DIESEL GENERATOR 50HZ 3Phase 10∼2475KVA
1 /10Pages

DIESEL GENERATOR 50HZ 3Phase 10∼2475KVA

DIESEL GENERATOR 50HZ 3Phase 10∼2475KVA
1 /10Pages

Catalog excerpts

DIESEL GENERATOR 50HZ 3Phase 10∼2475KVA-3

ill Bays I Sally I Reliable I Stability BBBBBB Perkins PERKINS ENGINE SERIES Engine Advanced design and precise manufacturing ensure low fuel consumption. Strong power and perfect low speed performance. Excellent start perfomance,Reliable running quality,less spare parts involved provides easy maintenance and repair job. Fuel injector and pump were tested fully in Various environments,which provide excellent

 Open the catalog to page 3
DIESEL GENERATOR 50HZ 3Phase 10∼2475KVA-4

§H Perkins PERKINS ENGINE SERIES Technical Specification Prime Power

 Open the catalog to page 4
DIESEL GENERATOR 50HZ 3Phase 10∼2475KVA-6

§§ Perkins PERKINS ENGINE SERIES Technical Specification

 Open the catalog to page 6
DIESEL GENERATOR 50HZ 3Phase 10∼2475KVA-8

ComApControl System Support engine and alterantor monitoring, measurement and protection.This is long-running and back-up unit to integrate the best way to controlo support Modbus standard, modem, RS232_ RS485. USB and internet,, Measurement, displayment CONTROLLER WITH SUPPORT FOR EFI ENGINE AMF 25 p 3 configurable analog inputs o magnetic pickup input p D+ preexcitation terminal p 6 binary inputs P 6 binary outputs p GCB control p CAN with J1939 support P extension modules capability P event and performance log p 3 configurable analog inputs p magnetic pickup input p D+ preexcitation terminal...

 Open the catalog to page 8
DIESEL GENERATOR 50HZ 3Phase 10∼2475KVA-9

Synchronizing controller # Essential Iced is fed by two mains feeders during normal operation to achieve maximum rale to by of the power delivery. Bus-tie breaker i.BTBl is dosed • Complex switching algorithm running in external PLC defnes which breakers are opened and which are dosed independent or availability of two mains and gen-sets. • Reverse synchronizing on both feeders and on bus—tie breaker is aocomptshed by 5 IntelMansNT modules oontjolad by external PLC. # Active and reactive load-sharing can operate in two modes: Sharing the load between al running gen-sets if BTB is closed Sharing...

 Open the catalog to page 9
DIESEL GENERATOR 50HZ 3Phase 10∼2475KVA-10

fffgjhlizar AH Olfi I Salty I bailable I Stability * * # 50HZ 3 Phase 10-2475 KVA DIESEL ENGINE GENERATORBefore you buy our generator sets. You should tell us... What is the situation for the power supplying there? A. Power supplying well, just worry about power supply bureau inspection monthly that lead to power off in the hotel (or restaurant, bank, shop & store etc.) □ B. Power supplying bad, power failure often □ C. No power supplying, such as in island or very wild field □ What is the local voltage there ? 115/230V □ 220V □ 380V □ 400V □ 440V □ What is the biggest power load should be for...

 Open the catalog to page 10