CENTRIFUGAL FAN CFX2130702 - 1

CENTRIFUGAL FAN AC motor with impeller Ø133x72mm - CW Rated voltage Rated frequency Rated current Rated power Speed ① Max air flow Static pressure Noise ② Note: Starting voltage Operating temperature Storage temperature Operating humidity Impeller rotation IP rate Type of service Config. ref. 90 V from -25°C to +45°C from -30°C to +70°C 10 – 80 % R.H. (no condensation) CW (look at the impeller) IP 44 S1, S8 (continuous) FLQWA133/072A-1802D11-99 At max air flow condition. Sound pressure level at 1m and max air flow condition Electrical and mechanical characteristics Insulation Class Class F Appliance Class Class I Dielectric strength test 1800V 50Hz for 1 s Motor protection By TP 145°C Capacitor value ③ 2µF 450V Housing Impeller Motor bearing Motor support Electrical wires Material list Metal sheet black painted Galvanized steel sheet Shielded ball bearings Silicone cable 4x0,5mm2 Note: ③ the capacitor is not supplied, unless otherwise agreed. Capacitor has to be in compliance with IEC EN 60252-1. The choice of S2 type (aluminium body) covers also the requests of 24.8 chapter of IEC EN 60335-1 standard, without have to apply the minimum distance required between the capacitor and the non-metallic parts. Electrical connection and wiring diagram Electrical connections: wire stripped Wire colour Yellow/Green Black Blue Brown Motor feeding connection External components This revision replaces all previous versions of this document. IPC has done every effort to ensure that all information in this document is complete and correct at the time of publication. Due to possible product improvements, we reserve the right to change certain data in this document without prior notice. R

Open the catalog to page 1
CENTRIFUGAL FAN CFX2130702 - 2

AC motor with impeller Ø133x72mm - CW Standard applied Low Voltage Directive: EN 60335-1 EMC Directive: Emission – EN 55014-1 Immunity – EN 55014-2 Mounting positions The motor can operate at any positions. Please pay attention: the temperature around the motor must not rise over the max admissible operating temperature, also when the motor is not powered. Performance curves Volume - Input Power This revision replaces all previous versions of this document. IPC has done every effort to ensure that all information in this document is complete and correct at the time of publication. Due to...

Open the catalog to page 2

All IPC catalogs and technical brochures