video corpo

NEO 3000
37Pages

{{requestButtons}}

Catalog excerpts

NEO 3000 - 1

Substation Automation and Protection Energy Sector PRODUCT CATALOGUE

Open the catalog to page 1
NEO 3000 - 2

FPC 680 Multifunctional feeder terminal 11 FPC 680i Multifunctional industrial numerical relay 18 FPC 200 Family of multifunctional numerical relays 20 SCU 810 with IEC 61850 - System Communication Unit 34

Open the catalog to page 2
NEO 3000 - 4

Introduction The supply of electrical energy occupies an important position in the life of modern society. Operation of commerce, industry, transport, health service and private household are all dependent on regular and dependable supply of electrical energy. The quality of supplied electrical energy also depends on information about the state of power system. A successful power system operation therefore requires the use of state-of-the-art secondary equipment, which enables protection, monitoring, supervision and control of individual devices as well as whole power system. Tradition,...

Open the catalog to page 4
NEO 3000 - 5

FPC 680 Multifunctional Feeder Terminal FPC 680 multifunctional feeder terminal is electronic device that comprise wide range of functions for protection and control of medium or low voltage feeders. Different types of modules are available to provide the complete solution for medium or low voltage switchgear protection and also backup protection of transformers and transmission lines. FPC 680 is IEC 61850 certified by KEMA (Level A) independent laboratories. Communication • Communication via fiber optic or RJ45 Ethernet (optional serial communication - RS232, RS485 or optical) • Front...

Open the catalog to page 5
NEO 3000 - 6

synchro check breaker failure voltage inputcurrent input 1, 3 number of phases Main features Total feeder protection functionality Phase, earth-fault and negative sequence overcurrent with definite and inverse time directional/non-directional protection elements. Over/under-voltage, over/underfrequency, thermal overload protections and auto-recloser function. Complete feeder control Local and remote control of feeder switching elements applied through configurable interlocking. Measurements and energy metering Complete range of voltage, current, frequency, active and reactive power and...

Open the catalog to page 6
NEO 3000 - 7

CAU 380 Bay Computer CAU 380 bay computer is designed for data acquisition, processing and transmission of process data as well as for local automation tasks in the substations. Modular design, scalability and PQM functions are the essential qualities to meet the novel power system control standards. Various models of different sizes and functionality are available. CAU 380 is IEC 61850 certified by KEMA (Level A) independent laboratories. KEMA Control • internal data acquisition • external data acquisition (switching elements, alarm devices) - up to 110 DI • power relay outputs - up to 24...

Open the catalog to page 7
NEO 3000 - 8

NEO 3000 Substation System IEC 61850 Certificate Level A by KEMA CAU 36X Series Remote Terminal Unit CAU 36X is a family of devices intended for use in Distribution Automation Systems. The device combines all functions of feeder data acquisition, data processing, loadbreak switch control and communication functions. The most distinctive advantage of the CAU 36X devices is their built-in over-current and earth-fault detection functions. Faults on the feeder are detected by means of protection-class algorithms that are based on Digital Signal Processing technology. In order to prevent false...

Open the catalog to page 8
NEO 3000 - 9

NEO 3000 Substation System MCE 940 SCADA MCE 940 is used for real time process monitoring and control on different control levels, specially designed for power utilities. Control over the system is granted with real time interactive power system display that comprehends voltage, current and demand metering. Control secured by interlocking, events presented with single or group alarms and continuous archiving of historical data into the database are the most common features of the MCE 940 SCADA. Statistical data of protection relays and circuit breakers are stored in the database and can be...

Open the catalog to page 9
NEO 3000 - 10

SCU 810 with IEC 61850 - System Communication Unit The SCU 810 module is a complex communication device intended for the interconnection of any intelligent electronic device (IED) of Iskra Sistemi's NEO 3000 (NEO 2000) Substation Control and Protection System and of any third-party vendors. IED is considered as numerical protection relay, bay computer, intelligent RTU, energy counter and alike, that is used within the substation. The SCU 810 device covers communication functions needed within substation and functions of data handling, world time synchronization and substation automation. It...

Open the catalog to page 10
NEO 3000 - 11

Energy Sector FPC 680 Multifunctional feeder terminal

Open the catalog to page 11
NEO 3000 - 12

FPC 680 Multifunctional feeder terminal Description FPC 680 is a comprehensive and cost effective feeder management IED for protection, control, measuring and supervision of utility and industrial distribution substations. FPC 680 is a member of NEO3000® Substation system and a part of FPC protection and control product series. FPC 680 also features necessary control functions constituting an ideal solution for feeder bay control. The FPC 680 support the IEC 61850 substation automation standard including horizontal GOOSE communication offering seamless connectivity to substation automation...

Open the catalog to page 12
NEO 3000 - 13

FPC 680 provides complete range of protection functions for medium voltage switchgear, motors and transformers, Phase and earth overcurrent protection (50, 50N, 51, 51N) Overcurrent protection is based on measurements of phase and residual currents (or calculation zero sequence current from symmetrical components), Three stages can be set independently to definite time or inverse-time (IEC) characteristics, Inrush restraint or cold load pickup is applied for all overcurrent stages using set time or via binary input blocking, Phase and earth directional overcurrent protection (67, 67N) Phase...

Open the catalog to page 13
NEO 3000 - 14

synchro check breaker failure voltage inputcurrent input 1, 3 number of phases Application • Control and protection of medium voltage distribution and industrial overhead or cable feeders, bus couplers, motors and transformers • Suitable for solidly earthed, resistor earthed, Petersen-coil compensated and insulated power networks • Backup protection for power lines, power transformers and busbars of all voltage levels Control and monitoring FPC 680 is much more than just a powerful numerical relay because it also comprehends all the control functions that perfect IED for integration in...

Open the catalog to page 14

All Iskra d.d. catalogs and technical brochures

  1. eMis

    27 Pages

  2. ECU

    2 Pages

  3. FPC 200

    4 Pages

  4. NFIF

    4 Pages

  5. NFIB

    4 Pages

  6. FI, NFI

    2 Pages

  7. MCE940 SCADA

    4 Pages

  8. Energy Sector

    52 Pages

  9. Product line

    20 Pages

  10. Energy meters

    44 Pages