1. Catalogs
  2. ISLIKER MAGNETE AG
  3. GIu - Industrial Solenoid (return operation)

GIu - Industrial Solenoid (return operation)
1 /30Pages

GIu - Industrial Solenoid (return operation)

GIu - Industrial Solenoid (return operation)
1 /30Pages

Catalog excerpts

GIu - Industrial Solenoid (return operation)-1

ISLIKER MAGNETE AG www.islikermagnete.ch GIu - Industriemagnet (Umkehrhub) Datenblätter GIu - Industrial solenoid (return operation) 1/2 ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 | [email protected]

 Open the catalog to page 1
GIu - Industrial Solenoid (return operation)-2

GIu Industrial solenoid (return operation) ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 | [email protected] CHE-108.813.409 MWST

 Open the catalog to page 2
GIu - Industrial Solenoid (return operation)-3

GIu-40.08 Industriemagnet (Umkehrhub) GIu-40.08 Industrial solenoid (return operation) Magnet bestromt gezeichnet (Stossseite) Solenoid illustrated in energised position (push side) Optionen: Flansch (I) / Schutzart IP65 Options: flange (I) / degree of protection IP65 Hub/stroke = 8mm s z 1/4 ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 | [email protected]

 Open the catalog to page 3
GIu - Industrial Solenoid (return operation)-4

GIu-40.08 Industriemagnet (Umkehrhub) GIu-40.08 Industrial solenoid (return operation) Elektrischer Anschluss: Steckanschluss (S) / Electrical termination: Plug-in connection (S) ohne Gleichrichter / without rectifier (max. 16A) q 26 2/4 ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 | [email protected]

 Open the catalog to page 4
GIu - Industrial Solenoid (return operation)-5

GIu-40.08 Industriemagnet (Umkehrhub) GIu-40.08 Industrial solenoid (return operation)Elektrischer Anschluss: Litzenanschluss (W) / Electrical termination: Lead wires (W) 2022-12 1.2 Die Spieldauer fur die Berechnung der Einschaltdauer be-tragt 300 sec. = Nicht Standard / not standard

 Open the catalog to page 5
GIu - Industrial Solenoid (return operation)-6

Ordering specification Durchmesser des Magneten [mm] Nennhub des Magneten [mm] Einschaltdauer Stoss (ED) [%] Einschaltdauer Zug (ED) [%] W: Litzenanschluss S: Steckanschluss Spannung [V] I mit Flansch III ohne Flansch Ohne erhohte Schutzart kein Index Type GI: D.C. Industrial Solenoid u: return stroke Diameter of solenoid [mm] Rated stroke of solenoid [mm] Duty cycle push [%] Duty cycle pull [%] W: Lead wire S: Plug-in connection Voltage [V] I with flange III without flange Higher degree of protection (only S) without higher degree of protection - no index 1) Magnete hergestellt und gepruft nach...

 Open the catalog to page 6
GIu - Industrial Solenoid (return operation)-7

Magnet bestromt gezeichnet (Stossseite) Solenoid illustrated in energised position (push side) Optionen: Flansch (I) / Schutzart IP65 Options: flange (I) / degree of protection IP65 ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 I [email protected]

 Open the catalog to page 7
GIu - Industrial Solenoid (return operation)-8

GIu-50.10 Industriemagnet (Umkehrhub) GIu-50.10 Industrial solenoid (return operation) Elektrischer Anschluss: Steckanschluss (S) / Electrical termination: Plug-in connection (S) ohne Gleichrichter / without rectifier (max. 16A) ohne Gleichrichter / without rectifier (max. 16A) ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 I [email protected]

 Open the catalog to page 8
GIu - Industrial Solenoid (return operation)-9

GIu-50.10 Industriemagnet (Umkehrhub) GIu-50.10 Industrial solenoid (return operation)Elektrischer Anschluss: Litzenanschluss (W) / Electrical termination: Lead wires (W) 30° Die Spieldauer fur die Berechnung der Einschaltdauer be-tragt 300 sec. = Nicht Standard / not standard

 Open the catalog to page 9
GIu - Industrial Solenoid (return operation)-10

Ordering specification Durchmesser des Magneten [mm] Nennhub des Magneten [mm] Einschaltdauer Stoss (ED) [%] Einschaltdauer Zug (ED) [%] W: Litzenanschluss S: Steckanschluss K: Klemmengehause Spannung [V] Ohne Gleichrichter kein Index Erhohte Schutzart (S oder K) Ohne erhohte Schutzart kein Index Type GI: D.C. Industrial Solenoid u: return stroke Diameter of solenoid [mm] Rated stroke of solenoid [mm] Duty cycle push [%] Duty cycle pull [%] W: Lead wire S: Plug-in connection K: Terminal box Voltage [V] I with flange III without flange With rectifier (only K) without rectifier - no index Higher...

