IT-M3900D
12Pages

{{requestButtons}}

Catalog excerpts

IT-M3900D - 1

High power DC power supply

Open the catalog to page 1
IT-M3900D - 2

High power DC power supply IT-M3900 series integrates the features of a DC power supply, a bi-directional power supply, a source and load system, and a regenerative electronic load in one. It keeps the advantages of high power density and architecture design of M series, power up to 6kw, current up to 510A, and voltage up to 1500V within one 1U unit, effectively reducing the equipment occupation space and cabinet time. wide-range models could meet different test requirements while matching with multi-functional, high energy-saving, high-safety, and high-stability product design, let the...

Open the catalog to page 2
IT-M3900D - 3

Your Power Testing Solution IT-M3900D High power DC power supply *This information is subject to change without notice. Electrolytic plating Water treatment, surface coating, plating 5G Communications & Data Centre Server power supply, UPS inverter unit Semiconductor field Ion injection, MOCVD power supply Industrial component Fuses, automotive connector, current sensor

Open the catalog to page 3
IT-M3900D - 4

Your Power Testing Solution IT-M3900D High power DC power supply High power density, compact design ITECH has always adhered to the design concept of high power density to help users optimize the test solutions. The IT-M3900D series adopts a compact structure design to effectively save rack space, and provide up to 6kW power output in a 1U chassis, up to 12kW power output in a 2U chassis, which makes the entire portfolio of ITECH high power density series more complete and comprehensive. Other power supplies Wide range output There are 25 models included in IT-M3900C series. The output...

Open the catalog to page 4
IT-M3900D - 5

Your Power Testing Solution IT-M3900D High power DC power supply CC&CV priority function CC/CV priority can continue to help users solve various severe problems in long-term test applications to make applications that require high-speed power or non-overshoot more flexible.The CC&CV priority function of IT-M3900D allows the user to select the response speed and the loop working mode of the CC/CV loop to determine whether the output is high-speed voltage mode or non-overshoot current mode, which is suitable for high-power integrated circuit testing, charging and discharging testing, power...

Open the catalog to page 5
IT-M3900D - 6

Your Power Testing Solution IT-M3900D High power DC power supply High efficiency parallel connection technology Considering the user's convenience and versatility , IT-M3900d can The parameters will not change after parallel connection Calibration is not requested after parallel connection Optical fiber transfer between master and slave, guarantee perfect performance of anti-interference Adopt Optical fiber isolation technology, effective protection of the device and DUT use master/slave control mode to parallel 6 units or more. Meanwhile ITECH patented fiber optic parallel technology fully...

Open the catalog to page 6
IT-M3900D - 7

Your Power Testing Solution IT-M3900D High power DC power supply 2 DC output terminals of the power supply 3 Interface for optional accessories interface of outer ring optical fiber (TX and RX) 9 AC power input terminals (L1, L2, L3, and PE) Optional Accessories IT15U cabinet Optical fiber cable kit Connection between the units in a cabinet Cabinet rack mount Kit Cabinet rack mount installation Anti-reverse protection unit 750V/250A avoid reverse connection Anti-reverse protection unit 750V/400A avoid reverse connection Anti-reverse protection unit 900V/400A avoid reverse connection Anti...

Open the catalog to page 7
IT-M3900D - 8

Your Power Testing Solution IT-M3900D High power DC power supply Series Resistance (CV priority mode) Voltage Peak Value Readback Drift Temperature Voltage Coefficient Current Rising Time (no load) Rising Time (full load) Falling Time (no load) Falling Time (full load) Dynamic Response Time Power Factor Current Harmonic Programming Response Time Withstand Voltage (DC to ground) Withstand Voltage (AC to ground) Input Rating Series Resistance (CV priority mode) Input Resolution Series Resistance (CV priority mode) Readback Resolution Setup Accuracy Readback Accuracy Ripple Input Drift...

Open the catalog to page 8
IT-M3900D - 9

Your Power Testing Solution IT-M3900D High power DC power supply Specification Voltage Series Resistance (CV priority mode) Series Resistance (CV priority mode) Voltage Peak Value Readback Drift Temperature Voltage Coefficient Current Rising Time (no load) Rising Time (full load) Falling Time (no load) Falling Time (full load) Dynamic Response Time Power Factor Current Harmonic Programming Response Time Withstand Voltage (DC to ground) Withstand Voltage (AC to ground) Input Rating Input Resolution Series Resistance (CV priority mode) Readback Resolution Setup Accuracy Readback Accuracy...

Open the catalog to page 9
IT-M3900D - 10

Your Power Testing Solution IT-M3900D High power DC power supply Series Resistance (CV priority mode) Voltage Peak Value Readback Drift Temperature Voltage Coefficient Current Rising Time (no load) Rising Time (full load) Falling Time (no load) Falling Time (full load) Dynamic Response Time Power Factor Current Harmonic Programming Response Time Withstand Voltage (DC to ground) Withstand Voltage (AC to ground) Input Rating Series Resistance (CV priority mode) Input Resolution Series Resistance (CV priority mode) Readback Resolution Setup Accuracy Readback Accuracy Ripple Input Drift...

Open the catalog to page 10
IT-M3900D - 11

Your Power Testing Solution IT-M3900D High power DC power supply Specification IT-M3906D-1500-12 Voltage Input Rating Series Resistance (CV priority mode) Input Resolution Series Resistance (CV priority mode) Voltage Setup Accuracy Current Power Readback Resolution Series Resistance (CV priority mode) Voltage Peak Value Readback Drift Temperature Voltage Coefficient Current Rising Time (no load) Rising Time (full load) Falling Time (no load) Falling Time (full load) Dynamic Response Time Readback Accuracy Ripple Input Drift Temperature Coefficient Power Regulation Rate Load Regulation Rate...

Open the catalog to page 11
IT-M3900D - 12

YOUR POWER TESTING SOLUTION This information is subject to change without notice.For more information, please contact ITECH. Add: No.918, Zhongzheng Rd., Zhonghe Dist., New Taipei City Add: No.108, XiShanqiao Nanlu, Nanjing city, 210039, China Add: No.150, Yaonanlu, Meishan Cun, Nanjing city, 210039, China E-mail: info@itechate.com ITECH Facebook ITECH LinkedIn

Open the catalog to page 12