IT8300 Regenerative DC Electronic Load
12Pages

{{requestButtons}}

Catalog excerpts

IT8300 Regenerative DC Electronic Load - 1

YOUR POWER TESTING SOLUTION APPLICATIONS ■ DC/DC converters ■ Large capacity battery ■ Motors, fuses, relays ■ Natural energy ■ High-power DC power supply test ■ Fuel cell toting SoUd^_

Open the catalog to page 1
IT8300 Regenerative DC Electronic Load - 2

IT8300 Series Regenerative DC Electronic Load ITECH newly launched IT8300 Regenerative DC Electronic Load, it not only can simulate various load characteristics, but also can feed power back to grid without pollution. IT8300 series unique regenerative function can convert the absorbed DC power into AC power and feed it back to local grid. This eliminates the usual heat dissipation to a minimum and saves energy costs, adapts requirements of global energy-saving and emission reduction at the same time. IT8300 adopts high power density design, e.g. for 3 U size, it can absorb power up to 10.5...

Open the catalog to page 2
IT8300 Regenerative DC Electronic Load - 3

Current Power Size Your Power Testing SolutionIT8300 Series Regenerative DC Electronic Load 170A 340A 510A 1020A 1530A 2040A 2550A 3060A 3570A Applications ■ Discharge testing for different types of batteries (lead, lithium, power and energy storage batteries) ■ The virtual load test of natural energy (solar cell array, wind power generation) ■ Aging life testing for AC/DC, DC/DC converters ■ Aging testing for motor, fuse and relay under automobile high voltage (e.g., 36 v, 42 v) and small motor testing ■ Security testing for mechanical systems with large capacity battery (e.g. agv, health...

Open the catalog to page 3
IT8300 Regenerative DC Electronic Load - 4

Your Power Testing Solution IT8300 Series Regenerative DC Electronic Load Ultra high power regeneration efficiency up to about 95%90% IT8300 series regenerative DC electronic load is different from other conventional consumed loads, regenerative function is the most important feature of IT8300 series. It can regenerate power to grid and provides low heat dissipation, which will be converted with an efficiency of approximately 95%. This way of energy regeneration helps to lower energy costs and avoids expensive cooling systems, and also reduces the noise. Input Power IT8332(800V/63A/10.5KW)...

Open the catalog to page 4
IT8300 Regenerative DC Electronic Load - 5

Your Power Testing Solution IT8300 Series Regenerative DC Electronic Load List function IT8300 series regenerative DC electronic load provides list mode, it can complete the complex arbitrary current change mode accurately and fast, and can synchronize with internal or external signals to complete multi-level loading precision test, which greatly save cost for customers. By editing the step value, pulse width and the slope of each step, IT8300 can generate a variety of complex sequences and help users to complete various loading waveforms test. In the CC mode, IT8300 series can set rising...

Open the catalog to page 5
IT8300 Regenerative DC Electronic Load - 6

Your Power Testing Solution IT8300 Series Regenerative DC Electronic Load Specification IT8311 Model Input voltage Input rating Input current ( 0~40 ℃) Input power Output voltage range Output frequency range Maximum output current(rms) Power Factor Harmonic THDI Anti-islanding protection active anti-islanding protection active anti-islanding protection Current Readback Voltage Readback Power Readback Input readback Output parameters Max. input voltage full load efficiency 92.5% active anti-islanding protection Note:Resistance readback range IT8311 Lower limit...

Open the catalog to page 6
IT8300 Regenerative DC Electronic Load - 7

Your Power Testing Solution IT8300 Series Regenerative DC Electronic Load Specification IT8341 Input voltage Input rating Input current ( 0~40 ℃) Input power CC mode Range Resolution Output voltage range Output frequency range Maximum output current (rms) Power Factor Harmonic THDI Anti-islanding protection active anti-islanding protection active anti-islanding protection active anti-islanding protection Current Readback Voltage Readback Power Readback Input readback Output parameters Max. input voltage full load efficiency 92.5% efficiency other Note:Resistance readback range IT8341 Lower...

Open the catalog to page 7
IT8300 Regenerative DC Electronic Load - 8

Your Power Testing Solution IT8300 Series Regenerative DC Electronic Load Specification IT8371 Model Input voltage Input rating Input current ( 0~40 ℃) Input power Output voltage range Output frequency range Maximum output current (rms) Power Factor Harmonic THDI Anti-islanding protection active anti-islanding protection active anti-islanding protection Current Readback Voltage Readback Power Readback Input readback Output parameters active anti-islanding protection Max. input voltage full load efficiency 92.5% Note:Resistance readback range IT8371 Lower limit...

Open the catalog to page 8
IT8300 Regenerative DC Electronic Load - 9

Your Power Testing Solution IT8300 Series Regenerative DC Electronic Load Specification Model Input voltage Input rating Input current ( 0~40 ℃) Input power Voltage Readback Power Readback Current Readback Input readback Output parameters Output voltage range Output frequency range Maximum output current (rms) Power Factor Harmonic THDI Anti-islanding protection active anti-islanding protection active anti-islanding protection active anti-islanding protection Max. input voltage full load efficiency 94.5% efficiency other Note:Resistance readback range IT8371

Open the catalog to page 9
IT8300 Regenerative DC Electronic Load - 10

Your Power Testing Solution IT8300 Series Regenerative DC Electronic Load Specification IT8342 Model Input voltage Input rating Input current ( 0~40 ℃) Input power Resolution Accuracy Output voltage range Output frequency range Maximum output current (rms) Power Factor Harmonic THDI Anti-islanding protection active anti-islanding protection active anti-islanding protection active anti-islanding protection Current Readback Voltage Readback Power Readback Max. input voltage full load efficiency 94.5% Input readback Output parameters efficiency other Note:Resistance readback range IT8342

Open the catalog to page 10
IT8300 Regenerative DC Electronic Load - 11

Your Power Testing Solution IT8300 Series Regenerative DC Electronic Load Specification Model Input voltage Input rating Input current ( 0~40 ℃) Input power Resolution Accuracy Current Readback Voltage Readback Power Readback Input readback Output parameters Output voltage range Output frequency range Maximum output current (rms) Power Factor Harmonic THDI Anti-islanding protection active anti-islanding protection active anti-islanding protection active anti-islanding protection Max. input voltage full load efficiency 94.5% efficiency other Note:Resistance readback range IT8371

Open the catalog to page 11

All ITECH ELECTRONIC CO. catalogs and technical brochures

  1. IT-M3900D

    12 Pages

  2. IT8900

    12 Pages

  3. IT8912E

    8 Pages

  4. IT6300

    2 Pages