1. Catalogs
  2. ITALWEBER
  3. Surge protective devices

Surge protective devices

Surge protective devices
1 / 68 PagesView full catalog

Surge protective devices

Product catalog summary
Introduction to Overvoltages
Overvoltages are abnormal increases in network voltage, caused by factors such as lightning, circuit operations, and temporary faults. Primary protection involves a Lightning Protection System (LPS), while secondary protection uses Surge Protective Devices (SPDs) to guard against transient overvoltages.
Characteristics of Surge Protective Devices (SPD)
SPDs act as open circuits under normal conditions and become conductive during overvoltages, directing current to earth. They must respond in nanoseconds and revert to open circuit post-event. Types include varistor-based SPDs with low response times and Gas Discharge Tube (GDT) SPDs with high discharge capacity.
Classification and Standards
SPDs are classified by international standards: Class I for direct lightning strikes and Class II for remote strikes or circuit commutations. The protection level Up must be less than the impulse withstand level of the protected equipment. IEC 60664 defines four impulse withstand categories for low voltage equipment.
Product Specifications
Specifications include maximum terminal screw torque, terminal cross section, fixing on DIN rail, housing material, and degree of protection. Reference standards include IEC 61643-11.
Grounding Systems
Different grounding systems include TT, TN, and IT systems, each with specific configurations for connecting neutral and masses to ground.
SPDs for Photovoltaic Plants
SPDs protect against direct and indirect lightning strikes. For DC side protection, SPDs should be installed on each string or downstream of string parallels. For AC side, SPDs protect inverters from network surges.
Applications in Various Sectors
SPDs are crucial in sectors like oil and gas, data centers, and electric vehicle charging stations to protect sensitive electronic components from overvoltages.
Technical Specifications
Detailed specifications for various SPD models include nominal and maximum discharge currents, response times, operating temperature ranges, and compliance with IEC standards.
Conclusion
Proper selection and installation of SPDs are critical for protecting photovoltaic systems, wind turbines, and electric vehicle charging stations from overvoltages and lightning-induced damages.
See more

Catalog excerpts

Surge protective devices-1

Dispositivi di protezione contro le sovratensioni Surge protective devices

 Open the catalog to page 1
Surge protective devices-2

LIMITATORI E SCARICATORI DI SOVRATENSIONE PER SISTEMI DI BASSA E MEDIA TENSIONE E PER LINEE DATI SURGE ARRESTERS FOR LOW AND MEDIUM VOLTAGE POWER SYSTEMS AND FOR DATA / SIGNAL PROTECTION Con il continuo incremento dell’importanza del ruolo dell’elettronica e dei microprocessori, che caratterizza ormai quasi ogni aspetto delle nostre vite e che in buona misura ci consente di godere di molte “comodità”, impensabili anche solo pochi anni fa, diventa fondamentale disporre di adeguati dispositivi atti a proteggere tali importanti e delicate tecnologie e, in ultima analisi, anche il nostro stesso attuale...

 Open the catalog to page 2
Surge protective devices-3

Introduzione alle sovratensioni Introduction to overvoltages Scaricatori classe I - Serie Standard Class I SPDs - Standard series Scaricatori classe II - Serie Standard Class II SPDs - Standard series Scaricatori classe III - Serie Standard Class III SPDs - Standard series Scaricatori classe I - Serie ITSAFE Class I SPDs - ITSAFE series Scaricatori classe II - Serie ITSAFE Class II SPDs - ITSAFE series Scaricatori per impianti fotovoltaici SPDs for photovoltaic plants Scaricatori per impianti eolici SPDs for wind turbines plants Scaricatori per linee dati SPDs for data-signal lines With the continual...

 Open the catalog to page 3
Surge protective devices-4

INTRODUZIONE ALLE SOVRATENSIONI Le sovratensioni possono essere definite come un aumento anomalo della tensione di rete, avente carattere impulsivo oppure oscillatorio smorzato, che si sovrappone alla normale tensione. Le cause di sovratensione negli impianti elettrici possono essere varie: sovratensioni di origine atmosferica (fulmini), sovratensioni dovute a manovre di apertura o commutazione di circuiti, sovratensioni temporanee dovute a guasti, ecc. Normalmente, quando si parla di sovratensioni, si fa riferimento alle scariche causate dai fulmini, che si possono abbattere direttamente sulle...

