1. Catalogs
  2. Iskra d.d.
  3. Induction heating capacitors
video corpo

Induction heating capacitors
1 /24Pages

Induction heating capacitors

Induction heating capacitors
1 /24Pages

Catalog excerpts

Induction heating capacitors-1

High Voltage Power Induction Heating

 Open the catalog to page 1
Induction heating capacitors-2

Iskra Kondenzatorji

 Open the catalog to page 2
Induction heating capacitors-3

General information on Iskra Capacitors Type Page Induction heating capacitors KLS 4 WATER COOLED CAPACITORS 180-10000 Hz 7 High voltage power capacitors KLV 13 High voltage power capacitors with two outputs KLV xxx4 18 SINGLE-PHASE CAPACITORS WITH TWO OUTPUTS 19 Iskra Kondenzatorji

 Open the catalog to page 3
Induction heating capacitors-4

Induction heating capacitors KLS loss KLS capacitor units is ALL-FILM capacitor sections environmentally compatible designed for inductive heat generating plants operating at request, these capacitors are designed to comply with the specific requirements of each customer. Most of these capacitors provide for step changes in kvar by virtue of terminated sections within each unit. This allows for the tuning of the circuit for changing inductive loads. polypropylene film and aluminum foil construction with NON- impregnating fluid M/DBT and textured polypropylene film have exceptional dielectric...

 Open the catalog to page 4
Induction heating capacitors-5

Quality Assurances following routine tests: • Sealing test on container. • Short circuit discharge test discharge, for internally fused • Capacitance measurements. • Voltage test between terminals • Voltage test terminals to container where applicable. Capacitors comply with EC Iskra Kondenzatorji

 Open the catalog to page 5
Induction heating capacitors-6

1. For output and voltage outside this range, please contact factory. Case sizes are typical and actual sizes will be confirmed at the time of order. Arrangement of bushings shown are for reference only 2. Power at 60 Hz = 1,2 times power at 50 Hz. Iskra Kondenzatorji

 Open the catalog to page 6
Induction heating capacitors-7

WATER COOLED CAPACITORS, 180-10000 Hz Picture 2 - Single Cooling Coil Capacitor (Insulated Poles, "DeacTCase) cooling coils pressure switch Cooling coil Common terminals with

 Open the catalog to page 7
Induction heating capacitors-8

Single cooling coil capacitors (typical sizes) 1. For output, frequency and voltage outside this range, please contact factory. Case sizes are typical and actual sizes will be confirmed 2. Arrangement shown are typical. Arrangements available are from 1 to 8 taps. Iskra Kondenzatorji

 Open the catalog to page 8
Induction heating capacitors-9

Picture 3 - Single Cooling Coils Capacitor ("Live" Case) Picture 4 - Double Cooling Coils Capacitor Iskra Kondenzatorji

 Open the catalog to page 9
Induction heating capacitors-10

Double cooling coil capacitors 1. For output, frequency and voltage outside this range, please contact factory. Case sizes are typical and actual sizes will be confirmed Iskra Kondenzatorji

 Open the catalog to page 10
Induction heating capacitors-11

Internal devices Number of terminals, connection Iskra Kondenzatorji

 Open the catalog to page 11
Induction heating capacitors-12

Ordering data: When ordering, please state: While every care is taken to ensure that the information contained in this publication is correct, no legal reserves the right to alter or modify the information contained herein at any time in the light of technical or other developments. Iskra Kondenzatorji

 Open the catalog to page 12
Induction heating capacitors-13

High voltage power capacitors KLV capacitor sections, improved connections between sections and impregnation with environmentally reactive power compensation of electrical networks and industrial plants. When required voltages are higher then rated voltage of individual capacitor, units are integrated into banks by means of series connection. Fusing is provided according to national requirements. Owing to high partial discharge inception voltage, KLV capacitors networks with higher harmonics and transient voltages. Low temperature- dependent capacitance change makes them particularly suitable...

 Open the catalog to page 13
Induction heating capacitors-14

Single-phase capacitors terminal clamps * Dimensions with an asterisk (*) refer to internally fused capacitors 1) Internal fuses recommended 2) For output and voltage outside this range, please contact factory 3) Case sizes are typical and actual sizes will be confirmed at the time of order 4) Dim A may expand up to 115 % due to thermal flexure Iskra Kondenzatorji

 Open the catalog to page 14
Induction heating capacitors-15

Table I: Single-phase capacitors, 50 Hz standard units Iskra Kondenzatorji

 Open the catalog to page 15
Induction heating capacitors-16

Three-phase capacitors Picture 2 (dimensions in mm) Picture 3 (dimensions in mm) Iskra Kondenzatorji

 Open the catalog to page 16
Induction heating capacitors-17

Table II: Three-phase capacitors, 50 Hz standard units 1) For output and voltage outside this range, please contact factory 2) Case sizes are typical and actual sizes will be confirmed at the time of order 3) Internally fused capacitors on demand 4) Pressure switch on demand 5) Either 2 or 4 fixing brackets are used, depending on the height of the unit. Special bracket positions can be provided if required Please specify at the enquiry stage. 6) Dim A may expand up to 115 % due to thermal flexure Table III : Aplication of standard three-phase 50 Hz units at other operating voltages Values in...

 Open the catalog to page 17
Induction heating capacitors-18

High voltage power capacitors capacitor sections, improved connections between sections environmentally compatible in sets of three to provide an economical unbalance detection scheme. This is particularly capacitor banks. Dielectric: All-film Impregnating fluid: Environmentally compatible impregnating oil based on M/DBT Discharge resistor: Built in discharge resistor reduces capacitor from the crest of rated Case material/Finish: Capacitor case is made of stainless steel and coated with primer and top coat. For indoor mounting are available capacitors made of ordinary steel case, coated with...

 Open the catalog to page 18
Induction heating capacitors-19

Single-phase capacitors with two outputs Mounting slot Table IV - Power capacitors with two outputs 1) For output and voltage outside this range, please contact factory. 2) Case sizes are typical and actual sizes will be confirmed at the time of order 3) Either 2 (standard) or 4 (on demand) fixing brackets may be used. Special bracket positions can be provided if required Please specify at the enquiry stage. 4) Dim A may expand up to 115 % due to thermal flexure. Iskra Kondenzatorji

 Open the catalog to page 19
Induction heating capacitors-20

Type designation data: Internal devices Case material and finish Number of terminals, connection Production programme - polyester film capacitors, - polypropylene film capacitors, Capacitors and filters for radio interference suppression Spark suppression capacitors for motor cars Motor running &motor starting Lamp capacitors Power factor capacitors and automatic power factor banks Power factor controller Induction heating capacitors Tools and production equipment Iskra Kondenzatorji

 Open the catalog to page 20

All Iskra d.d. catalogs and technical brochures

  1. DZ9 Catalogue

    2  Pages

  2. eMis

    27  Pages

  3. Bistable switch

    26  Pages

  4. ECU

    2  Pages

  5. NEO 3000

    37  Pages

  6. FPC 200

    4  Pages

  7. NFIF

    4  Pages

  8. NFIB

    4  Pages

  9. FI, NFI

    2  Pages

  10. Product line

    20  Pages

  11. MCE940 SCADA

    4  Pages

  12. Energy Sector

    52  Pages

  13. Energy meters

    44  Pages

  14. Low voltage pfc

    30  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.