Catalog excerpts
EXHAUST BLOWER Airtight version Impeller Ø125x30mm – metal housing output Ø80mm CCW Rated voltage Rated frequency Rated current Rated power Speed ① Max air flow Max static pressure Noise ② Operating voltage Operating temperature Hot gas temperature Operating humidity Rotation IP rate Type of service Config. Ref. 100 V – 240 V from -20°C to +80°C 300 °C max 10 – 90 % R.H. (no condensation) CCW (look at the impeller) IP 00 S1, S8 (continuous) L12502 Note: ① At max air flow condition. ② Sound pressure level at 1m and max air flow condition Drawing Pressure Prob. Ø6mm cover by silicon cap 49,5 Ground Terminal Electrical and mechanical characteristics Insulation Class Class H Appliance Class Class 0I Capacitor value ③ Dielectric strength test 1800V 50Hz for 1 s Thermal protector 145°C Casing Impeller Ball bearing Damper washer Electrical wires Material list Aluminized steel Stainless steel AISI 430 626Z 19x6x6mm shielded Silicon rubber - Note: ③ the capacitor is not supplied, unless otherwise agreed. Capacitor has to be in compliance with IEC EN 60252-1. The choice of S2 type (aluminium body) covers also the requests of 24.8 chapter of IEC EN 60335-1 standard, without have to apply the minimum distance required between the capacitor and the non-metallic parts. This revision replaces all previous versions of this document. IPC has done every effort to ensure that all information in this document is complete and correct at the time of publication. Due to possible product improvements, we reserve the right to change certain data in this document without pr
Open the catalog to page 1EXHAUST BLOWER Airtight version Impeller Ø125x30mm – metal housing output Ø80mm CCW Electrical connection and wiring diagram Electrical connections: Power: No. 2 male spade terminals 6,3x0,8mm on the bobbin of motor Grounding: male spade terminal 6,3x0,8mm on the stator of motor Tachometer connection: as PCB headers KK254 Molex series. Square pins 0,64mm 2,54mm pitch Pin Nr Function External components IN OUT 1 Vcc 5V – 20V Resistor so that the current will be Hall sensor within 0,5mA – 2mA max 3 Vout Output tachometer signal connection (1pulse/rev) Vout = Vcc 2 Gnd 0V Standard applied Low...
Open the catalog to page 2All IPC catalogs and technical brochures
-
CENTRIFUGAL FAN CFH21203H501
2 Pages
-
CENTRIFUGAL FAN CFH21203H401
2 Pages
-
EXHAUST BLOWER AVFLVIS001
3 Pages
-
EXHAUST BLOWER BLXMS00031
2 Pages
-
EXHAUST BLOWER BLH2A150202
2 Pages
-
CROSS FLOW FAN CRW2A624BRC2
1 Pages
-
GEARBOX MOTOR GMF215D901
2 Pages
-
GEARBOX MOTOR GMF220D801
2 Pages
-
CENTRIFUGAL FAN CFX2131901
2 Pages
-
CENTRIFUGAL FAN CFX2130702
2 Pages
-
CENTRIFUGAL FAN CFH2080804
2 Pages
-
CENTRIFUGAL FAN CBX4190411
2 Pages
-
Micro Motion Systems
64 Pages
-
EXHAUST BLOWER AVFLVALD22
3 Pages
-
EXHAUST BLOWER BLXM000003
2 Pages
-
EXHAUST BLOWER BLH2A150201
2 Pages
-
AUTOMATION PRODUCTS
10 Pages
-
HVAC-R PRODUCTS
8 Pages