TANGENTIAL BY-PASS BLOWER BT00000041
3Pages

{{requestButtons}}

Catalog excerpts

TANGENTIAL BY-PASS BLOWER BT00000041 - 1

TANGENTIAL BY-PASS BLOWER 1450W two stages – a.c. brush motor Rated voltage Rated frequency Rated current Rated input power Rated speed Max air flow① Static pressure① Max noise Note: Max air power Max efficiency Operating temperature Quality of air handled IP rate Pollution degree Type of service Life②⑤⑥⑦⑧ Motor ref. ≥ 330 W ≥ 26 % from 0°C to +40°C See notes ③④ and ⑤ IP 00 2 (IEC 60664-1)⑧ S2, S3 and S4 (intermittent) ≥ 1000 h Y4Z-A44-029 at rated voltage and frequency, the data are referred to standard air condition of 23±2°C, 50±5% relative humidity and 86-106kPa pressure rated voltage and frequency, Ø16mm orifice, duty cycle 14.5 min ON / 0.5 min OFF. Run till carbon brush wear out ③ Equipment has to be operate with the working air separated from the motor ventilating air ④ The equipment is designed to handle air clean and dry only ⑤ To avoid motor overheating, accelerated brushes consumption or collector damage, it is requested that the motor ventilating air has to be clean and dry ⑥ For shorter duty cycle than at point ②, we recommend to use a soft start system to avoid a drastic reducing the life of motor brushes ⑦ Life value is for the motor only, not for the emc filter ⑧ Pollution degree 2 – only non-conductive pollution occurs, except occasionally a temporary conductivity caused by condensation is to be expected ② at Drawing Silicone gasket 1,5mm thickness O 7,2 5 (3x) Technical features and materials Insulation Class Appliance Class Dielectric strength test Motor protection Plastic parts Housing Impeller Motor bearing Gasket Electrical wires Motor cover Exhaust air and brackets - Zamak alloy Inlet air – painted metal sheet with pipe Two by aluminium sheet, 8 blades each Ball bearings sealed type Made by silicone UL 1330

Open the catalog to page 1
TANGENTIAL BY-PASS BLOWER BT00000041 - 2

TANGENTIAL BY-PASS BLOWER 1450W two stages – a.c. brush motor Electrical connection and wiring diagram Power connector Wires protected with PVC tube and with sleeves Plug slots Wire colour Function Wires White L 20AWG Yellow/Green PE 310mm length Black N a) To avoid conducted emission, the tangential by-pass blower must be connected to the EMC filter with characteristics as on the following wiring diagram (ref. products: F.NC16.10.474.472.A made by Arcotronics; YT16TA3 made by Actronic or an equivalent product): a) To avoid flickering problem, in accordance with the EN 61003-11, the max...

Open the catalog to page 2
TANGENTIAL BY-PASS BLOWER BT00000041 - 3

TANGENTIAL BY-PASS BLOWER 1450W two stages – a.c. brush motor Performance curves Average motor performance from a large production. The individual performance could be vary due to the normal manufacturing tolerances within the rated data reported on the first page.

Open the catalog to page 3