1. Catalogs
  2. ITALWEBER
  3. ETIMAT - Modular devices for protection and control

ETIMAT - Modular devices for protection and control

ETIMAT - Modular devices for protection and control
1 / 48 PagesView full catalog

ETIMAT - Modular devices for protection and control

Product catalog summary
Overview: The document provides comprehensive details on the ETIMAT series of modular devices for low voltage electrical circuit protection and control. It includes circuit breakers, residual current circuit breakers, and other essential components for electrical safety and reliability.
Specifications: The ETIMAT series features miniature circuit breakers with breaking capacities of 6 kA and 10 kA, compliant with IEC EN 60898 and IEC EN 60947-2 standards. They are available in single-pole, two-pole, and three-pole configurations, with rated currents from 0.5A to 63A.
Product Features: These modular products are made with high-quality materials, designed for easy installation and long-term reliability, suitable for both residential and industrial applications, providing protection against overcurrents and earth faults.
Certifications: The products are certified by VDE (Germany) and KEMA (Netherlands), ensuring quality and safety.
Key Components: The document details components such as miniature circuit breakers, residual current circuit breakers, add-on blocks, switch disconnectors, and modular contactors, with specific characteristics like tripping curves (B, C, D), rated voltage, and current.
Installation and Usage: Designed for DIN rail mounting, these devices offer features like sealing in both ON and OFF positions, support cable sections from 1-25 mm², and have a maximum torque force of 3 Nm.
Conclusion: The ETIMAT series offers a comprehensive range of modular devices for effective electrical circuit protection and control, backed by international certifications and designed for diverse applications.
Miniature Circuit Breakers (MCBs): The document lists MCBs with specifications including pole configuration, current ratings, RCCB class, and residual current sensitivity.
Switch Disconnectors (SV Series): Compliant with IEC EN 60947-3 standards, available in multiple pole configurations with current ratings from 16A to 125A.
Control Switches: Includes built-in switches, change-over switches, and push-button switches with control lights.
Signal Lights, Transformers, and Sockets: Signal lights in multiple colors, modular transformers with specific voltage and power ratings, and DIN sockets with module numbers and current ratings.
Control Equipment: Includes time relays, twilight switches, and digital time switches with programmable features.
Standards and Mounting: All equipment adheres to relevant EN standards and is designed for DIN rail mounting.
Technical Specifications: Detailed specifications for various components, including rated current, inrush current, breaking capacity, operating temperature, and more.
Accessories: Includes caps for insulated busbars, insulated busbars, pin connection clamps, and wall mounting cabinets.
Sales Organization: Contact information for regional representatives across Italy.
See more

Catalog excerpts

ETIMAT - Modular devices for protection and control-1

Apparecchiature modulari di protezione e comando Modular devices for protection and control

 Open the catalog to page 1
ETIMAT - Modular devices for protection and control-2

Sistema di apparecchiature modulari per la protezione e il comando di circuiti elettrici in Bassa Tensione Modular devices system for the protection and control of Low Voltage electrical circuits Il sistema di apparecchiature modulari di protezione e di comando della serie ETIMAT comprende una gamma completa di interruttori automatici, interruttori differenziali puri, blocchi differenziali, interruttori magnetotermici differenziali, interruttori non automatici, contattori ed altri componenti per il comando e la protezione dei circuiti elettrici. Tutti i prodotti del sistema sono di tipo modulare,...

 Open the catalog to page 2
ETIMAT - Modular devices for protection and control-3

Interruttori magnetotermici Etimat 6 kA Miniature circuit breakers Etimat 6 kA Interruttori magnetotermici Etimat 10 kA Miniature circuit breakers Etimat 10 kA Interruttori magnetotermici Etimat P10 (10 kA) Miniature circuit breakers Etimat P10 (10 kA) Interruttori magnetotermici Etimat P10 QC (10 kA) Miniature circuit breakers Etimat P10 QC (10 kA) Power needs control Interruttori magnetotermici Etimat P10 DC (6 kA) Miniature circuit breakers Etimat P10 DC (6 kA) The ETIMAT series of modular devices is composed by a full range of miniature circuit breakers, residual current circuit breakers,...

