video corpo

NIMOS S2

NIMOS S2

NIMOS S2

Product catalog summary
Overview: The document provides technical specifications and operational details for the Modular PSA Nitrogen Generators, specifically the NIMOS S2 model. It includes information on nitrogen purity rates, flow rates, feed air requirements, dimensions, weight, and standard equipment options.
Nitrogen Purity and Flow Rates: The nitrogen generators offer varying purity levels from 95% to 99.999%, with corresponding residual oxygen levels ranging from 5% to 10 PPM. Flow rates are provided for two inlet pressures: 7.5 bar(g) and 9.5 bar(g), with flow rates decreasing as purity increases.
Feed Air Requirements: The required air quality is specified as Class 1-4-1 according to ISO 8573.1, with solid particles less than 0.1 µm, a dew point below +3°C, and oil content less than 0.01 mg/m³. The pressure range is 6-10 bar(g), and the temperature range is 0 to +45°C.
Nitrogen Specifications: The outlet pressure ranges from 0-9 bar(g), with a dew point of less than 40°C. The nitrogen process tank has a capacity of 270 liters. Power supply requirements are 230 V / 50-60 Hz with a maximum power consumption of 0.5 kW.
Dimensions and Weight: The generator's dimensions are 440 mm (M) x 900 mm (L) x 1150 mm (P) x 2070 mm (H), and it weighs 350 kg. Connection points include G1" for air inlet, N2 outlet, and process tank connections, and G3" for O2 enriched air outlet.
Standard Equipment and Options: The generator includes a control panel with a 4-line display, purity monitoring with various O2 sensors, a dew point sensor, and a flow meter. Additional options include various sensors, valves, logging and data handling capabilities, and digital remote control features. A process tank with accessories is necessary.
See more

Catalog excerpts

NIMOS S2-1

M OD ULAR P S A NITROGEN GENER AT O R S Performance at inlet pressure: bar (g) 7,5 LP Nitrogen purity rate Residual oxygen Flow nm³/h (1) Flow rates at standard atmospheric conditions (20°C/1000 mbar/0% RH) Performance at inlet pressure: Nitrogen purity rate Residual oxygen Flow nm³/h (1) Flow rates at standard atmospheric conditions (20°C/1000 mbar/0% RH) Dew point at atmospheric pressure. Outlet pressure: Necessary for guarantee performance of the nitrogen generator (integrated). Nitrogen Specifications Nitrogen process tank: (3) Power Consumption: Power Supply:

 Open the catalog to page 1
NIMOS S2-2

MODULAR PSA NITROGEN GENERATORS Logging and data handling Analog output 4-20mA (O, level)_• Modbus RS485/USB serial converter o Profibus connection convert o Canbus connection convert o Ewon (webserver + sms alarm + data logging) o Digital remote control • Extern alarm digital input • STANDARD EQUIPMENT AND OPTIONS Control panel_ Purity monitoring and control O2 Electrochemical Sensor 0-25 % o • = standard equipment O, Zirconium Sensor 0-25 %_o o = option O, Zirconium Sensor 10-1000 ppm_o Dew point sensor with indication on display o Flow meter with indication on...

 Open the catalog to page 2

All Isolcell catalogs and technical brochures

  1. NIMOS S7

    2  Pages

  2. NIMOS M4

    2  Pages

  3. NIMOS NM4

    2  Pages

  4. NIMOS NM3

    2  Pages

  5. NIMOS NM2

    2  Pages

  6. NIMOS NM1

    2  Pages

  7. NIMOS D10

    2  Pages

  8. NIMOS D9

    2  Pages

  9. NIMOS D8

    2  Pages

  10. NIMOS S10

    2  Pages

  11. NIMOS S9

    2  Pages

  12. NIMOS S8

    2  Pages

  13. NIMOS M3

    2  Pages

  14. NIMOS M2

    2  Pages

  15. NIMOS M1

    2  Pages

  16. NIMOS D7

    2  Pages

  17. NIMOS D6

    2  Pages

  18. Brochure

    20  Pages

  19. NIMOS S6

    2  Pages

  20. NIMOS S5

    2  Pages

  21. NIMOS S4

    2  Pages

  22. NIMOS S3

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.