 Open the catalog to page 10
GIu - Industrial Solenoid (return operation)-11

GIu-60.15 Industriemagnet (Umkehrhub) GIu-60.15 Industrial solenoid (return operation) Magnet bestromt gezeichnet (Stossseite) Solenoid illustrated in energised position (push side) Optionen: Flansch (I) / Schutzart IP65 Options: flange (I) / degree of protection IP65 1/4 ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 | [email protected]

 Open the catalog to page 11
GIu - Industrial Solenoid (return operation)-12

GIu-60.15 Industriemagnet (Umkehrhub) GIu-60.15 Industrial solenoid (return operation) Elektrischer Anschluss: Steckanschluss (S) / Electrical termination: Plug-in connection (S) 61 ohne Gleichrichter / without rectifier (max. 16A) q 26 s s = stossen / push z = ziehen (z) / pull (z) Elektrischer Anschluss: Klemmengehäuse (K) / Electrical termination: Terminal box (K) 40 ohne Gleichrichter / without rectifier (max. 16A) s = stossen / push z = ziehen / pull mit Gleichrichter / with rectifier (max. 2A) 1 (~) 2 s = stossen / push z = ziehen / pull ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52...

 Open the catalog to page 12
GIu - Industrial Solenoid (return operation)-13

GIu-60.15 Industriemagnet (Umkehrhub) GIu-60.15 Industrial solenoid (return operation)Elektrischer Anschluss: Litzenanschluss (W) / Electrical termination: Lead wires (W) 30° Die Spieldauer fur die Berechnung der Einschaltdauer be-tragt 300 sec. = Nicht Standard / not standard ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 I [email protected] CHE-108.813.409 MWST

 Open the catalog to page 13
GIu - Industrial Solenoid (return operation)-14

Ordering specification Durchmesser des Magneten [mm] Nennhub des Magneten [mm] Einschaltdauer Stoss (ED) [%] Einschaltdauer Zug (ED) [%] W: Litzenanschluss S: Steckanschluss K: Klemmengehause Spannung [V] Ohne Gleichrichter kein Index Erhohte Schutzart (S oder K) Ohne erhohte Schutzart kein Index Type GI: D.C. Industrial Solenoid u: return stroke Diameter of solenoid [mm] Rated stroke of solenoid [mm] Duty cycle push [%] Duty cycle pull [%] W: Lead wire S: Plug-in connection K: Terminal box Voltage [V] I with flange III without flange With rectifier (only K) without rectifier - no index Higher...

 Open the catalog to page 14
GIu - Industrial Solenoid (return operation)-15

GIu-70.20 Industriemagnet (Umkehrhub) GIu-70.20 Industrial solenoid (return operation) Magnet bestromt gezeichnet (Stossseite) Solenoid illustrated in energised position (push side) Optionen: Flansch (I) / Schutzart IP65 Options: flange (I) / degree of protection IP65 Hub/stroke = 20mm s z 1/4 ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 | [email protected]

 Open the catalog to page 15
GIu - Industrial Solenoid (return operation)-16

GIu-70.20 Industriemagnet (Umkehrhub) GIu-70.20 Industrial solenoid (return operation) Elektrischer Anschluss: Steckanschluss (S) / Electrical termination: Plug-in connection (S) ohne Gleichrichter / without rectifier (max. 16A) Elektrischer Anschluss: Klemmengehause (K) / Electrical termination: Terminal box (K) ohne Gleichrichter / without rectifier (max. 16A) mit Gleichrichter / with rectifier (max. 2A) ISLIKER MAGNETE AG | CH-8450 Andelfingen | +41 52 305 25 25 I [email protected]

 Open the catalog to page 16
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.