 Open the catalog to page 3
ETIMAT - Modular devices for protection and control-4

MInIAture CIrCuIt BreAKers InterruttorI MAGnetoterMICI Norme | Standards: IEC EN 60898 Tensione nominale Correnti nominali Frequenza nominale Potere di interruzione Classe di limitazione Caratteristiche di intervento Sezione cavi di collegamento Coppia di serraggio Larghezza polo Aggancio su guida DIN Piombabile Rated voltage Rated currents Rated frequency Breaking capacity Energy limiting class Tripping characteristics Cable section Torque force Pole width DIN rail mounting Sealing possibility 230V / 400V AC, max 60V DC from 6A to 63A 50/60 Hz 6 kA (CEI EN 60898) 3 B, C, D 1-25 mm2 (1-10 mm2...

 Open the catalog to page 4
ETIMAT - Modular devices for protection and control-5

2 poli (2 moduli diN) | 2 polES (2 diN modulES) Curva B | B characteristic Codice Code Conf. pack. Codice Code Conf. pack. Codice Code Conf. pack. 3 poli (3 moduli diN) | 3 polES (3 diN modulES) Curva B | B characteristic Codice Code Conf. pack. Codice Code Conf. pack. Codice Code Conf. pack. 3 poli + N (4 moduli diN) | 3 polES + N (4 diN modulES) Curva B | B characteristic Codice Code Conf. pack. Codice Code Conf. pack. Codice Code Conf. pack. Gli interruttori della serie ETIMAT 6, nelle curve C e D (escluso tipo 1P+N in un modulo), sono disponibili anche con correnti nominali di 0,5A / 1A /...

 Open the catalog to page 5
ETIMAT - Modular devices for protection and control-6

MInIAture CIrCuIt BreAKers InterruttorI MAGnetoterMICI Norme | Standards: IEC EN 60898 | IEC EN 60947 - 2 Tensione nominale Correnti nominali Frequenza nominale Potere di interruzione Classe di limitazione Caratteristiche di intervento Sezione cavi di collegamento Coppia di serraggio Classe di isolamento Larghezza polo Aggancio su guida DIN Piombabile Rated voltage Rated currents Rated frequency Breaking capacity Energy limiting class Tripping characteristics Cable section Torque force Isolating class Pole width DIN rail mounting Sealing possibility 230V / 400V AC, max 60V DC from 0,5A to 40A...

 Open the catalog to page 6
ETIMAT - Modular devices for protection and control-7

2 POLI (2 MODULI DIN) | 2 POLES (2 DIN MODULES) Conf. Codice ln(A) Peso (Kg) Conf. Pack. Code IJA) Weight (Kg) Pack. 3 POLI (3 MODULI DIN) | 3 POLES (3 DIN MODULES) Conf. Codice I (A) Peso (Kg) Conf. Pack. Code IJA) Weight (Kg) Pack. 3 POLI + N (4 MODULI DIN) | 3 POLES + N (4 DIN MODULES) I INTERRinTORI MAGNETOTERMICI | MINIATURE CIRCUIT BREAKERS ] 7

 Open the catalog to page 7
ETIMAT - Modular devices for protection and control-8

ACCESSORI PER INTERRUTTORI ACCESSORIES FOR MCBs SERIE ETIMAT 6 kA E ETIMAT 10 kA ETIMAT 6 kA AND ETIMAT10 kA SERIES CONTATTIAUSILIARI | AUXILIARY CONTACTS Codice Descrizione N° moduli DIN Conf. Code Description N" DIN modules Pack. Corrente nominale / Rated current: 6A (230V AC) - 1A(110V DC) Sezione cavi di collegamento / Cable section: 1-4 mm; BOBINE DI SGANCIO A LANCIO DI CORRENTE | SHUNT TRIP RELEASES Codice Descrizione N° moduli DIN Conf. Code Description N" DIN modules Pack. Tensione nominale / Rated voltage: 110 - 415V AC Massima corrente d'inserzione / Max inrush current: 3,6A Fissaggio...