 Open the catalog to page 4
Surge protective devices-5

CARATTERISTICHE DEGLI SCARICATORI DI SOVRATENSIONE In assenza di sovratensione nessuna corrente verso terra deve circolare attraverso la protezione. Lo scaricatore si comporta quindi come un circuito aperto, mantenendo l’isolamento tra i conduttori attivi e la terra. All’apparire di una sovratensione che supera la soglia di tensione ammissibile per l’impianto da proteggere, la protezione deve invece diventare rapidamente conduttrice drenando verso terra la corrente creata dalla sovratensione, e limitando la tensione a valori accettabili (livello di protezione Up). Il tempo di risposta della protezione...

 Open the catalog to page 5
Surge protective devices-6

CARATTERISTICHE DEGLI SCARICATORI DI SOVRATENSIONE CHARACTERISTICS OF THE SURGE PROTECTIVE DEVICES (SPD) - SPD with Gas Discharge Tube (GDT): when there is no overvoltage they have a very high impedance, that is reduced very quickly when the voltage increases. They are made with a tube containing a gas that is ionized by the overvoltage. The advantages are the high capacity of current discharge and the leakage current equal to zero. The disadvantages are the relatively high response time and the fact that, after the overvoltage, the gas keeps its ionization for a certain period of time and a...

 Open the catalog to page 6
Surge protective devices-7

SURGE PROTECTIVE DEVICES ITPRO1 - CLASS I+II SCARICATORI DI SOVRATENSIONE ITPRO1 - CLASSE I+II Classe di prova IEC / VDE Category IEC / VDE Corrente di scarica nominale (onda 8/20) In Nominal discharge current (8/20 wave) In Corrente di scarica massima (onda 8/20) Imax Maximum discharge current (8/20 wave) Imax Short circuit withstand current Response time Temperatura operativa Temperature range Forza serraggio terminali Terminal screw torque Sezione cavi Terminal cross section Materiale corpo termoplastico Housing thermoplastic material Reference standards Dotati di protezione termica integrata...

 Open the catalog to page 7
Surge protective devices-8

SURGE PROTECTIVE DEVICES ITPRO1 - CLASS I+II SCARICATORI DI SOVRATENSIONE ITPRO1 - CLASSE I+II Sistema di distribuzione di energia: TN-S monofase / Single phase TN-S connection type Codice Code Tensione continuativa Operating voltage AC/DC UC (V) Tipo Type Livello di protezione Protection level UP Corrente d’impulso (onda 10/350) Impulse current (10/350 wave) lIMP Laghezza (moduli DIN) Width (DIN modules) Contatto segnalazione Remote contact Sistema di distribuzione di energia: TN-C trifase / Three phase TN-C connection type Codice Code Tensione continuativa Operating voltage AC/DC UC (V) Tipo...

 Open the catalog to page 8
Surge protective devices-9

Sistema di distribuzione di energia: TT trifase / Three phase TT connection type Codice Code Tensione continuativa Operating voltage AC/DC UC (V) Livello di protezione Protection level UP Corrente d’impulso (onda 10/350) Impulse current (10/350 wave) lIMP Laghezza (moduli DIN) Width (DIN modules) Contatto segnalazione Remote contact Sistema di distribuzione di energia: TN-S trifase / Three phase TN-S connection type Codice Code Tensione continuativa Operating voltage AC/DC UC (V) Tipo Type Livello di protezione Protection level UP Corrente d’impulso (onda 10/350) Impulse current (10/350 wave)...

 Open the catalog to page 9
Surge protective devices-10

SURGE PROTECTIVE DEVICES ITPRO2 - CLASS I+II SCARICATORI DI SOVRATENSIONE ITPRO2 - CLASSE I+II Classe di prova IEC / VDE Category IEC / VDE Corrente di scarica nominale (onda 8/20) In Nominal discharge current (8/20 wave) In Corrente di scarica massima (onda 8/20) Imax Maximum discharge current (8/20 wave) Imax Short circuit withstand current Response time Temperatura operativa Temperature range Forza serraggio terminali Terminal screw torque Sezione cavi Terminal cross section Materiale corpo termoplastico Housing thermoplastic material Reference standards Dotati di protezione termica integrata...

 Open the catalog to page 10
Surge protective devices-11

Sistema di distribuzione di energia: TT monofase / Single phase TT connection type Codice Code Tensione continuativa Operating voltage AC/DC UC (V) Livello di protezione Protection level UP Corrente d’impulso (onda 10/350) Impulse current (10/350 wave) lIMP Laghezza (moduli DIN) Width (DIN modules) Contatto segnalazione Remote contact Livello di protezione Protection level UP Corrente d’impulso (onda 10/350) Impulse current (10/350 wave) lIMP Laghezza (moduli DIN) Width (DIN modules) Contatto segnalazione Remote contact Sistema di distribuzione di energia: TN-C trifase / Three phase TN-C connection...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.