Overview: The dV-2 PS is a digital pressure gauge featuring two independent pressure switch outputs. It utilizes KELLER's microprocessor technology for high accuracy, with readings linearized and temperature corrected to achieve 0.2% FS accuracy.
Switching Functions: The device includes two independent solid-state switches for high and low control functions, which are wear-resistant. Switch points are programmable via front panel buttons or through a PC using RS485 and KELLER's software. The switches can operate as make or break contacts, with options for window or hysteresis functions. Status is indicated by an LED on the front panel.
Key Functions:
  • High/Low: Displays maximum and minimum values.
  • Reset: Resets max/min values to current pressure.
  • Zero: Sets a new zero reference to compensate for barometric variations.
  • Switch Configuration: Allows setting of switch points, window, and hysteresis.
  • Units: Pressure can be displayed in bar, MPa, or PSI.
Specifications:
  • Pressure Ranges: Absolute (0-700 bar), Relative (-1-30 bar).
  • Display Resolution: 1 mbar to 100 mbar depending on range.
  • Overpressure: 1.5 times the pressure range.
  • Accuracy: 0.1% FS.
  • Temperature Range: 0-50°C.
  • Stability: Typical 0.1% FS, max 0.2% FS.
  • Supply Voltage: 8-28 VDC.
  • Switch Outputs: 2 PhotoMOS-Relays, 28 V / 0.4 A.
  • Pressure Connection: G 1/4” or cutting ring, optional connections available.
  • Electrical Connection: Binder (8 pole) or PG-7 cable input.
  • Interface: RS 485.
  • Protection: IP 64.
  • Dimensions: 68 x 70 x 35 mm.
  • Weight: Approximately 100 g (136 g with rubber protection).
Optional Accessories: Protective rubber covering and customizable front display.
See more

Catalog excerpts

dV-2 PS-1

Digital Manometer with Switch Outputs user selected switching points and functions The dV-2 PS is a sophisticated digital pressure gauge with two independent pressure switch outputs. The gauge employs Keller’s proven microprocessor technology which produces highly accurate results. All readings are linearised and temperature corrected, to give an accuracy of 0,2 %FS. There are two independent switches for High and Low control functions. These are solid state and therefore not subject to wear. The switch points are programmed directly from the two front panel buttons and a menu system. Alternatively, the dV-2 PS can be connected via the RS485 link to a laptop/PC, and configured using Keller’s “Pressure Switch Console” software. User defined configurations can be stored on the computer for future reference. Pressure sequences can also be monitored and recorded on the PC for application diagnostic purposes using Keller’s Read30 software. Two independent floating switches are available; neither is subject to wear and they can be operated individually as make or break contacts. The switch can provide a window function or be utilised as a hysteresis switch. These switching functions enable the dV-2 PS to assume control tasks. Respective switch output status is displayed on an LED located on the front. dV-2 PS has the following functions: High/Low The maximum and minimum values are indicated via the Select button. Allows the max. and min. value to be reset at the actual pressure value. Sets the zero to any value as a new zero reference. Barometric pressure variations can thus be compensated. The factory setting of the zero for the ranges ≤ 61 bar is at 0 bar absolute. For sealed gauge pressure measurements, activate “ZERO SEt” at ambient pressure. Instruments with ranges > 61 bar are calibrated in a sealed gauge mode with ambient pressure as a zero reference. Configuration of the switch outputs. Switch points, switch window, switch hysteresis, open and close. SPECIFICATIONS Pressure Ranges absolute Pressure Ranges relative Display Resolution Overpressure Accuracy * Temperature Range Stability Digital Indicators LCD Measuring Interval / Switch Delay Supply Switch Outputs Pressure Connection Electrical Connection Interface Protection Width x Height x Depth Weight 8 x per second ≈ 40 ms 8…28 VDC 2 pcs. PhotoMOS-Relais 28 V / 0,4 A G 1/4” or Cutting ring/clamping ring, ø 6 mm (only up to 600 bar). Optional: other connections. Binder (8 pole) or PG-7 cable input with spring clip in the instrument RS 485 IP 64 68 x 70 x 35 mm ≈ 100 g (with rubber protection ≈136 g) Optional Accessories Protective rubber covering, front display with customer logo * Includes linearity, repeatability, hysteresis and temperature error. Does not include Zero sta