Overview: The document outlines the technical specifications for the GKu series of small solenoids, designed for return operation and manufactured by ISLIKER MAGNETE AG. These solenoids comply with DIN VDE 0580 standards.
Specifications: The solenoids come in various models with specific dimensions and strokes:
  • GKu-20.03: Ø20 x 50 mm, 3 mm stroke, 1.8 N force
  • GKu-20.05: Ø20 x 50 mm, 5 mm stroke, 1.2 N force
  • GKu-26.04: Ø26 x 68 mm, 4 mm stroke, 3.7 N force
  • GKu-26.07: Ø26 x 68 mm, 7 mm stroke, 2.2 N force
  • GKu-32.06: Ø32 x 83 mm, 6 mm stroke, 5.8 N force
  • GKu-32.09: Ø32 x 83 mm, 9 mm stroke, 4.4 N force
Performance Parameters: These solenoids operate at a preferred rated voltage of 24VDC, with a maximum of 50VDC, and have a class B insulation rating (130°C). The duty cycle is assessed over a 30-second period, with different percentages indicating operational loads. They are designed to function at 20°C ambient temperature with 90% of their rated voltage.
Design and Compliance: Available in two designs (I and II), the solenoids feature nitrocarburized housing for surface treatment. They are RoHS compliant and free of halogens (PVC), tested for IP20 protection according to IEC 60529 standards.
Ordering Information: The document provides a format for ordering, including solenoid type, diameter, stroke, duty cycle, lead wire type, rated voltage, and design type.
Additional Notes: Force values are approximate and may vary by ±10% due to natural dispersion. Special designs are available upon request, and specifications are subject to change without notice. The document also refers to "Technical Explanations" for further details on solenoid use, installation, and safety instructions.
See more

Catalog excerpts

GKu - Small Solenoid (return operation)-1

ISLIKER MAGNETE AG www.islikermagnete.ch GKu - Kleinmagnet (Umkehrhub) Datenblätter GKu - Small solenoid (return operation) 1/2 ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 | [email protected]

 Open the catalog to page 1
GKu - Small Solenoid (return operation)-2

GKu Small solenoid (return operation) ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 | [email protected] CHE-108.813.409 MWST

 Open the catalog to page 2
GKu - Small Solenoid (return operation)-3

GKu-20.03 Kleinmagnet (Umkehrhub) GKu-20.03 Small solenoid (return operation) Magnet bestromt gezeichnet (Stossseite) Magnet bestromt gezeichnet (Stossseite) Solenoid illustrated in energised position (push side) Solenoid illustrated in energised position (push side) Die Spieldauer fur die Berechnung der Einschaltdauer be-tragt 30 sec. = Nicht Standard / not standard ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 I [email protected]

 Open the catalog to page 3
GKu - Small Solenoid (return operation)-4

GKu-20.03 Kleinmagnet (Umkehrhub) GKu-20.03 Small solenoid (return operation)Spezifikationen Specifications Funktion Type GK: D.C. small solenoid u: return operation Diameter of solenoid [mm] Rated stroke of solenoid [mm] Duty cycle push [%] Duty cycle pull [%] W: Lead wire Rated voltage [V] Durchmesser des Magneten [mm] Nennhub des Magneten [mm] Einschaltdauer Stoss (ED) [%] Einschaltdauer Zug (ED) [%] Bemerkungen 1) Magnete hergestellt und gepruft nach DIN VDE 0580 2) Magnetkraft betriebswarm gemessen bei 20°C Umgebungstemperatur, waagrechter Bewegungsrichtung mit 90% Nennspannung 3) Die Magnethaftkraftwerte...

 Open the catalog to page 4
GKu - Small Solenoid (return operation)-5

Magnet bestromt gezeichnet (Stossseite) Solenoid illustrated in energised position (push side) Magnet bestromt gezeichnet (Stossseite) Solenoid illustrated in energised position (push side) Die Spieldauer fur die Berechnung der Einschaltdauer be-tragt 30 sec. = Nicht Standard / not standard 1/2 ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 I [email protected]

 Open the catalog to page 5
GKu - Small Solenoid (return operation)-6

GKu-20.05 Kleinmagnet (Umkehrhub) GKu-20.05 Small solenoid (return operation)Spezifikationen Specifications Funktion Type GK: D.C. small solenoid u: return operation Diameter of solenoid [mm] Rated stroke of solenoid [mm] Duty cycle push [%] Duty cycle pull [%] W: Lead wire Rated voltage [V] Durchmesser des Magneten [mm] Nennhub des Magneten [mm] Einschaltdauer Stoss (ED) [%] Einschaltdauer Zug (ED) [%] Bemerkungen 1) Magnete hergestellt und gepruft nach DIN VDE 0580 2) Magnetkraft betriebswarm gemessen bei 20°C Umgebungstemperatur, waagrechter Bewegungsrichtung mit 90% Nennspannung 3) Die Magnethaftkraftwerte...

