EXHAUST BLOWER AVFLVALD22
3Pages

{{requestButtons}}

Catalog excerpts

EXHAUST BLOWER AVFLVALD22 - 1

EXHAUST BLOWER Airtight version Impeller Ø150x20mm – exhaust outlet Ø80mm - CW Rated voltage Rated frequency Max input current Max input power Speed ① Max air flow Max static pressure Noise ② Starting voltage Operating temperature Hot gas temperature Operating humidity Impeller rotation IP rate Type of service Config. ref. 90 Va.c. from -10°C to +90°C 250 °C (300°C peaks) 10 – 90 % R.H. (no condensation) CW (look at the impeller) IP 44 S1, S8 (continuous) FLH150/020A-1802D-3 Note: ① At max air flow condition. ② Sound pressure level at 1m and max air flow condition Electrical and mechanical characteristics Insulation Class Class B Appliance Class Class I Dielectric strength test 1800V 50Hz for 1 s Thermal protector 125°C ±5°C Capacitor value ③ 1µF/1µF 450V Casing Gasket casing Impeller Motor bearing Damper washer Electrical wires Insulated disc Material list Aluminium die casting N°2 ceramic fibre gaskets Stainless steel AISI 302 (1.4310) Ball bearings - 608MNZZ Silicone rubber UL 1330 FEP insulated AWG 22 PTFE Note: ③ the capacitor is not supplied, unless otherwise agreed. Capacitor has to be in compliance with IEC EN 60252-1. The choice of S2 type (aluminium body) covers also the requests of 24.8 chapter of IEC EN 60335-1 standard, without have to apply the minimum distance required between the capacitor and the non-metallic parts. This revision replaces all previous versions of this document. IPC has done every effort to ensure that all information in this document is complete and correct at the time of publication. Due to possible product improvements, we reserve the right to change certain data in this document without prior no

Open the catalog to page 1
EXHAUST BLOWER AVFLVALD22 - 2

EXHAUST BLOWER Airtight version Impeller Ø150x20mm – exhaust outlet Ø80mm - CW Electrical connection and wiring diagram Electrical connections: Plug housing (male) type YLP-08V with socket contacts (female) type SYF-01P, JST made Pin number 5 2 1 3 7 8 4 Wire colour Red White Black Yellow/Green Grey Blue Brown Function Hall sensor connection Motor feeding connection External components ④ Resistance 4,7kΩ Tachometer signal 1 pulse/turn Note: ④ the resistance value is for the typical input voltage of +5Vd.c. – For others voltage value (between 3,8V and 24V) the resistance has to be...

Open the catalog to page 2
EXHAUST BLOWER AVFLVALD22 - 3

EXHAUST BLOWER Airtight version Impeller Ø150x20mm – exhaust outlet Ø80mm - CW Performance curves Performance at rated voltage and constant speed Speed [rpm] Rated voltage 50Hz Max Air flow [m3/h] 155 Max Static pressure [Pa] 300 Exhaust blower - AVFLVALD24 350 constant speed 1400 rpm constant speed 2600 rpm Constant voltage 230V 50Hz This revision replaces all previous versions of this document. IPC has done every effort to ensure that all information in this document is complete and correct at the time of publication. Due to possible product improvements, we reserve the right to change...

Open the catalog to page 3

All IPC catalogs and technical brochures