Catalog excerpts
TEHNICAL DATA TECHNICAL DATA AF PART UNIVERSAL AF INTERFACE USEFUL BANDWIDTH TRANSIT FILTERS PROGRAMMABLE BAND PASS FIR FILTERS CONNECTION TYPE INPUT / OUTPUT LEVEL ADJUSTMENT CARRIER RACK OPTIONS ET9 INPUT / OUTPUT IMPEDANCE 4-w, SYMMETRICAL, GALVANIC ISOLATED CARRIER RACK FOR ET9 PLC EQUIPMENT UP TO 6 CHANNELS, OUTPUT POWER (PEP) UP TO 60 W CARRIER RACK FOR ET9 PLC EQUIPMENT UP TO 6 CHANNELS, OUTPUT POWER (PEP) UP TO 120 W UNIVERSAL TELEPHONE INTERFACE FXS 2-w SUBSCRIBER INTERFACE - RING FREQUENCY NUMBER OF REQ.-UNITS - INPUT / OUTPUT LEVEL ADJUSTMENT BUILDING BLOCKS FOR ET9 - POWER PART POWER PART POWER SUPPLY UNIT - INPUT / OUTPUT LEVEL ADJUSTMENT SUB RACK FOR POWER AMPLIFIER AND TRANSMIT LINE FILTERS - RING DETECTOR POWER AMPLIFIER 4-w PAX INTERFACE WITH E&M SIGNALING TRANSMIT LINE FILTER RECIVE LINE FILTER - INPUT / OUTPUT LEVEL ADJUSTMENT LINE MATCHING UNIT SUMMING TRANSFORMER UNIT SPEECH LOW-PASS FILTER CUT-OFF FREQUENCY DATA TRANSMISSION BUILDING BLOCKS FOR ET9 - PROCESSING PART MODEM FSK NUMBER OF REQ.-UNITS PROCESSING PART POWER SUPPLY CENTRALIZED MANAGEMENT AND SUPERVISION UNIT MODULATION UNIT AF ACCESS UNIT WITH UNIVERSAL TELEPHONE INTERFACE - TWO 4-w UNIVERSAL AF INTERFACES - ONE 2-w OR 4-w TELEPHONE INTERFACE AF ACCESS UNIT WITH INTEGRATED MODEMS - TRANSMISSION MODE - TRANSMISSION SPEED PEGASUS - GUI BASED PC SOFTWARE FOR SUPERVISION AND CONFIGURATION OVER RS232 OR LAN INTERFACE SNMP TRAPS FOR ET9 EQUIPMENT REMOTE CONTROL LED INDICATORS ON ET9 FRONT PANEL RELAY ALARM OUTPUTS FULL ACCESS TO REMOTE ET9 EQUIPMENT OVER EMBEDDED OPERATIONAL CHANNEL (EOC) STANDARDS STATE RELAY UNIT TELEPROTECTION APPLICATION - TLI/LFI LINE UNIT WITH ANALOGUE LINE INTERFACE - CSR COMMAND AND SIGNALING RELAY UNIT (2 COMMANDS) POWER LINE CARRIER EQUIPMENT ET9 - STORAGE (TEMPERATURE/HUMIDITY) - OPERATION (TEMPERATURE/HUMIDITY) - TWO 4-w UNIVERSAL AF ACCESS INTERFACE * ET9 REQUIRES AT LEAST ONE AF ACCESS UNIT TYPE NF9, TG9 OR AFA POWER SUPPLY POWER SUPPLY MAX. POWER CONSUMPTION - EQUIPMENT CONFIGURATION ET9-60W GENERAL TECHNICAL DATA PLC COMMUNICATION LINKS ORGANIZED OVER HIGH-VOLTAGE TRANSMISSION LINES REMAINS TRADITIONAL SOLUTION IN POWER UTILITIES MECHANICAL CONSTRUCTION NOMINAL CHANNEL BANDWIDTH NORMAL / INVERSE Tx / Rx FREQUENCY BAND POSITION IN RF BAND ADJACENT / NON-ADJACENT CHANNEL ALLOCATION IN RF RANGE PROGRAMMABLE IN ALL RF RANGE , STEP 1 kHz RECEIVER SENSITIVITY