Specifications
  • Application: Designed for commercial heating and cooling systems, compatible with DN15 to DN50, and MID Approved (MI004).
  • Power Supply: Operates on an internal Lithium Battery (3.6 V) with an 11-year lifespan.
  • Pressure: Atmospheric pressure ranges from 86 to 106.7 KPa; Fluid pressure is less than 1.6 MPa (PN16).
  • Temperature: Ambient temperature ranges from 5 to +55°C; Fluid temperature ranges from 5 to +130°C.
  • Accuracy: Class 2 to EN1434, typically 1% accuracy.
  • Energy Units: Measures in kWh, MWh, GJ, Gcal with a maximum thermal power of 2.63 MW.
Heat Meter Table
  • Flow rates range from 0.6 to 15 m3/h, with corresponding pressure losses and connection types.
Installation Guidelines
  • Avoid wiring signal cables near power cables.
  • Do not alter the length of temperature sensor cables.
  • Offers various mounting options: wall, DIN-rail, and direct mounting on the flow sensor housing.
Mounting and Connections
  • Flow sensors DN15 to DN32 have no specific pipeline length requirements; DN40 to DN50 require specific upstream and downstream lengths.
  • Temperature sensors should be mounted head upwards and perpendicular or at a 45° angle to the pipe axis.
Dimensions
  • Mechanical dimensions vary based on connection type, ranging from G3/4" to DN50.
Sealing
  • Includes verification, manufacturer security, and mounting seals.
Operations
  • Information is displayed via a control button, showing integral parameters or error codes if detected.
  • Error codes and parameters such as energy for heating and cooling, integrated energy, and pulse inputs are displayed.
Error Codes
  • Detailed descriptions of error codes are provided, indicating issues with flow, temperature, or calculator errors.
Ordering Information
  • Includes standard and optional features for ordering.
Certification
  • MID and CE certifications confirm compliance with relevant directives.
Temperature Measurements
  • Outlines the measurement of temperature in both the flow and return pipes, as well as the temperature difference, crucial for accurate energy calculations.
Battery and Time Settings
  • Details on the next replacement date for the battery, real-time calendar and clock settings, and yearly and monthly set days.
Tariff Configurations
  • Describes the configuration of Tariff 1 and Tariff 2, based on temperature differences and time intervals, allowing for the selection of measured parameters or pulse inputs for tariff activation.
Pulse Input/Output Configuration
  • Details the configuration for the first and second pulse inputs/outputs, including settings for energy, liquid quantity, and tariff conditions. Maximum pulse resolution is 0.00001 m3.
Heat-Conveying Liquid and Pressure
  • Identifies water as the heat-conveying liquid, with a pressure value for energy calculations specified as 1.6 MPa.
Identification and Software
  • Includes fields for customer number, software version, serial number, and MBus address.
Battery and Operation Time
  • Information on battery operation time and working hours without power calculation errors is provided.
Error Codes
  • Lists potential error codes related to flow, temperature sensors, and calculator status. Each code is explained, with combinations of errors also described. Errors can affect the calculation of thermal energy and water volume.
Ordering and Certification
  • Instructions for ordering and certification details are mentioned, with a reference to the price list for additional options.
See more

Catalog excerpts

ISOFLUX IFX serie 03-1

THE ULTRASONIC FLOW SOLUTION - HEAT METER Ultrasonic Residential Heat Meter for heating & cooling from DN15 to DN50 MID Approved (MI004) Warranty conditions are available on this website: www.isoil.com only in English version

 Open the catalog to page 1
ISOFLUX IFX serie 03-3

TECHNICAL DATA STANDARD FEATURES Application Commercial (local or district heating systems) Heating and cooling Compact Separate (meters of cable to be ordered until 5 meters) Internal Lithium Battery 3,6 V - LiSOCl2 (11 years lifetime) Ambient: 5… +55°C (Calculator); -30… +55°C (Flow sensor) Fluid 5…+130°C <=2,5m3/h; 10…+130°C >= 3,5 m3/h PT100 (PT1000 option) Platinum reistance – 2 wires Matched pairs (supplied in couple) 0…180°C (3…150K or 2…150K on request) EN60751 / EN1434-2 Power supply Pressure Temperature Temperature Probes Humidity Range Accuracy Energy Units kWh, MWh, GJ, Gcal (Max...

 Open the catalog to page 3
ISOFLUX IFX serie 03-4

OTHERS FEATURES Housing materials Brass body Protection Rate Remote Cable length By 2xLED inside electronic box pushing test button 2x Pulses and/or Mbus; RF 868Hz module Thread until 2”; DN50 flanged Time-on flight measurement method WEEE Marking Yes – MI004-EN1434 part 1-6, Environment Class C; Electromagnetic E2 2004/22/EC Annex 1 (Price list includes only standard version) The manufacturer guarantees only English text available on our web site: www.

