Product catalog summary
Overview: The document provides technical specifications and operational details for the NIMOS S6 Modular PSA Nitrogen Generators, focusing on nitrogen purity, flow rates, and equipment requirements.
Nitrogen Purity and Flow Rates: The generator offers varying nitrogen purity levels from 95% to 99.999%, with corresponding residual oxygen levels ranging from 5% to 10 PPM. Flow rates are specified at two different inlet pressures (7.5 bar and 9.5 bar), with higher pressures yielding greater flow rates.
Feed Air Requirements: The air quality must meet ISO 8573.1 Class 1-4-1 standards, with specific limits on solid particles, dew point, and oil content. The required pressure range is 6-10 bar, and the temperature range is 0 to +45°C.
Nitrogen Specifications: The outlet pressure ranges from 0-9 bar, with a dew point of less than 40°C. The nitrogen process tank has a capacity of 500 liters. Power supply requirements are 230 V / 50-60 Hz with a maximum consumption of 0.5 kW.
Dimensions and Weight: The generator's dimensions are 440 mm (M) x 900 mm (L) x 1550 mm (P) x 2070 mm (H), and it weighs 600 kg. Connection points include G1" for air inlet and nitrogen outlets, and G3" for O2 enriched air outlet.
Standard Equipment and Options: The generator includes a control panel with a 4-line display, purity monitoring with various O2 sensors, and a dew point sensor. Optional equipment includes additional sensors, exhaust silencers, and data logging capabilities. Necessary accessories include a process tank with all required components.
See more

Catalog excerpts

NIMOS S6-1

M OD ULAR P S A NITROGEN GENER AT O R S Performance at inlet pressure: bar (g) 7,5 LP Nitrogen purity rate Residual oxygen Flow nm³/h (1) Flow rates at standard atmospheric conditions (20°C/1000 mbar/0% RH) Performance at inlet pressure: Nitrogen purity rate Residual oxygen Flow nm³/h (1) Flow rates at standard atmospheric conditions (20°C/1000 mbar/0% RH) Dew point at atmospheric pressure. Outlet pressure: Necessary for guarantee performance of the nitrogen generator (integrated). Nitrogen Specifications Nitrogen process tank: (3) Power Consumption: Power Supply:

 Open the catalog to page 1
NIMOS S6-2

MODULAR PSA NITROGEN GENERATORS Dimensions & Weight Logging and data handling Analog output 4-20mA (O, level)_• Modbus RS485/USB serial converter o Profibus connection convert o Canbus connection convert o Ewon (webserver + sms alarm + data logging) o Digital remote control • Extern alarm digital input • STANDARD EQUIPMENT AND OPTIONS Control panel_ Purity monitoring and control O2 Electrochemical Sensor 0-25 % o • = standard equipment O, Zirconium Sensor 0-25 %_o o = option O, Zirconium Sensor 10-1000 ppm_o Dew point sensor with indication on display o Flow meter...

 Open the catalog to page 2

All Isolcell catalogs and technical brochures

  1. NIMOS S7

    2  Pages

  2. NIMOS M4

    2  Pages

  3. NIMOS NM4

    2  Pages

  4. NIMOS NM3

    2  Pages

  5. NIMOS NM2

    2  Pages

  6. NIMOS NM1

    2  Pages

  7. NIMOS D10

    2  Pages

  8. NIMOS D9

    2  Pages

  9. NIMOS D8

    2  Pages

  10. NIMOS S10

    2  Pages

  11. NIMOS S9

    2  Pages

  12. NIMOS S8

    2  Pages

  13. NIMOS M3

    2  Pages

  14. NIMOS M2

    2  Pages

  15. NIMOS M1

    2  Pages

  16. NIMOS D7

    2  Pages

  17. NIMOS D6

    2  Pages

  18. Brochure

    20  Pages

  19. NIMOS S5

    2  Pages

  20. NIMOS S4

    2  Pages

  21. NIMOS S3

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.