NOMINAL OUTPUT IMPEDANCE AMBIENT CONDITIONS EQUIPMENT CONFIGURATION DIMENSIONS (WxHxD) www.iskra.eu • Published by Iskra, d. d. • Version 3.0, December 2017 PLC LINKS ARE POINT TO POINT COMMUNICATIONS USED FOR SIGNALS TRANSMISSION BETWEEN SUBSTATIONS AS WELL AS A PART OF PRIVATE COMMUNICATION SYSTEM OF POWER UTILITIES NEW TECHNOLOGIES AND SOLUTIONS IN OTHER COMMUNICATION SYSTEMS ARE NOW A DAYS USED ALSO IN PLC SYSTEMS. DIGITAL SIGNAL PROCESSING ENABLES TRANSMISSION OF SPEECH, DATA AND TELEPROTECTION SIGNALS INSIDE THE SAME PLC
Open the catalog to page 1POWER LINE CARRIER EQUIPMENT ET9 POWER LINE CARRIER EQUIPMENT ET9 TRANSMISSION OF VOICE CHANNELS (FXO, FXS, 4W E&M) TRANSMISSION OF UP TO 6 PLC CHANNELS EXTENDED CARRIER FREQUENCY RANGE FROM 20 kHz UP TO 1000 kHz – PROGRAMMABLE WITHOUT EXCHANGING HARDWARE AUTOMATIC RF CHANNEL EQUALIZATION (AEQ) TRANSMISSION OF TELEPROTECTION SIGNALING – INTEGRATED OR EXTERNAL DZ9 TELEPROTECTION EQUIPMENT OR EXTERNAL EQUIPMENT OF OTHER VENDORS UNIVERSAL TELEPHONE INTERFACES (FXO, FXS, 4w E&M) TRANSMISSION OF BINARY STATES TRANSMISSION OF DATA USING FSK (50 – 1200 Bd) TELECOMMUNICATION RESOURCE FOR DIFFERENT...
Open the catalog to page 2POWER LINE CARRIER EQUIPMENT ET9 POWER LINE CARRIER EQUIPMENT ET9 TRANSMISSION OF VOICE CHANNELS (FXO, FXS, 4W E&M) TRANSMISSION OF UP TO 6 PLC CHANNELS EXTENDED CARRIER FREQUENCY RANGE FROM 20 kHz UP TO 1000 kHz – PROGRAMMABLE WITHOUT EXCHANGING HARDWARE AUTOMATIC RF CHANNEL EQUALIZATION (AEQ) TRANSMISSION OF TELEPROTECTION SIGNALING – INTEGRATED OR EXTERNAL DZ9 TELEPROTECTION EQUIPMENT OR EXTERNAL EQUIPMENT OF OTHER VENDORS UNIVERSAL TELEPHONE INTERFACES (FXO, FXS, 4w E&M) TRANSMISSION OF BINARY STATES TRANSMISSION OF DATA USING FSK (50 – 1200 Bd) TELECOMMUNICATION RESOURCE FOR DIFFERENT...
Open the catalog to page 3TEHNICAL DATA TECHNICAL DATA AF PART UNIVERSAL AF INTERFACE USEFUL BANDWIDTH TRANSIT FILTERS PROGRAMMABLE BAND PASS FIR FILTERS CONNECTION TYPE INPUT / OUTPUT LEVEL ADJUSTMENT CARRIER RACK OPTIONS ET9 INPUT / OUTPUT IMPEDANCE 4-w, SYMMETRICAL, GALVANIC ISOLATED CARRIER RACK FOR ET9 PLC EQUIPMENT UP TO 6 CHANNELS, OUTPUT POWER (PEP) UP TO 60 W CARRIER RACK FOR ET9 PLC EQUIPMENT UP TO 6 CHANNELS, OUTPUT POWER (PEP) UP TO 120 W UNIVERSAL TELEPHONE INTERFACE FXS 2-w SUBSCRIBER INTERFACE - RING FREQUENCY NUMBER OF REQ.-UNITS - INPUT / OUTPUT LEVEL ADJUSTMENT BUILDING BLOCKS FOR ET9 - POWER PART...