 Open the catalog to page 4
ISOFLUX IFX serie 03-5

INSTALLATION It is forbidden to wire signal cables nearby (less than 5 cm) with power cables or cables of other devices. It is forbidden to change length of a cable about temperature probes Factory-installed temperature sensors do not split, shorten or extend the cables. Calculator can be mounted in several different ways: - Wall mounting, without possibility sealing of mounting - Wall mounting, with possibility sealing of mounting - Mounting on standard DIN-rail - Panel mounting - Direct mounting on ultrasonic flow sensor housing, turning every 90o (only when the temperature of the flow does...

 Open the catalog to page 5
ISOFLUX IFX serie 03-6

Panel mounting on standard DIN-rail Adapter plate according to EN1434-2:2007 for wall mounting of calculator (if the aperture in the wall is too large for the calculator) The manufacturer guarantees only English text available on our web site: www.isoil.com

 Open the catalog to page 6
ISOFLUX IFX serie 03-7

MOUNTING OF FLOW SENSORS - For flow sensors DN15…DN32: no requirements for straight pipeline length in upstream and downstream directions. - For flow sensors DN40…DN50: upstream straight pipeline length must be not less 5DN and downstream straight pipeline length must be not less 3DN Avoid the flow sensor installation near after the pumps which can cause cavitations. Flow sensor can be mounted both vertically and horizontally in pipelines. Vertically mounting of the flowmeter is allowed only if flow direction in the pipeline is from down to up. The direction of the sensor installation (is indicated...

 Open the catalog to page 7
ISOFLUX IFX serie 03-8

Mechanical dimensions of calculator of heat meter IFX-03 Threaded connections G3/4“ lenght L=110 mm The manufacturer guarantees only English text available on our web site: www.isoil.com Threaded connections G1“ lenght L=130 mm

 Open the catalog to page 8
ISOFLUX IFX serie 03-9

Threaded connections G1 1/4“, lenght L=260 mm Threaded connections G2“ , lenght L=300 mm Flanged connection DN40, mounting lenght L =300 mm The manufacturer guarantees only English text available on our web site: www.isoil.com

 Open the catalog to page 9
ISOFLUX IFX serie 03-10

Flanged connection DN50 , lenght L= 270 mm Calculator general view: the cover is closed, and the cover is opened (1-verification seal, 2-manufacturer security seal , 3 –mounting seal) The manufacturer guarantees only English text available on our web site: www.isoil.com

 Open the catalog to page 10
ISOFLUX IFX serie 03-11

Mounting for meters with threaded Direct probes connection G3/4, G1 or G1 ¼ in accordance with EN1434-2 (standard 1,5 meter cable lenght) Mounting for other types with longer probes from connection G2“ in accordance with EN1434-2 (standard 2,5 meter cable lenght) The manufacturer guarantees only English text available on our web site: www.isoil.com

 Open the catalog to page 11
ISOFLUX IFX serie 03-12

The information can be displayed using control button Integral parameters values (1.2) or– if at least one error has been detected – error code (1.1) are displayed if the button has not been presed for more than 60 seconds. (INT - integral parameters, BIL – statistical data, INF- informative parameters - long press ( 3 s) - shift to the right - short press( 3 s) – shift down) The manufacturer guarantees only English text available on our web site: www.isoil.com

 Open the catalog to page 12
ISOFLUX IFX serie 03-13

Parameter Error code with data stamp of starting oferror Description All three displays, will be displayed in turns in one second interval Calculator errors Temperature 2 errors Temperature 1 errors Flow errors Are shown only at an error in meter work Description of Error codes is presented in p. 6.3.3 Are shows only in the heating and cooling energy meters Integrated energy of tariff 1 "Snowflake" indicates that the tariff is linked to the meter of cooling energy INT Integrated energy of tariff 2 "Snowflake" indicates that the tariff is linked to the meter of cooling energy INT Integrated quantity...

 Open the catalog to page 13
ISOFLUX IFX serie 03-14

Quantity of thermal energy on set day with date stamp Changing with date stamp every 1 second INT Quantity of thermal energy for cooling on set day with date stamp Tariff register 1 on set day with date stamp Changing with date stamp every 1 second INT Tariff register 2 on set day with date stamp Changing with date stamp every 1 second INT Volume of liquid on set day with date stamp Changing with date stamp every 1 second INT 1 pulse input pulse value on set day with date stamp Changing with date stamp every 1 second INT 2 pulse input pulse value on set day with date stamp Changing with date...

 Open the catalog to page 14
ISOFLUX IFX serie 03-15

Quantity of thermal energy for cooling on set day of previous month with date stamp Changing with date stamp every 1 second Tariff register 1 on set day of previous month with date stamp Changing with date stamp every 1 second Tariff register 2 on set day of previous month with date stamp Changing with date stamp every 1 second Volume of liquid on set day of previous month with date stamp Changing with date stamp every 1 second BIL 1 pulse input pulse value on set day of previous month with date stamp Changing with date stamp every 1 second pulse input pulse value on set day of previous month...

 Open the catalog to page 15
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.