SpeedSys 200/300
7Pages

{{requestButtons}}

Catalog excerpts

SpeedSys 200/300 - 1

SpeedSys® 200 & 300 Overspeed detection system (ODS) GAME CHANGING INNOVATION FOR SIL RATED OVERSPEED PROTECTION SpeedSys ODS is a high-integrity overspeed detection system for rotating machinery. It delivers the core layer of protection with a compact architecture. Its small technical footprint and low-impact installation enables advanced protection to a wide range of applications. The simple and robust design meets the latest safety standards, and features easy maintenance and long proof test intervals. ADVANCED DETECTION FOR A WIDE RANGE OF APPLICATIONS ▪ ▪ ▪ Overspeed, underspeed and acceleration detection Typical applications include: for critical and semi-critical rotating machinery Designed for versatility and scalable to any Wind turbines Marine applications SAFETY SYSTEM BY DESIGN ▪ Suitable for all common sensor types Fast 8 ms hardware response time (relays) External voting for redundant configurations 2 safety relays + 1 safety analog output per module Advanced self-monitoring and diagnostics Discrete in- and output (SpeedSys 300 only) 10 years proof test interval (typical) Modbus RS485 (SpeedSys 300 only) DATASHEET SPEEDSYS ODS (OVERSPEED DETECTION SYSTEM)

Open the catalog to page 1
SpeedSys 200/300 - 2

DATASHEET SPEEDSYS OVERSPEED DETECTION SYSTEM (ODS) VERSATILE ARCHITECTURE Each channel is designed to work as an independent module. SIL 2 rated protection can be achieved with a single module. SIL 3 rated protection can only be achieved with the SpeedSys 300 and with a HFT ≥ 1. To maximize safety or availability, the double pole safety relays can easily be wired into various configurations. Figure 1: configuration examples with SpeedSys 300. Configuration is identical for SpeedSys 200. Relays are depicted energized-closed. INPUT Input channels Sensor input 3 separate sensor inputs for...

Open the catalog to page 2
SpeedSys 200/300 - 3

DATASHEET SPEEDSYS OVERSPEED DETECTION SYSTEM (ODS) Electromagnetic sensors, depending on electromagnetic environment, sensor and application design, can have a maximum cable length ranging from 30 to 500 m. (3) Proximity sensor Input type 2-wire current input Note: 2-wire dynamic current eddy current probe ONLY Sensor power supply Input range Trigger level (programmable) Sensor monitoring Open circuit detection, short circuit detection Proximity sensors are typically suitable for cable lengths up to 1000 m. Binary input / Proof test trigger (SpeedSys 300 only) Number Input type Open...

Open the catalog to page 3
SpeedSys 200/300 - 4

DATASHEET SPEEDSYS OVERSPEED DETECTION SYSTEM (ODS) 30 VDC / 100 mA (inductive load) Hysteresis Safe state User-configurable normally open or normally closed No. The additional relays are NOT part of the SIL approvals and cannot be used for critical machine protection applications. Binary output (SpeedSys 300 only) Number Open collector output (requires external pull-up resistor of ± 2.4 kΩ) Fast signalling output to announce system status ahead of relays. User-configurable identical to the relays. Maximum capacity No. The discrete output is NOT part of the SIL approvals and cannot be used...

Open the catalog to page 4
SpeedSys 200/300 - 5

DATASHEET SPEEDSYS OVERSPEED DETECTION SYSTEM (ODS) SYSTEM Reaction time Measurement time (Tm) Dependent on signal frequency and averaging, typically ± 2 ms Hardware reaction time (Th) Relays, typical: Total reaction time (Th + Tm) PC interface USB-B mini for programming and status reading (Windows® 7 and higher proprietary software application) Power supply input Number 2 redundant power supply inputs Input voltage range Current consumption Reverse polarity protection Heat dissipation Yes SpeedSys 200: maximum 5.0 W (@ 24 VDC) SpeedSys 300: maximum 5.3 W (@ 24 VDC) Housing Material...

Open the catalog to page 5
SpeedSys 200/300 - 6

DATASHEET SPEEDSYS OVERSPEED DETECTION SYSTEM (ODS) APPROVALS Conformities FCC 47 CFR, part 15 (according to ANSI C 63.4) EN 61326:2017 EN 55011:2016/A1:2017 Electrical equipment (safety) / LVD Environmental / RoHS Hazardous areas / ATEX EN IEC 60079-0:2018 (See section: Hazardous Areas) Functional safety HAZARDOUS AREAS Type of protection Approval marking Identifiers Ex ia; intrinsic safety on sensor inputs II (1)G [Ex ia Ga] IIC Important information Certification refers to sensor input only. Refer to the certificates for specific parameters of the mode of operation and special conditions...

Open the catalog to page 6
SpeedSys 200/300 - 7

DATASHEET SPEEDSYS OVERSPEED DETECTION SYSTEM (ODS) Figure 2: connection diagram SpeedSys ODS. Relays are depicted de-energized-open. ABOUT ISTEC We ensure maximal value generation of your critical machinery with advanced protection and monitoring solutions. Every Istec product is designed to meet the increasing demands of industrial applications and taps into our 50 years of experience in the industry. Our expertise is to support and maintain these critical sensors and systems in the field throughout their operational life; to increase safety, maximize machine availability and to provide...

Open the catalog to page 7

All Istec catalogs and technical brochures

  1. T11

    6 Pages

  2. SpeedSys 200

    6 Pages

  3. ISTACCSI10

    1 Pages

  4. ISTACCSS20

    1 Pages

  5. ISTACCSS10

    1 Pages

  6. ISTACCTS10