ENERGY SECTOR POWER ELECTRONIC CAPACITORS DC LINK CAPACITORS & SNUBBER CAPACITORS RELEVANT FOR WIND PLANTS, SOLAR POWER PLANTS, MEDICAL AND INDUSTRIAL EQUIPMENT, CAR ELECTRONICS AC/DC GENERAL PURPOSE CAPACITORS RELEVANT FOR POWER ELECTRONIC APPLICATIONS WITH HIGH CURRENT AND HARMONICS DISTORTION WITH LONG LIFE EXPECTANCY
Open the catalog to page 1CAPACITOR SELECTION GUIDE ISKRA MANUFACTURES AND SUPPLIES A WIDE RANGE OF POWER ELECTRONIC CAPACITORS WHICH CAN BE USED FOR VARIOUS FUNCTIONS IN ELECTRIC CIRCUITS. THEY ARE MOST COMMONLY USED IN FREQUENCY OR VOLTAGE INVERTERS, UNINTERRUPTIBLE POWER SUPPLIES, MOTOR DRIVES, WELDING EQUIPMENT, WIND AND SOLAR POWER SYSTEMS. A TYPICAL SWITCHING-MODE POWER SUPPLY IS SHOWN IN THE FIGURE BELOW. DC LINK CAPACITORS AT POSITION C1 ARE USED FOR DC VOLTAGE SMOOTHING. CAPACITORS AT POSITION C2 ARE SNUBBER CAPACITORS. WHEN A SWITCH OPENS, THEY ELIMINATE VOLTAGE SPIKES CAUSED BY CIRCUIT INDUCTANCE. AC FILTERING...
Open the catalog to page 2TERMS AND DEFINITIONS CN – RATED CAPACITANCE NOMINAL VALUE OF CAPACITANCE MEASURED AT 20 °C. EFFECTIVE OHMIC RESISTANCE OF THE CONDUCTOR OF A CAPACITOR UNDER SPECIFIED OPERATING CONDITIONS. UNDC – RATED DC VOLTAGE MAXIMUM OPERATING PEAK VOLTAGE OF EITHER POLARITY BUT OF A NON-REVERSING TYPE WAVEFORM FOR WHICH THE CAPACITOR HAS BEEN DESIGNED. Urms – RATED RMS VOLTAGE ROOT MEAN SQUARE OF MAX. PERMISSIBLE VALUE OF SINUSOIDAL AC VOLTAGE IN CONTINUOUS OPERATION. UN – RATED AC VOLTAGE MAXIMUM OPERATING PEAK RECURRENT VOLTAGE OF EITHER POLARITY OF A REVERSING TYPE WAVEFORM FOR WHICH THE CAPACITOR HAS...
Open the catalog to page 3POWER ELECTRONIC CAPACITORS APPLICATIONS WIND PLANTS FREQUENCY INVERTERS DC/AC INVERTER DC/AC INVERTER SOLAR POWER PLANTS DC (AC)/AC (DC) INVERTER DC (AC)/AC (DC) INVERTER DC (AC)/AC (DC) INVERTER HYBRID VEHICLES WELDING EQUIPMENT IGBT MODULE
Open the catalog to page 4DC LINK CAPACITORS TYPE KNG2047 - KNG3047, KNG2048 - KNG3048 APPLICATIONS HYBRID VEHICLES WIND PLANTS ELECTRIC ENERGY GENERATION FROM SEA WAVES MEDICAL EQUIPMENT INDUSTRIAL EQUIPMENT CAR ELECTRONICS RAILWAYS AND TURBINES (GENERATOR) FREQUENCY INVERTERS ELEVATORS WELDERS REFERENCE STANDARDS IEC 61071 UL 810 (CONSTRUCTION ONLY) FILE No.: E196169 USED IN DC-LINK CIRCUITS, CAN REPLACE ELECTROLYTIC CAPACITOR LOW ESR, HIGH RIPPLE CURRENT HANDLING CAPABILITIES LOW ESL SELF-HEALING PROPERTIES LONG LIFETIME SPECIFICATIONS CAPACITANCE RANGE CAPACITANCE TOLERANCE RATED VOLTAGE UNDC DIELECTRIC LOSS FACTOR...
