Catalog excerpts
ENERGY SECTOR POWER ELECTRONIC CAPACITORS • DC LINK CAPACITORS & SNUBBER CAPACITORS -RELEVANT FOR WIND PLANTS, SOLAR POWER PLANTS, MEDICAL AND INDUSTRIAL EQUIPMENT, CAR ELECTRONICS • AC/DC GENERAL PURPOSE CAPACITORS -RELEVANT FOR POWER ELECTRONIC APPLICATIONS WITH HIGH CURRENT AND HARMONICS DISTORTION WITH LONG LIFE EXPECTANCY
Open the catalog to page 1ISKRA MANUFACTURES AND SUPPLIES A WIDE RANGE OF POWER ELECTRONIC CAPACITORS WHICH CAN BE USED FOR VARIOUS FUNCTIONS IN ELECTRIC CIRCUITS. THEY ARE MOST COMMONLY USED IN FREQUENCY OR VOLTAGE INVERTERS, UNINTERRUPTIBLE POWER SUPPLIES, MOTOR DRIVES, WELDING EQUIPMENT, WIND AND SOLAR POWER SYSTEMS. A TYPICAL SWITCHING-MODE POWER SUPPLY IS SHOWN IN THE FIGURE BELOW. DC LINK CAPACITORS AT POSITION C1 ARE USED FOR DC VOLTAGE SMOOTHING. CAPACITORS AT POSITION C2 ARE SNUBBER CAPACITORS. WHEN A SWITCH OPENS, THEY ELIMINATE VOLTAGE SPIKES CAUSED BY CIRCUIT INDUCTANCE. AC FILTERING CAPACITORS AT...
Open the catalog to page 2• CN- RATED CAPACITANCE NOMINAL VALUE OF CAPACITANCE MEASURED AT 20 °C. • UNDC - RATED DC VOLTAGE MAXIMUM OPERATING PEAK VOLTAGE OF EITHER POLARITY BUT OF A NON-REVERSING TYPE WAVEFORM FOR WHICH THE CAPACITOR HAS BEEN DESIGNED. • Urms - RATED RMS VOLTAGE ROOT MEAN SQUARE OF MAX. PERMISSIBLE VALUE OF SINUSOIDAL AC VOLTAGE IN CONTINUOUS OPERATION. • UN - RATED AC VOLTAGE MAXIMUM OPERATING PEAK RECURRENT VOLTAGE OF EITHER POLARITY OF A REVERSING TYPE WAVEFORM FOR WHICH THE CAPACITOR HAS BEEN DESIGNED. • Ur- RIPPLE VOLTAGE PEAK-TO-PEAK ALTERNATING COMPONENT OF THE UNIDIRECTIONAL VOLTAGE. • Imax...
Open the catalog to page 3APPLICATIONS • HYBRID VEHICLES • WIND PLANTS • ELECTRIC ENERGY GENERATION FROM SEA WAVES • MEDICAL EQUIPMENT • INDUSTRIAL EQUIPMENT • CAR ELECTRONICS • RAILWAYS AND TURBINES (GENERATOR) • FREQUENCY INVERTERS • ELEVATORS • WELDERS REFERENCE STANDARDS • IEC61071 • UL 810 (CONSTRUCTION ONLY) FILE No.: E196169 CAPACITANCE RANGE CAPACITANCE TOLERANCE VOLTAGE RANGE DISSIPATION FACTOR TAN(A0) SERIES RESISTANCE DIELECTRIC TEMPERATURE COEFFICIENT OPERATING TEMPERATURE INDUCTANCE TEST VOLTAGE CASING MATERIAL CAP FILLING TERMINALS TORQUE OF TERMINALS BASE STUD MAX. ALTITUDE MAX. HOT SPOT TEMPERATURE...
Open the catalog to page 4GENERAL CHARACTERISTICS CAPACITANCE RANGE
Open the catalog to page 5APPLICATIONS • SWITCHING MODE POWER SUPPLIES (SMPS) • WIND PLANTS • SOLAR POWER PLANTS • MOTOR DRIVES • INDUCTION HEATERS • FREQUENCY INVERTERS • UNINTERRUPTIBLE POWER SUPPLIES (UPS) • FOR HARSH ENVIRONMENT • SELF-HEALING PROPERTIES • HIGH RIPPLE CURRENT • HIGH RELIABILITY • VERY LOW LOSSES SPECIFICATIONS • RATED CAPACITANCE • CAPACITANCE TOLERANCE • RATED VOLTAGE UNDC • TEST VOLTAGE • SELF-INDUCTANCE • INSULATION RESISTANCE BETWEEN TERMINALS • OPERATING TEMPERATURE RANGE • CLIMATIC CATEGORY • LIFE EXPECTANCY TERMINAL TO TERMINAL = 1.5xUNDC, 10 s < 1nH PER mm OF PITCH RxC > 30 000 s AFTER 1...
Open the catalog to page 7GENERAL CHARACTERISTICS CAPACITANCE RANGE (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (3) MAXIMUM tan(5) VALUES MEASURED AT 1 kHz. (4) TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz.
Open the catalog to page 8GENERAL CHARACTERISTICS CAPACITANCE RANGE (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (3) MAXIMUM tan(5) VALUES MEASURED AT 1 kHz. (4) TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz.
