1. Catalogs
  2. Interra
  3. ITR832-001 - ITR832-002 - KNX-DALI GATEWAY

ITR832-001 - ITR832-002 - KNX-DALI GATEWAY

ITR832-001 - ITR832-002 - KNX-DALI GATEWAY

ITR832-001 - ITR832-002 - KNX-DALI GATEWAY

Product catalog summary
Description: The ITR832-001 and ITR832-002 are KNX-DALI Gateway devices designed to interface between DALI and KNX installations, facilitating communication between these protocols. The ITR832-001 supports a single channel with up to 64 DALI devices, while the ITR832-002 supports dual channels with up to 128 devices.
General Functions: Both models feature a 2x16 LCD display, are short-circuit and overvoltage proof, and have a power supply range of 100-240 VAC. They include Ethernet, KNX, and USB ports, and are protected with an IP 20 rating. The devices operate within a temperature range of -5°C to 45°C and can be stored between -25°C and 55°C.
Safety Precautions & Important Notes: Installation should be performed by qualified personnel, adhering to local regulations. The devices are designed for dry locations and should be mounted on a 35 mm DIN rail. Proper cable connections and input voltage are crucial to avoid damage.
Commissioning Functions: The devices can be programmed using ETS and a web browser. They support automatic DALI device addressing, emergency lighting tests, and remote software updates. Features like presence sensor and daylight sensor connectivity will be available in future versions.
Mounting & Demounting Processes: The devices are mounted on a DIN rail by positioning them at an oblique angle and securing them with slight pressure. Demounting involves reversing this process.
Features of Connectors & Buttons: The devices include connectors for DALI bus channels, KNX programming, power input, Ethernet, and USB, along with various status LEDs and menu buttons.
Marks: The devices comply with the Electromagnetic Compatibility Directive, Low Voltage Directive, and Restricting the Use of Hazardous Substances Directive.
Device Connection Diagram: The diagrams illustrate the correct connection of phase, neutral, and ground for both single and dual-channel devices, ensuring proper DALI communication.
See more

Catalog excerpts

ITR832-001 - ITR832-002 - KNX-DALI GATEWAY-1

ITR832-001 - ITR832-002 - KNX-DALI GATEWAY DESCRIPTION COMISSIONING FUNCTIONS The ITR832-001 & ITR832-002 single and dual channel KNX-DALI • Addressing operations can be done via ETS or manual buttons as interface devices are used to provide interface between DALI and KNX installations, enabling communication between the two protocols. DALI devices (ballasts, etc. ECGs) connected to the line are supplied with the internal DALI power supply. With the ITR832-001 single-channel device up to 1x64 DALI ballasts can be connected, with the ITR832-002 dual-channel device up to 2x64 DALI ballasts can be connected. With each DALI channel, 16 groups, 16 scenarios and 64 devices can be controlled. In addition, independent emergen- short address assignment. • Assigning group adresses to ballasts via ETS without need additional software. • Faulty ballast detection. • Faulty lighting detection. • Commissioning and control via embedded web server (*). • DALI line device selection with manual button. cy lighting according to EN 62386-202 will be supported with the 2nd • Remote software update via Ethernet connection. DALI Line Output version update. Emergency lighting tests (eg function and time test) • Emergency lighting test (according to EN 62386-202 standard) (*). can be triggered via the KNX line. In addition, feedback on the KNX Power Supply Power Consumption • KNX Bus Voltage Failure Status. • KNX Voltage Recovery Status. • DALI Bus Voltage Failure Status. • DALI Voltage Recovery Status. • Ballast and / or Lighting Error. • Working log analysis with UDP. • Broadcast control can be made with manually and software. Non-flammable Product Non-flammable Product • Tunable White colour temperature control. Light Grey and White Light Grey and White • RGB and RGBW colour control. • Presence Sensor can be connected on DALI line (*). • Pushbutton switch can be connected on DALI line (*). • Daylight Sensor can be connected on DALI line (*). Short-Circuit & Overvoltage Proof DALI Line Current Con. DALI Voltage Network Type of Protection Temperature Range line can be sent. Each DALI device can be controlled by individually, group or broadcast control. SAFETY PRECAUTIONS & IMPORTANT NOTES • The device may only be installed and put into operation by a qualified GENERAL FUNCTIONS electrician or authorized personnel. • Automatic DALI Device Addressing. • • For planning and construction of electric installations the appropriate specifications, guidelines and regulations in force of the respective country have to be complied. • Special Programming: This device is designed for professional KNX * : Features will be added in second version of the device. 1/3 and DALI installation. It can be programmed by ETS and Web Browser. • Cable Connections: Ensure making correct connections for Black and Red wires. • Input Voltage: The input voltage shall be 100-240 VAC. • Installation only in dry locations and on a 35 mm DIN rail (TH 35). • For mounting only use an appropriate equipment according to IEC 60715. • Rain, liquid and aggressive gas should not allowed to be close to device. • Screw down strength is less than 0.4Nm. • Do net get AC 240 V voltage into Bus lines,

 Open the catalog to page 1
ITR832-001 - ITR832-002 - KNX-DALI GATEWAY-2

MOUNTING & DEMOUNTING PROCESSES FEATURES OF CONNECTORS & BUTTONS 4. KNX Programming Button 5. KNX Connector • First, the device is contacted to the DIN rail by holding it at an oblique angle. • Then, it is pushed slightly from above in the direction of 1st • Finally, the device is pushed slightly in the direction of 2nd arrow and placed on the DIN rail to finish the mounting. Demounting: • All values given in the device dimensions are in millimeters. • The device can be used in an area of up to 4 modules. 9. Ethernet LED 10. Error Status LED 11. Menu Mode Button 12. Menu Setting Button 13. Menu...

 Open the catalog to page 2
ITR832-001 - ITR832-002 - KNX-DALI GATEWAY-3

DEVICE CONNECTION DIAGRAM • ITR832-001 - KNX-DALI Gateway Single Channel device • ITR832-002 - KNX-DALI Gateway Dual Channel device is is supplied with 100-240 VAC mains voltage. The phase, supplied with 100-240 VAC mains voltage. The phase, neutral and ground connections are shown in the figure (L, N, tral and ground connections are shown in the figure (L, N, PE). • The positive (+) and negative (-) poles of the DALI • The positive (+) and negative (-) poles of the DALI electronic control units (ECGs) should be connected correctly electronic control units (ECGs) should be connected correctly...

 Open the catalog to page 3

All Interra catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.