General Catalogue EN019
112Pages

{{requestButtons}}

Catalog excerpts

General Catalogue EN019 - 3

INDEX Italvibras Guide to explosive atmospheres / hazardous locations Foot mounted electric vibrators Electric vibrators Electric vibrators with split covers Axial coupling electric vibrators Increased safety electric vibrators Low speed electric vibrators Electric vibrators in stainless steel Electric vibrators with reduced overall size Multi-hole fixing electric vibrator Increased safety multi-hole fixing electric vibrator Explosion proof-electric vibrators Explosion proof screen vibrators Direct current electric vibrators MVSI MVSI-TS MVSI-ACC MVSI-E MVLS MVSS MICRO M3 M3-E CDX MVT/MVTX...

Open the catalog to page 3
General Catalogue EN019 - 4

Italvibras Guide to explosive atmospheres Zone System D DUST Zone 22 MVSI MICRO MVSS-P MVSI MVSI, MTF, MVB, MVB-FLC, VB, MVSS MVSI-E, M3-E, MTF-E, MVB-E, MVB-E-FLC, VB-E MVSI, MTF, MVB, MVB-FLC, VB, MVSS MVSI-E, M3-E, MTF-E, MVB-E, MVB-E-FLC, VB-E Production Quality Assurance Notification Directive 2014/34/UE CESI 00 ATEX 061 Q IECEx Quality Assessment Report n. IT/CES/QAR08.0003 Others certifications: Compliance with regulations TR CU 012/2011 (explosive atmospheres for Eurasian Customs Union) Compliance with Korean Certificatio

Open the catalog to page 4
General Catalogue EN019 - 5

/ hazardous locations Class / Division System CLASS II DUST CLASS II Division 2 MVSI CLASS I Division 1 MVSI-C GAS CLASS I CERTIFICATE FEATURES Class I, Div.1, Groups CD. Class II, Div.1, Groups EFG. T4 /T3C Class I, Div.1, Groups CD. Class II, Div.1, Groups EFG. T4 Class I, Div.2, Groups ABCD. T3C / T3A / T3 MVSI-C, MVSI-TS, MVSI-ACC, MTF-C, MVB-C, VB-C File Number: E129825 Legacy Number: 100948 Master Contract: 161432

Open the catalog to page 5
General Catalogue EN019 - 6

Technical features Power supply Three-phase voltage from 24V to 690V, 50Hz or 60Hz or single-phase 100-130V, 60Hz and 200-240V, 50Hz (single-phase types are supplied without capacitor); suitable for use with an inverter from 20Hz to the base frequency with constant torque load profile. Polarity 2, 4, 6 and 8 standard poles, 10 and 12 poles on request. Conformity with Standards and Regulations Low Voltage Directive 2006/95/EC; ATEX Directive 2014/34/UE; EN/IEC 60034-1, EN/IEC 60079-0, EN/IEC 60079-31, UL 1004-1, CSA C22.2 No.100, NEMA MG-1. Functioning Continual service (S1) at maximum...

Open the catalog to page 6
General Catalogue EN019 - 7

The MVSI series represents the line of reference products for manufacturers of vibrating machines and plants operating in many industrial sectors and is made up of the largest range on the market, with centrifugal force values up to 30500 Kgf (300kN). It is characterized by the continuous technological evolution in view of a continuous improvement in performance. The MVSI series is designed to guarantee high performance in all conditions of use and environment, on page 14 the various surface treatments available are described. Level of protection: Ex tD A21 T...°C IP66 (Ex tb IIIC T...°C...