Open the catalog to page 5DC LINK CAPACITORS TYPE KNG2047 - KNG3047, KNG2048 - KNG3048 GENERAL CHARACTERISTICS CAPACITANCE RANGE UNDC (V DC)
Open the catalog to page 6CONSTRUCTION DIELECTRIC: POLYPROPYLENE FILM CAPACITOR ELECTRODES: VACUUM-DEPOSITED METAL LAYERS (WITHOUT OVERPRESSURE DEVICE) CASING: CYLINDRICAL ALUMINIUM CASE WITH PLASTIC SELF-EXTINGUISHING SEALING COVER (UL 94 V-0) FILLING: EPOXY RESIN DRY (UL94 V-0) TERMINALS: M6x10 INTERNAL THREADS (TYPES KNG2047, KNG3047) - MAX. TORQUE 5 Nm M8 SCREW (TYPES KNG2048, KNG3048) - MAX. TORQUE 6 Nm BASE STUD: M12x16 - MAX. TO
Open the catalog to page 7HIGH POWER DC LINK CAPACITORS TYPE KNG4910, KNG4914 APPLICATIONS SWITCHING MODE POWER SUPPLIES (SMPS) WIND PLANTS SOLAR POWER PLANTS MOTOR DRIVES INDUCTION HEATERS FREQUENCY INVERTERS UNINTERRUPTIBLE POWER SUPPLIES (UPS) REFERENCE STANDARD SELF-HEALING PROPERTIES HIGH RIPPLE CURRENT HIGH RELIABILITY VERY LOW LOSSES SPECIFICATIONS RATED CAPACITANCE CAPACITANCE TOLERANCE RATED VOLTAGE UNDC TEST VOLTAGE (BETWEEN TERMINALS) INSULATION RESISTANCE BETWEEN TERMINALS RxC ≥ 30 000 s AFTER 1 min AT 100 V FOR UNDC < 500 V DC AT 500 V FOR UNDC ≥ 500 V DC OPERATING TEMPERATURE RANGE CLIMATIC CATEGORY LIFE...
Open the catalog to page 8HIGH POWER DC LINK CAPACITORS TYPE KNG4910, KNG4914 GENERAL CHARACTERISTICS CAPACITANCE RANGE UNDC @ 85 °C = 250 V DC, Uop@ 70 °C = 300 V DC Dimensions (mm) H W P NOTES: (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (2) (3) NOMINAL DIMENSIONS. MAXIMUM tan(δ) VALUES MEASURED AT 1 kHz. TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz.
Open the catalog to page 9HIGH POWER DC LINK CAPACITORS TYPE KNG4910, KNG4914 GENERAL CHARACTERISTICS CAPACITANCE RANGE UNDC @ 85 °C = 300 V DC, Uop@ 70 °C = 450 V DC Dimensions (mm) H W P NOTES: (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (2) (3) NOMINAL DIMENSIONS. MAXIMUM tan(δ) VALUES MEASURED AT 1 kHz. TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz. MAXIMUM R.M.S. CURRENT AT 10 kHz, θamb
Open the catalog to page 10HIGH POWER DC LINK CAPACITORS TYPE KNG4910, KNG4914 GENERAL CHARACTERISTICS CAPACITANCE RANGE UNDC @ 85 °C = 450 V DC, Uop@ 70 °C = 630 V DC Dimensions (mm) H W P NOTES: (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (2) (3) NOMINAL DIMENSIONS. MAXIMUM tan(δ) VALUES MEASURED AT 1 kHz. TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz.
Open the catalog to page 11HIGH POWER DC LINK CAPACITORS TYPE KNG4910, KNG4914 GENERAL CHARACTERISTICS CAPACITANCE RANGE UNDC @ 85 °C = 630 V DC, Uop@ 70 °C = 800 V DC Dimensions (mm) H W P NOTES: (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (2) (3) NOMINAL DIMENSIONS. MAXIMUM tan(δ) VALUES MEASURED AT 1 kHz. TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz. MAXIMUM R.M.S. CURRENT AT 10 kHz, θamb =
Open the catalog to page 12HIGH POWER DC LINK CAPACITORS TYPE KNG4910, KNG4914 GENERAL CHARACTERISTICS CAPACITANCE RANGE UNDC @ 85 °C = 750 V DC, Uop@ 70 °C = 900 V DC Dimensions (mm) H W P NOTES: (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (2) (3) NOMINAL DIMENSIONS. MAXIMUM tan(δ) VALUES MEASURED AT 1 kHz TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz. MAXIMUM R.M.S. CURRENT AT 10 kHz, θamb =
Open the catalog to page 13HIGH POWER DC LINK CAPACITORS TYPE KNG4910, KNG4914 GENERAL CHARACTERISTICS CAPACITANCE RANGE UNDC @ 85 °C = 875 V DC, Uop@ 70 °C = 1050 V DC Dimensions (mm) H W P NOTES: (1) CAPACITANCE VALUE MEASURED AT 1 kHz. INTERMEDIATE CAPACITANCE VALUES AVAILABLE ON REQUEST. (2) (3) NOMINAL DIMENSIONS. MAXIMUM tan(δ) VALUES MEASRED AT 1kHz. TYPICAL EQUIVALENT SERIES RESISTANCE AT 10 kHz. MAXIMUM R.M.S. CURRENT AT 10 kHz, θamb
Open the catalog to page 1420 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
27 Pages
26 Pages
138 Pages
2 Pages
37 Pages
4 Pages
72 Pages
4 Pages
7 Pages
4 Pages
4 Pages
2 Pages
24 Pages
42 Pages
20 Pages
30 Pages
5 Pages
4 Pages
8 Pages
4 Pages
8 Pages
52 Pages
44 Pages
30 Pages
16 Pages
110 Pages
49 Pages
44 Pages
28 Pages
2 Pages
28 Pages
4 Pages
24 Pages
32 Pages
24 Pages
2 Pages
24 Pages
72 Pages