Open the catalog to page 4TEHNICAL DATA TECHNICAL DATA AF PART UNIVERSAL AF INTERFACE USEFUL BANDWIDTH TRANSIT FILTERS PROGRAMMABLE BAND PASS FIR FILTERS CONNECTION TYPE INPUT / OUTPUT LEVEL ADJUSTMENT CARRIER RACK OPTIONS ET9 INPUT / OUTPUT IMPEDANCE 4-w, SYMMETRICAL, GALVANIC ISOLATED CARRIER RACK FOR ET9 PLC EQUIPMENT UP TO 6 CHANNELS, OUTPUT POWER (PEP) UP TO 60 W CARRIER RACK FOR ET9 PLC EQUIPMENT UP TO 6 CHANNELS, OUTPUT POWER (PEP) UP TO 120 W UNIVERSAL TELEPHONE INTERFACE FXS 2-w SUBSCRIBER INTERFACE - RING FREQUENCY NUMBER OF REQ.-UNITS - INPUT / OUTPUT LEVEL ADJUSTMENT BUILDING BLOCKS FOR ET9 - POWER PART...
Open the catalog to page 5All Iskra d.d. catalogs and technical brochures
-
POWER ELECTRONIC CAPACITORS
51 Pages
-
Strip Wound Cores
20 Pages
-
Professional Batteries
4 Pages
-
General Sales Conditions
4 Pages
-
SparkWave SDR GE
2 Pages
-
SparkWave High Speed PDH
2 Pages
-
SparkWave SDR ADM
2 Pages
-
SparkWave SDR STM
2 Pages
-
SparkWave SDR GE2
2 Pages
-
SparkLight ADM 16
2 Pages
-
SparkLight ADM 1,4
2 Pages
-
SparkLight HSP
2 Pages
-
DZ9 Catalogue
2 Pages
-
eMis
27 Pages
-
Bistable switch
26 Pages
-
Low voltage switchgear
138 Pages
-
ECU
2 Pages
-
NEO 3000
37 Pages
-
FPC 200
4 Pages
-
Radio Interfence
72 Pages
-
potentiometers
4 Pages
-
Switch disconectors
7 Pages
-
NFIF
4 Pages
-
NFIB
4 Pages
-
FI, NFI
2 Pages
-
Bistable Switches
24 Pages
-
DC-link and Snubber Capacitors
42 Pages
-
Power Factor Correction Banks
30 Pages
-
Power Electronics Capacitors
5 Pages
-
Dry Capacitors
4 Pages
-
CAU380 Bay Computer
8 Pages
-
MCE940 SCADA
4 Pages
-
NEO3000 Substation System
8 Pages
-
Energy Sector
52 Pages
-
Product line
20 Pages
-
Energy meters
44 Pages
-
Low voltage pfc
30 Pages
-
DC link capacitors and snubbers
16 Pages
-
Electrical measuring instruments
110 Pages
Archived catalogs
-
POWER ELECTRONIC CAPACITORS
49 Pages
-
Moulded case circuit breakers
24 Pages
-
Overvoltage protection
72 Pages
-
DC link capacitors
2 Pages
-
Capacitors Selection Guide
2 Pages
-
Capacitors for electronics
44 Pages
-
Lighting capacitors
28 Pages
-
Motor capacitors
28 Pages
-
Capacitor banks - short form
4 Pages
-
Capacitor banks
32 Pages
-
Induction heating capacitors
24 Pages
-
High-voltage power capacitors
24 Pages