ISOMAG MS600 - 1

LIGHT "WEIGHT" SENSOR COMPLETELY IN The manufacturer guarantees only English text. Available on our web site: www.isomaq.eu The solutions that count

Open the catalog to page 1
ISOMAG MS600 - 2

The Manufacturer Guarantee Only English Text Available on our web site: www.isoil.com

Open the catalog to page 2
ISOMAG MS600 - 3

TECHNICAL DATA The Manufacturer Guarantee Only English Text Available on our web site: www.isoil.com

Open the catalog to page 3
ISOMAG MS600 - 4

OVERALL DIMENSIONS CONNECTIONS GAS/NPT DIMENSIONS mm (inches) The Manufacturer Guarantee Only English Text Available on our web site: www.isoil.com

Open the catalog to page 4
ISOMAG MS600 - 5

INSTALLATION RECOMMENDATIONS In vertical installations an ascending flow is preferable. For vertical installations with descending flow direction contact the manufacturer For installations in long pipe lines, please use anti vibration joints LONG PIPING Avoid a partially empty pipe, during operation the pipe must be either completely full of liquid or completely empty Install the sensor away from bends and hydraulic accessoriesds and hydraulic accessories Avoid positioning flange and counter flanges by tigthening the nuts. The Manufacturer Guarantee Only English Text Available on our web...

Open the catalog to page 5
ISOMAG MS600 - 6

SENSOR GROUNDING For the correct operation of the meter the sensor and liquid must be equipotential. ALWAYS connect sensor and converter to the ground. The Manufacturer Guarantee Only English Text Available on our web site: www.isoil.com

Open the catalog to page 6
ISOMAG MS600 - 7

SEPARATE VERSION CONDUCTIVITY (µS/cm) It is recommended to install the connection cables away from, or protect against sources of electromagnetic noise. The minimum conductivity of the liquid medium to ensure correct functionality of the empty pipe detection is 20 µS/cm The Manufacturer Guarantee Only English Text Available on our web site: www.isoil.com

Open the catalog to page 7
ISOMAG MS600 - 8

PRESSURE LOSS CALCULATION (CONES 8° ANGLES) = Fluid density [kg/m3] typical value = pipe diameter (greater than sensor diameter) [m] = Mean flow velocity in sensor diameter [m/s] Calculation examples Inner diameter of sensor is used for d, express in meters. as goodness approximation of water density in common use. Indeed pressure loss equation is dimensionally correct in [Pa]. The equation results in table are show in [mbar]. The Manufacturer Guarantee Only English Text Available on our web site: www.isoil.com

Open the catalog to page 8
ISOMAG MS600 - 9

Nominal Diameter / Lining / Maximum temperature / Measuring range P03 DN3 ( 1/8 "), PP lining, measuring range 0.. 10,3 / 0...259 l/h P06 DN6 ( 1/4 "), PP lining, measuring range 0...41,4/0...1036 l/h P10 DN10 (3/8 "), PP lining, measuring range 0..115,2/0...2880 l/h P15 DN15 (1/2 "), PP lining, measuring range 0.. 259,2/0...6480 l/h P20 DN20 (3/4 "), PP lining, measuring range 0.. 460,8/0...11520 l/h Gasket material ( internal tightness ) 1 2 O-Ring : Epdm O-Ring : FFKM Process connection type A Male threated UNI338 ( FOR THE DIMENSIONS CONSULT THE OVERALL DIMENSIONS DRAWING) Male threated...

Open the catalog to page 9