Open the catalog to page 9GENERAL CHARACTERISTICS CAPACITANCE RANGE (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (3) MAXIMUM tan(5) VALUES MEASURED AT 1 kHz. (4) TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz.
Open the catalog to page 10GENERAL CHARACTERISTICS CAPACITANCE RANGE NOTES: (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (2) NOMINAL DIMENSIONS. (3) MAXIMUM tan(5) VALUES MEASURED AT 1 kHz. (4) TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz. (5) MAXIMUM R.M.S. CURRENT AT 10 kHz, 0,mb = 70°C FOR A9ase< 20°C.
Open the catalog to page 11GENERAL CHARACTERISTICS CAPACITANCE RANGE NOTES: (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (2) NOMINAL DIMENSIONS. (3) MAXIMUM tan(5) VALUES MEASURED AT 1 kHz (4) TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz. (5) MAXIMUM R.M.S. CURRENT AT 10 kHz, 0,mb = 70°C FOR A9ase< 20°C.
Open the catalog to page 12GENERAL CHARACTERISTICS CAPACITANCE RANGE NOTES: (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (2) NOMINAL DIMENSIONS. (3) MAXIMUM tan(5) VALUES MEASRED AT 1kHz. (4) TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz. (5) MAXIMUM R.M.S. CURRENT AT 10 kHz, 0,mb = 70°C FOR A9ase< 20°C.
Open the catalog to page 13DIMENSIONS TERMINAL DIMENSIONS CONSTRUCTION • DIELECTRIC: POLYPROPYLENE FILM • CAPACITOR ELECTRODES: VACUUM-DEPOSITED • CASING: PLASTIC CASE WITH FLAME-RETARDANT EPOXY RESIN SEALING (UL 94 V-0) • TERMINAL: PARALLEL TINNED COPPER (2 OR 4 PINS) INTERNAL CONSTRUCTION FIRST CONTACT LAYER
Open the catalog to page 14APPLICATIONS • HYBRID VEHICLES • WIND PLANTS • SOLAR POWER PLANTS • ELECTRIC ENERGY GENERATION FROM SEA WAVES • MEDICAL EQUIPMENT • INDUSTRIAL EQUIPMENT • CAR ELECTRONICS • RAILWAYS AND TURBINES (GENERATOR) • FREQUENCY INVERTERS • DC FILTERING APPLICATIONS • HIGH CAPACITANCE • SELF-HEALING PROPERTIES • HIGH RELIABILITY • LOW LOSSES • LOW DISSIPATION FACTOROF DIELECTRIC 0.1 mF UP TO 480 mF ± 5 %, ± 10 % 450 V DC, 700 V DC, 800 V DC, 900 V DC, 1100 V DC, 1300 V DC TERMINAL TO TERMINAL = 1.5xUNDC, 10 s < 1nH PER mm OF PITCH RxC > 30 000 s AFTER 1 min AT 100 V FOR UNDC < 500 V DC AT 500 V FOR...
Open the catalog to page 15GENERAL CHARACTERISTICS CAPACITANCE RANGE (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (4) TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz.
Open the catalog to page 16GENERAL CHARACTERISTICS CAPACITANCE RANGE (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (4) TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz.
Open the catalog to page 17All Iskra d.d. catalogs and technical brochures
-
POWER ELECTRONIC CAPACITORS
51 Pages
-
Strip Wound Cores
20 Pages
-
Professional Batteries
4 Pages
-
General Sales Conditions
4 Pages
-
SparkWave SDR GE
2 Pages
-
SparkWave High Speed PDH
2 Pages
-
SparkWave SDR ADM
2 Pages
-
SparkWave SDR STM
2 Pages
-
SparkWave SDR GE2
2 Pages
-
SparkLight ADM 16
2 Pages
-
SparkLight ADM 1,4
2 Pages
-
SparkLight HSP
2 Pages
-
DZ9 Catalogue
2 Pages
-
eMis
27 Pages
-
Bistable switch
26 Pages
-
Low voltage switchgear
138 Pages
-
ECU
2 Pages
-
NEO 3000
37 Pages
-
FPC 200
4 Pages
-
Radio Interfence
72 Pages
-
potentiometers
4 Pages
-
Switch disconectors
7 Pages
-
NFIF
4 Pages
-
NFIB
4 Pages
-
FI, NFI
2 Pages
-
Bistable Switches
24 Pages
-
DC-link and Snubber Capacitors
42 Pages
-
Power Factor Correction Banks
30 Pages
-
Power Electronics Capacitors
5 Pages
-
Dry Capacitors
4 Pages
-
CAU380 Bay Computer
8 Pages
-
MCE940 SCADA
4 Pages
-
NEO3000 Substation System
8 Pages
-
Energy Sector
52 Pages
-
Product line
20 Pages
-
Energy meters
44 Pages
-
Low voltage pfc
30 Pages
-
DC link capacitors and snubbers
16 Pages
-
Electrical measuring instruments
110 Pages
Archived catalogs
-
Moulded case circuit breakers
24 Pages
-
Overvoltage protection
72 Pages
-
DC link capacitors
2 Pages
-
Capacitors Selection Guide
2 Pages
-
Capacitors for electronics
44 Pages
-
Lighting capacitors
28 Pages
-
Motor capacitors
28 Pages
-
Capacitor banks - short form
4 Pages
-
Capacitor banks
32 Pages
-
Induction heating capacitors
24 Pages
-
High-voltage power capacitors
24 Pages