M OD ULAR P S A NITROGEN GENER AT O R S Performance at inlet pressure: bar (g) 7,5 LP Nitrogen purity rate Residual oxygen Flow nm³/h (1) Flow rates at standard atmospheric conditions (20°C/1000 mbar/0% RH) Performance at inlet pressure: Nitrogen purity rate Residual oxygen Flow nm³/h (1) Flow rates at standard atmospheric conditions (20°C/1000 mbar/0% RH) Nitrogen Specifications Class 1-4-1 ISO 8573.1 Outlet pressure: Oil < 0,01 mg/m³ Dew point at atmospheric pressure. Necessary for guarantee performance of the nitrogen generator. Compressor Fad Flow rate: Power Requirements Power Supply: Power Consumption:
Open the catalog to page 1MODULAR PSA NITROGEN GENERATORS STANDARD EQUIPMENT AND OPTIONS Control panel_ 5” Touch Screen display • Purity monitoring and control O, Electrochemical Sensor 0-25 % o • = standard equipment O, Zirconium Sensor 0-25 %_o o = option O, Zirconium Sensor 10-1000 ppm_o Dew point sensor with indication on display o Flow meter with indication on display o Valves and accessories Back pressure control valve kit o Compressed air pressure sensor o Nitrogen buffer pressure sensor • Process tank pressure sensor o Exhaust silencer • Super exhaust silencer extern mounted o Logging and data handling Analog...