Energy sector Power Factor Correction Equipment
Open the catalog to page 1PFC Capacitors for Low Voltage type KNK Applications The KNK capacitors are used for power factor correction of inductive consumers (transformers, electric motors, rectifiers in industrial networks for voltages of up to 1000 V. sealing washer Design ISKRA KNK Capacitors are constructed by the MKP sistem of low-loss, metalized polypropylene films with a special metalization, whose purpose is to favour the self–healing process and reduce dielectric losses. On the end of the element is zinc metal sprayed to make continuous good electrical contact with electrode metalization on the electric. Three...
Open the catalog to page 4PFC Capacitors for Low Voltage type KNK Discharge Resistor Capacitors should be discharged to < =10 % of the rated voltage prior to being re-energized. KNK capacitors are equipped with a resistor that discharges the capacitor to 75 V under 3 min. Over-Pressure Disconnector Every capacitor is protected against breaking by the overpressure disconnector, which ensures safe disconnection of the capacitor from the network in the event of overloading and at the end of its operational life. interupted wire
Open the catalog to page 5PFC Capacitors for Low Voltagetype KNK Terms and definitions Rated capacitance of a capacitor Cn Capacitance value for which the capacitor has been designed. Rated output of a capacitor Qn Reactive power derivered from the rated values of capacitance, frequency and voltage. Rated voltage of a capacitor Un Mean of the max. permissible value of sinusoidal AC voltage in continuous operation. Rated frequency of a capacitor fn Frequency for which the capacitor has been designed. Rated current of a capacitor In RMS value of the current at rated voltage and frequency, excluding harmonic distortion,...
Open the catalog to page 6PFC Capacitors for Low Voltage type KNK ELECTRICAL CONNECTION Connections to the capacitor terminals must be made with insulated flexible copper conductors. Conductors must have a proper cross section for expected capacitor currents including overloads. Conductors have to be equipped with end sleeves or cable lugs in case of screw terminals. When coupling the capacitors in parallel do not exceed the maximal current per contact. Do not solder leads to the terminals. Check connections periodically to avoid weak connections and overheating of the connecting points. With our 16 and 25 mm2 terminals...
Open the catalog to page 7PFC Capacitors for Low VoltageKNK5015, KNK5065 TECHNICAL DATA Notes: On request, capacitors with other power and voltage ratings, shapes, and connections are available. - all rights reserved for any possible changes. - In-rush current must be limited to maximal permitted value. — Type designation Rated power Rated voltage Diameter x Height (mm) —
Open the catalog to page 8PFC Capacitors for Low Voltage (single-phase)KNK5015 - Cylindrical Aluminium Housing 230 ... 525 V, 1.67 ... 6.25 kVar fn = 50 Hz
Open the catalog to page 9PFC Capacitors for Low Voltage (three-phase)KNK5065 - Cylindrical Aluminium Housing, Delta Connection 400 ... 525 V, 2.5 ... 7.5 kVar fn = 50 Hz
Open the catalog to page 10Power Capacitors for Low Voltage (three-phase)KNK1053, KNK9053 - Cylindrical Aluminium Housing TECHNICAL DATA
Open the catalog to page 11PFC Capacitors for Low Voltage (three-phase)KNK1053 - Cylindrical Aluminium Housing 400 ... 690 V, 10 ... 40 kVar fn = 50 Hz - Delta connection
Open the catalog to page 12PFC Capacitors for Low Voltage (three-phase)KNK1053 - Cylindrical Aluminium Housing fn = 60 Hz
Open the catalog to page 13PFC Capacitors for Low Voltage (three-phase)KNK9053 - Cylindrical Aluminium Housing 400 ... 690 V, 10 ... 30 kVar fn = 50 Hz - Delta connection C„toF)
Open the catalog to page 14PFC Capacitors for Low Voltage (three-phase)KNK9053 - Cylindrical Aluminium Housing fn = 60 Hz
Open the catalog to page 15PFC Capacitors for Low Voltage (three-phase)KNK3053, KNK4053 - Cylindrical Aluminium Housing TECHNICAL DATA
Open the catalog to page 16PFC Capacitors for Low Voltage (three-phase)KNK3053, KNK4053 - Cylindrical Aluminium Housing 220 ... 800 V, 5 ... 40 kVar fn= 50 Hz - Normal duty
Open the catalog to page 17PFC Capacitors for Low Voltage (three-phase)KNK3053, KNK4053 - Cylindrical Aluminium Housing fn = 50 Hz - Normal duty
Open the catalog to page 18PFC Capacitors for Low Voltage (three-phase)KNK3053, KNK4053 - Cylindrical Aluminium Housing fn = 50 Hz - Heavy duty
Open the catalog to page 19PFC Capacitors for Low Voltage (three-phase)KNK3053, KNK4053 - Cylindrical Aluminium Housing fn = 60 Hz - Normal duty
Open the catalog to page 20PFC Capacitors for Low Voltage (three-phase)KNK3053, KNK4053 - Cylindrical Aluminium Housing fn = 60 Hz - Heavy duty
Open the catalog to page 21PFC Capacitors for Low Voltage (single- and three-phase)KNK9103, KNK9143, KNK9101, KNK9141 - Prismatic TECHNICAL DATA
Open the catalog to page 22PFC Capacitors for Low Voltage (three-phase)KNK9103, KNK9143 - Prismatic fn = 50 Hz
Open the catalog to page 24PFC Capacitors for Low Voltage (three-phase)KNK9103, KNK9143 - Prismatic fn = 60 Hz
Open the catalog to page 25PFC Capacitors for Low Voltage (single-phase)KNK9101, KNK9141 - Prismatic 230 ... 525 V, 5 ... 60 kVar The cap for KNK9101 (type KNK9151)
Open the catalog to page 26PFC Capacitors for Low Voltage (single-phase)KNK9101, KNK9141 - Prismatic fn = 50 Hz
Open the catalog to page 27High Voltage Power Capacitors KLV Three-phase capacitors Single-phase capacitors Single-phase with two outputs - Twin Capacitors General Advanced technology of KLV capacitors is based on construction of all-film capacitor sections, folding foil edge design, improved electrical and mechanical connections between sections and impregnation with environmentally compatible insulating oil. KLV capacitors have very low dielectric losses and are designed for long service life. KLV 3xxx - Internally fused capacitors. Each capacitor element has a separate internal fuse. KLV1xxx - Capacitors without internal...
Open the catalog to page 28Service conditions Temperature categories up to -40 /D Upper temperature category limit C D Highest mean over 24 h 40 45 Highest mean over 1 year 30 35 Low temperature limit during operation -25 °C or -40 °C Installation: Installation altitude (above sea level): Case material: Finish / Colour: Fixing: Outdoor or indoor 1000 m standard, up to 4000 m on demand Stainless steel plate 1.5 mm thick Two-component durable painting RAL 7032 (light grey) on treated surfaces. Depending on the height of capacitor, con-tainer is equiped with one or two mounting brackets on the narower sides....
Open the catalog to page 2951 Pages
20 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
27 Pages
26 Pages
138 Pages
2 Pages
37 Pages
4 Pages
72 Pages
4 Pages
7 Pages
4 Pages
4 Pages
2 Pages
24 Pages
42 Pages
20 Pages
30 Pages
5 Pages
4 Pages
8 Pages
4 Pages
8 Pages
52 Pages
44 Pages
30 Pages
16 Pages
110 Pages
49 Pages
44 Pages
28 Pages
2 Pages
28 Pages
4 Pages
24 Pages
32 Pages
24 Pages
2 Pages
24 Pages
72 Pages