and AC220/230/240V).
Controller Functions: The built-in microcomputer enables four operational modes: manual, proportional control, pulse control, and count control. These modes are selectable via keys, allowing for precise control based on external signals.
Construction and Materials: The pump features a water- and dust-proof structure with a reinforced plastic frame (GFRPP) and is resistant to corrosion. The pump head materials include PVC, GFRPP, PVDF, and SUS, with other wetted parts made from corrosion-proof materials like Hastelloy C276 and PTFE.
Operational Modes:
  • Manual Mode: Stroke rate adjustable from 0 to 360 spm.
  • Proportional Control Mode: Stroke rate controlled by external DC0-20mA signals.
  • Pulse Control Mode: Division control based on external pulse signals, adjustable from 1 to 999 pulses.
  • Count-Control Mode: Count-control operations with pulse input storage capability up to 255 pulses.
Safety and Compliance: Users are advised to read the instruction manual carefully for safe operation. The product may require an export license due to international export control regulations.
Additional Information: The document includes detailed specifications for different models (EH-E31, E36, E46, E56) and their respective capacities, discharge pressures, and temperature ranges. It also provides dimensions and connection details for various types.
See more

Catalog excerpts

EH-E Electromagnetic metering pumps-1

IWAKI ELECTROMAGNETIC METERING PUMPS Solutions for chemical handling applications

 Open the catalog to page 1
EH-E Electromagnetic metering pumps-2

Electromagnetic Metering Pump EH Series features not only compact, but also can achieve a maximum flow rate of 1.25 L/min. The EH-E pump's controller includes a microcomputer that enables a single pump to provide not only manual operations, but also automatically controlled operations based on various input signals (current and pulse signals). 'TfiOKE LENGTH High resolution The discharge volume is adjusted in terms of stroke length and rate. The stroke length can be adjusted between 20% and 100%, and the stroke rate can be set between 0 and 360 spm, which enables the EH-E pump to provide a wide range...

 Open the catalog to page 2
EH-E Electromagnetic metering pumps-3

Functions of the controller Manual mode Stroke rate can be increased or decreased by 1-spm anywhere within the range 0 to 360 spm, and is able to set either during operation or stop. Proportional control mode The stroke rate can be proportionally controlled based on external DC0-20mA signals. Select an input signal by means of the keys. Count-control mode The EH-E pump performs count-control operations in response to external pulse signals. The pump provides (n) times shots per pulse input. Set the number (n) between 1 and 999 by means of the keys. If next pulse is input before a set number of...

 Open the catalog to page 3
EH-E Electromagnetic metering pumps-4

IWAKI ELECTROMAGNETIC METERING PUMPS Specifications of pump Model • The max. discharge value in the table above represents the performance measured with clean water under the max. discharge pressure. Actual discharge may increase if operation is conducted at a lower pressure. • Set the discharge pressure at 0.12 MPa or higher to prevent over-feeding trouble. For E56, it should be 0.05 MPa or higher. If the pressure is to be lower than these levels, make sure to use a check valve or a back pressure valve, which is supplied as an optional item. https://www.iwaki.de IWAKI Europe GmbH, Siemensring...

 Open the catalog to page 4

All IWAKI Europe GmbH catalogs and technical brochures

  1. TC-X

    28  Pages

  2. IX-B

    8  Pages

  3. MEK

    5  Pages

  4. MMP

    2  Pages

  5. MP series

    2  Pages

  6. MTFO

    2  Pages

  7. IX-C/D

    12  Pages

  8. NRD/RD

    4  Pages

  9. SMX-F

    8  Pages

  10. EJ-R

    2  Pages

  11. EWN-W

    2  Pages

  12. V

    8  Pages

  13. EWN-Y-A & EFS

    2  Pages

  14. Serie MDW

    8  Pages

  15. MDE

    8  Pages

  16. MX

    8  Pages

  17. MDM

    5  Pages

  18. MXM

    5  Pages

  19. SMX

    8  Pages

  20. RD-40

    2  Pages

  21. EWN-A

    2  Pages

  22. EWN-Y

    8  Pages

  23. MDM NP

    8  Pages

  24. MD-F, MD-V

    10  Pages

  25. HRP

    2  Pages

  26. FW/-H

    12  Pages

  27. Serie YMD

    8  Pages

  28. Serie CFD

    12  Pages

  29. Serie FA

    12  Pages

  30. Air pumps

    8  Pages

  31. Serie MDT

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.