Institut für Prüftechnik Competence creates Confidence. Since 1969. Test unit for rapid crack propagation (RCP S4) According to ISO 13477 Description The RCP tester conveniently and accurately determines the critical pressure and critical temperature for rapid crack propagation in PE pressure pipes. Standard equipment Basic unit with sample containment cage up to 250 mm Three selectable strike speeds: 10, 15 and 20 m/s Parameterisation via electronic controller Options: Test kits and corresponding striker blades Test chamber/cell Assembly and disassembly equipment Simple and safe operation Protection of the operator by operating the controller ou side the hazardous area (e.g. behind a suitable protectiv wall at a safe distance from the tester frame) or outside the test room Acoustic and visual signals Easy connection of the sample via quick-release plug coupling Easy to replace sample supports Automatic reduction in pressure at the end of the test Reliable test results Measurement of the precise strike speed of the blade via a photoelectric barrier The automatic procedure guarantees that the test is performed well within in the specified testing time Lasting efficiency Motor-operated test unit © 2016 IPT Institut für Prüftechnik Gerätebau GmbH & Co. KG – Photos: IPT – Version: 08/16 – Data subject to change. All rights reserved. IPT Institut für Prüftechnik Gerätebau GmbH & Co. KG, Schulstr. 3, 86447 Todtenweis, Germany – ipt@iptnet.org

Open the catalog to page 1
Test Unit for Rapid Crack Propagation (RCP/S4-Test) - 2

Institut für Prüftechnik Competence creates Confidence. Since 1969. Model no. 1629 Test unit for rapid crack propagation (RCP S4) Sample dimensions Speed of the striker blade 3 selectable speeds (10, 15, 20 m/s); generated via pressure springs tensioned by an electric motor Regulation of filling pressure Manually via pressure reducer Regulation of test pressure Pressure transducer Absolute measuring accuracy 0.5% of full scale of pressure transducer Electronic controller Pressure adjustment Freely selectable Display of filling pressure Display of test pressure On control panel display From...

Open the catalog to page 2
Test Unit for Rapid Crack Propagation (RCP/S4-Test) - 3

Institut für Prüftechnik Competence creates Confidence. Since 1969. Accessories Product Model no. 1629 Test unit for rapid crack propagation (RCP S4) Description Cooling cabinet © 2016 IPT Institut für Prüftechnik Gerätebau GmbH & Co. KG – Photos: IPT – Version: 08/16 – Data subject to change. All rights reserved. IPT Institut für Prüftechnik Gerätebau GmbH & Co. KG, Schulstr. 3, 86447 Todtenweis, Germany – ipt@iptnet.org –

Open the catalog to page 3

All IPT Institut für Prüftechnik Gerätebau GmbH & Co. KG catalogs and technical brochures

  1. H3002

    2 Pages

  2. Test oven

    3 Pages

  3. H3019

    7 Pages

  4. H3047

    2 Pages

  5. 1653

    3 Pages

  6. 1411

    2 Pages

  7. 1291

    2 Pages

  8. 1665

    2 Pages

  9. H3000

    2 Pages

  10. 1643

    3 Pages

  11. FNCT Tester

    2 Pages