Open the catalog to page 7
General Catalogue EN019 - 8

2 poles - 3.000/3.600 rpm Three-phase DESCRIPTION MECHANICAL SPECIFICATIONS II2D Temp. class Static moment* kgmm ELECTRICAL SPECIFICATIONS Weight kg Static moment* kgmm

Open the catalog to page 8
General Catalogue EN019 - 9

DIMENSIONAL SPECIFICATIONS (mm) Holes Cable entry thread Holes Type Cable entry thread la/ln = ratio between start-up current and maximum current. ** Slot. Several sizes are available with different mounting bolt patterns. Please contact sales office at Italvibras. General Catalogue 07-2019 Italvibr

Open the catalog to page 9
General Catalogue EN019 - 10

4 poles - 1.500/1.800 rpm Three-phase DESCRIPTION MECHANICAL SPECIFICATIONS II2D Temp. class Static moment* kgmm ELECTRICAL SPECIFICATIONS Weight kg Single-phase II2D Temp. class Static moment* kgmm * Working moment = 2 x static moment.

Open the catalog to page 10
General Catalogue EN019 - 11

DIMENSIONAL SPECIFICATIONS (mm) Holes Cable entry thread Holes Type Cable entry thread ¢ Running capacitor / l Additional capacitor only for start-up. la/ln = ratio between start-up current and maximum current. ** Slot. Several sizes are available with different mounting bolt patterns. Please contact sales office at Italvibras.

Open the catalog to page 11
General Catalogue EN019 - 12

6 poles - 1.000/1.200 rpm Three-phase DESCRIPTION MECHANICAL SPECIFICATIONS II2D Temp. class Static moment* kgmm ELECTRICAL SPECIFICATIONS Weight kg * Working moment = 2 x static moment.

Open the catalog to page 12
General Catalogue EN019 - 13

DIMENSIONAL SPECIFICATIONS (mm) Holes Type Cable entry thread la/ln = ratio between start-up current and maximum current. Several sizes are available with different mounting bolt patterns. Please contact sales office at Italvibras. General Catalogue 07-2019 Italvibras

Open the catalog to page 13
General Catalogue EN019 - 14

8 poles - 750/900 rpm Three-phase DESCRIPTION MECHANICAL SPECIFICATIONS II2D Temp. class Static moment* kgmm ELECTRICAL SPECIFICATIONS * Working moment = 2 x static moment. ¨ CSA certification on request, with feeding

Open the catalog to page 14
General Catalogue EN019 - 15

DIMENSIONAL SPECIFICATIONS (mm) Holes Fig. Cable entry thread la/ln = ratio between start-up current and maximum current. Several sizes are available with different mounting bolt patterns. Please contact sales office at Italvibras. General Catalogue 07-2019 Italvibras

Open the catalog to page 15
General Catalogue EN019 - 16

Surface treatments and available versions for MVSI Series MVSI Technical features Standard painting Electrostatic surface treatment for all external components based on polymerised epoxy polyester powder in oven at 200°C. Good resistance versus corrosion in normal operating conditions. Salt spray tested for 500 hours. MVSI-S Technical features Standard painting with weight covers in stainless steel. Casing and terminal box cover with electrostatic surface treatment based on polymerised epoxy polyester powder in oven at 200°C. Weight covers in stainless steel AISI 304. Excellent resistance...

Open the catalog to page 16
General Catalogue EN019 - 17

MVSI-SI Technical features STEEL IT polyurethane resin coating Casing and terminal box cover have a special polyurethane resin coating with insertion of stainless steel leafing pigment AISI 316L. Weight covers in stainless steel AISI 304. All external hexagonal head screws are of stainless steel quality A2. Coating is USDA approved for being used in the food sector where there is a high risk of accidental contact with processed food. Salt spray tested for 500 hours. Available for all models from all frame sizes. MVSI-BR Technical features Ball burnishing treatment This treatment takes place...

Open the catalog to page 17
General Catalogue EN019 - 18

Technical features Power supply Three-phase voltage from 48V to 690V, 50Hz or 60Hz; suitable for use with an inverter from 20Hz to the base frequency, with constant torque load profile. Polarity 4, 6 and 8 poles. Conformity with Standards and Regulations Low Voltage Directive 2006/95/EC; EN/IEC 60034-1; UL 1004-1, CSA C22.2 No.100, NEMA MG-1. Functioning Continual service (S1) at maximum declared centrifugal force and electric power. Intermittent services are also possible depending on the type of vibrator and the operating conditions. For detailed information contact our technical...

Open the catalog to page 18