 Open the catalog to page 8
ETIMAT - Modular devices for protection and control-9

INTERRUTTORI MAGNETOTERMICI MINIATURE CIRCUIT BREAKERS DIMENSIONI E CARATTERISTICHE TECNICHE DIMENSIONS AND TECHNICAL SPECIFICATIONS CONTATTO AUSILIARIO / AUXILIARY CONTACTS BOBINA Dl SGANCIO / SHUNT TRIP RELEASE CARATTERISTICHE D'INTERVENTO I TRIPPING CHARACTERISTICS Curva d'intervento Test current Tripping time I INTERRUTTORI MAGNETOTERMICI | MINIATURE CIRCUfT BREAKERS \ 9

 Open the catalog to page 9
ETIMAT - Modular devices for protection and control-10

MInIAture CIrCuIt BreAKers InterruttorI MAGnetoterMICI Norme | Standards: IEC EN 60898 | IEC EN 60947 - 2 Tensione nominale Correnti nominali Frequenza nominale Potere di interruzione Classe di limitazione Caratteristiche di intervento Sezione cavi di collegamento Coppia di serraggio Larghezza polo Aggancio su guida DIN Piombabile Rated voltage Rated currents Rated frequency Breaking capacity Energy limiting class Tripping characteristics Cable section Torque force Pole width DIN rail mounting Sealing possibility 230V / 400V AC from 2A to 63A 50/60 Hz 10 kA 3 B, C, D, K 1-25 mm2 max 2 Nm 18 mm...

 Open the catalog to page 10
ETIMAT - Modular devices for protection and control-11

1 polo + N (2 moduli diN) | 1 polE + N (2 diN modulES) Curva B | B characteristic Codice Code Conf. pack. Codice Code Conf. pack. Codice Code Conf. pack. Codice Code Conf. pack. 2 poli (2 moduli diN) | 2 polES (2 diN modulES) Curva B | B characteristic Codice Code Conf. pack. Codice Code Conf. pack. Codice Code Conf. pack. Codice Code Conf. pack. | INTERRUTTORI MAGNETOTERMICI | MINIATURE CIRCUIT BREAKERS

 Open the catalog to page 11
ETIMAT - Modular devices for protection and control-12

MInIAture CIrCuIt BreAKers InterruttorI MAGnetoterMICI 3 poli (3 moduli diN) | 3 polES (3 diN modulES) Curva B | B characteristic Codice Code Conf. pack. Codice Code Conf. pack. Codice Code Conf. pack. Codice Code Conf. pack. 3 poli + N (4 moduli diN) | 3 polES + N (4 diN modulES) Curva B | B characteristic Codice Code Conf. pack. Codice Code Conf. pack. Codice Code Conf. pack. Codice Code Conf. pack. | INTERRUTTORI MAGNETOTERMICI | MINIATURE CIRCUIT BREAKERS |

 Open the catalog to page 12
ETIMAT - Modular devices for protection and control-13

MInIAture CIrCuIt BreAKers InterruttorI MAGnetoterMICI Norme | Standards: IEC EN 60898 | IEC EN 60947 - 2 Tensione nominale Correnti nominali Frequenza nominale Potere di interruzione Classe di limitazione Caratteristiche di intervento Sezione cavi di collegamento Coppia di serraggio Larghezza polo Aggancio su guida DIN Piombabile Rated voltage Rated currents Rated frequency Breaking capacity Energy limiting class Tripping characteristics Cable section Torque force Pole width DIN rail mounting Sealing possibility 230V / 400V AC from 0,5A to 20A 50/60 Hz 10 kA 3 B, C, D, K 1-4 mm2 max 2 Nm 18...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.