 Open the catalog to page 6
GKu - Small Solenoid (return operation)-7

GKu-26.04 Kleinmagnet (Umkehrhub) GKu-26.04 Small solenoid (return operation) Magnet bestromt gezeichnet (Stossseite) Solenoid illustrated in energised position (push side) Magnet bestromt gezeichnet (Stossseite) Solenoid illustrated in energised position (push side) Die Spieldauer fur die Berechnung der Einschaltdauer be-tragt 30 sec. = Nicht Standard / not standard 1/2 ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 I [email protected] CHE-108.813.409 MWST

 Open the catalog to page 7
GKu - Small Solenoid (return operation)-8

GKu-26.04 Kleinmagnet (Umkehrhub) GKu-26.04 Small solenoid (return operation)Spezifikationen Specifications Funktion Type GK: D.C. small solenoid u: return operation Diameter of solenoid [mm] Rated stroke of solenoid [mm] Duty cycle push [%] Duty cycle pull [%] W: Lead wire Rated voltage [V] Durchmesser des Magneten [mm] Nennhub des Magneten [mm] Einschaltdauer Stoss (ED) [%] Einschaltdauer Zug (ED) [%] Bemerkungen 1) Magnete hergestellt und gepruft nach DIN VDE 0580 2) Magnetkraft betriebswarm gemessen bei 20°C Umgebungstemperatur, waagrechter Bewegungsrichtung mit 90% Nennspannung 3) Die Magnethaftkraftwerte...

 Open the catalog to page 8
GKu - Small Solenoid (return operation)-9

GKu-26.07 Kleinmagnet (Umkehrhub) GKu-26.07 Small solenoid (return operation) Ausfuhrung I / Design I Ausfuhrung II / Design II 49 Magnet bestromt gezeichnet (Stossseite) Solenoid illustrated in energised position (push side) Magnet bestromt gezeichnet (Stossseite) Solenoid illustrated in energised position (push side) Die Spieldauer fur die Berechnung der Einschaltdauer be-tragt 30 sec. = Nicht Standard / not standard 1/2 ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 I [email protected] CHE-108.813.409 MWST

 Open the catalog to page 9
GKu - Small Solenoid (return operation)-10

GKu-26.07 Kleinmagnet (Umkehrhub) GKu-26.07 Small solenoid (return operation)Spezifikationen Specifications Funktion Type GK: D.C. small solenoid u: return operation Diameter of solenoid [mm] Rated stroke of solenoid [mm] Duty cycle push [%] Duty cycle pull [%] W: Lead wire Rated voltage [V] Durchmesser des Magneten [mm] Nennhub des Magneten [mm] Einschaltdauer Stoss (ED) [%] Einschaltdauer Zug (ED) [%] Bemerkungen 1) Magnete hergestellt und gepruft nach DIN VDE 0580 2) Magnetkraft betriebswarm gemessen bei 20°C Umgebungstemperatur, waagrechter Bewegungsrichtung mit 90% Nennspannung 3) Die Magnethaftkraftwerte...

 Open the catalog to page 10
GKu - Small Solenoid (return operation)-11

GKu-32.06 Kleinmagnet (Umkehrhub) GKu-32.06 Small solenoid (return operation) Magnet bestromt gezeichnet Magnet bestromt gezeichnet Solenoid illustrated in energised position Solenoid illustrated in energised position Die Spieldauer fur die Berechnung der Einschaltdauer be-tragt 30 sec. = Nicht Standard / not standard 1/2 ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 I [email protected]

 Open the catalog to page 11
GKu - Small Solenoid (return operation)-12

GKu-32.06 Kleinmagnet (Umkehrhub) GKu-32.06 Small solenoid (return operation)Spezifikationen Specifications Funktion Type GK: D.C. small solenoid u: return operation Diameter of solenoid [mm] Rated stroke of solenoid [mm] Duty cycle push [%] Duty cycle pull [%] W: Lead wire Rated voltage [V] Durchmesser des Magneten [mm] Nennhub des Magneten [mm] Einschaltdauer Stoss (ED) [%] Einschaltdauer Zug (ED) [%] Bemerkungen 1) Magnete hergestellt und gepruft nach DIN VDE 0580 2) Magnetkraft betriebswarm gemessen bei 20°C Umgebungstemperatur, waagrechter Bewegungsrichtung mit 90% Nennspannung 3) Die Magnethaftkraftwerte...

 Open the catalog to page 12
GKu - Small Solenoid (return operation)-13

Ausfuhrung I / Design I Ausfuhrung II / Design II 5.5, Magnet bestromt gezeichnet Solenoid illustrated in energised position Magnet bestromt gezeichnet Solenoid illustrated in energised position Die Spieldauer fur die Berechnung der Einschaltdauer be-tragt 30 sec. = Nicht Standard / not standard 1/2 ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 | [email protected] CHE-108.813.409 MWST

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.