Overview: The document provides technical specifications and features of the NIMOS D6 Modular PSA Nitrogen Generators, detailing performance metrics, equipment dimensions, and available options.
Nitrogen Specifications: The generator offers varying nitrogen purity levels from 95% to 99.999%, with corresponding residual oxygen levels ranging from 5% to 10 PPM. Flow rates are specified under standard atmospheric conditions (20°C/1000 mbar/0% RH) and vary with inlet pressures of 7.5 bar(g) and 9.5 bar(g).
Feed Air Requirements: The air quality must meet ISO 8573.1 Class 1-4-1 standards, with solid particles < 0.1 µm, dew point < +3°C, and oil content < 0.01 mg/m³. Operating pressure ranges from 6 to 10 bar(g) and temperature from 0 to +45°C.
Power Requirements: The system operates on a 230 V / 50-60 Hz power supply with a maximum consumption of 0.5 kW.
Dimensions & Weight: The generator measures 880 mm (M) x 900 mm (L) x 1550 mm (P) x 2070 mm (H) and weighs 1150 kg. It includes various inlet and outlet connections for air and nitrogen.
Standard Equipment and Options: The generator includes a control panel with a 4-line display, purity monitoring with O2 sensors, dew point sensor, and flow meter. Optional accessories include various sensors, exhaust silencers, and data handling interfaces like Modbus and Profibus.
Necessary Accessories: A process tank with all necessary accessories is required for optimal performance.
See more

Catalog excerpts

NIMOS D6-1

M OD ULAR P S A NITROGEN GENER AT O R S Performance at inlet pressure: bar (g) 7,5 LP Nitrogen purity rate Residual oxygen Flow nm³/h (1) Flow rates at standard atmospheric conditions (20°C/1000 mbar/0% RH) Performance at inlet pressure: Nitrogen purity rate Residual oxygen Flow nm³/h (1) Flow rates at standard atmospheric conditions (20°C/1000 mbar/0% RH) Dew point at atmospheric pressure. Nitrogen Specifications Class 1-4-1 ISO 8573.1 Outlet pressure: Necessary for guarantee performance of the nitrogen generator (integrated). Nitrogen process tank: (3) Power Consumption: Power Supply:

 Open the catalog to page 1
NIMOS D6-2

MODULAR PSA NITROGEN GENERATORS Logging and data handling Analog output 4-20mA (O, level)_• Modbus RS485/USB serial converter o Profibus connection convert o Canbus connection convert o Ewon (webserver + sms alarm + data logging) o Digital remote control • Extern alarm digital input • STANDARD EQUIPMENT AND OPTIONS Control panel_ Purity monitoring and control O2 Electrochemical Sensor 0-25 % o • = standard equipment O, Zirconium Sensor 0-25 %_o o = option O, Zirconium Sensor 10-1000 ppm_o Dew point sensor with indication on display o Flow meter with indication on display o Valves and accessories...

 Open the catalog to page 2

All Isolcell catalogs and technical brochures

  1. NIMOS S7

    2  Pages

  2. NIMOS M4

    2  Pages

  3. NIMOS NM4

    2  Pages

  4. NIMOS NM3

    2  Pages

  5. NIMOS NM2

    2  Pages

  6. NIMOS NM1

    2  Pages

  7. NIMOS D10

    2  Pages

  8. NIMOS D9

    2  Pages

  9. NIMOS D8

    2  Pages

  10. NIMOS S10

    2  Pages

  11. NIMOS S9

    2  Pages

  12. NIMOS S8

    2  Pages

  13. NIMOS M3

    2  Pages

  14. NIMOS M2

    2  Pages

  15. NIMOS M1

    2  Pages

  16. NIMOS D7

    2  Pages

  17. Brochure

    20  Pages

  18. NIMOS S6

    2  Pages

  19. NIMOS S5

    2  Pages

  20. NIMOS S4

    2  Pages

  21. NIMOS S3

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.