Interface Catalog
236Pages

{{requestButtons}}

Catalog excerpts

Interface Catalog - 1

The Leader in Force & Torque Measurement

Open the catalog to page 1
Interface Catalog - 3

ADVANCED FORCE MEASUREMENT Load Cells

Open the catalog to page 3
Interface Catalog - 4

The Leader in Force Measurement Model 1000 Fatigue Rated Load Cell (US & Metric) • Proprietary Interface temperature compensated strain gages • 100 million fully reversed cycles • Performance to 0.03% • Eccentric load compensated • Low deflection • 0.0008%/°F (0.0015%/°C) temp. effect on output • Barometric compensation • Shunt calibration • Tension and compression Interface Inc. • 7401 East Butherus Drive • Scottsdale, Arizona 85260 USA • Phone: 480.948.5555 • Fax: 480.948.1924 www.interfaceforce.com • Email: contact@interfaceforce.com • ORDER TOLL-FREE 800.947.5598

Open the catalog to page 4
Interface Catalog - 5

The Leader in Force Measurement OPTIONS ■ STANDARD CONFIGURATIONS Base (Recommended) Bayonet Connector Multiple Bridge Standardized Output Connector Protection Transducer Electronic Data Sheet (TEDS) Mating Connector Loading Hardware 10 ft Integral Cable (10xxAJ-nn) <or> Installed Base (-B suffix) Shown with optional base. m^QrfciCE Interface Inc. • 7401 East Butherus Drive • Scottsdale, Arizona 85260 USA • Phone: 480.948.5555 • Fax: 480.948.1924 www.interfaceforce.com • Email: contact@interfaceforce.com • ORDER TOLL-FREE 800.947.5598 ADVANCED FORCE MEASUREMENT

Open the catalog to page 5
Interface Catalog - 6

The Leader in Force Measurement Model 1000 Fatigue Rated High Capacity Load Cell (U.S. & Metric) • Proprietary Interface temperature compensated strain gages • 100 million fully reversed cycles • Performance to .06% • Eccentric load compensated • Low deflection • .0008%/°F (.0015%/°C) temp. effect on output • Barometric compensation • Shunt calibration • Tension and compression Shown with optional base U.S. Models (lbf) Metric Models (kN) ACCURACY – (MAX ERROR) Static Error Band–% FS Nonlinearity–% FS Hysteresis–% FS Nonrepeatability–% RO Creep, in 20 min–% Side Load Sensitivity–% Eccentric...

Open the catalog to page 6
Interface Catalog - 7

The Leader in Force Measurement OPTIONS Base (Recommended) Integral 10 ft Cable Bayonet Connector Multiple Bridge Standardized Output Transducer Electronic Data Sheet (TEDS) ACCESSORIES Mating Connector Instrumentation Loading Hardware STANDARD CONFIGURATIONS 10 ft Integral Cable (10xxAJ-nn) PC04E-10-6P Standard Connector (10xxAF-nn) PT02E-10-6P Bayonet Connector (10xxCDS-nn) Installed Base (-B suffix) Interface Inc. • 7401 East Butherus Drive • Scottsdale, Arizona 85260 USA • Phone: 480.948.5555 • Fax: 480.948.1924 www.interfaceforce.com • Email: contact@interfaceforce.com • ORDER...

Open the catalog to page 7
Interface Catalog - 8

The Leader in Force Measurement Model 1100 Ultra Precision Load Cell (US & Metric) • Proprietary Interface temperature compensated strain gages • Performance to 0.02% • High output – to 4 mV/V • Eccentric load compensated • Low deflection • 0.0008%/°F (.0015%/°C) temp. effect on output • Shunt calibration • High precision base included • Barometric compensation • Tension and compression DIMENSIONS 1110 See Drawing Interface Inc. • 7401 East Butherus Drive • Scottsdale, Arizona 85260 USA • Phone: 480.948.5555 • Fax: 480.948.1924 www.interfaceforce.com • Email: contact@interfaceforce.com •...

Open the catalog to page 8
Interface Catalog - 9

The Leader in Force Measurement SPECIFICATIONS PARAMETERS U.S. Models (lbf) Metric Models (kN) ACCURACY – (MAX ERROR) Static Error Band–% FS Nonlinearity–% FS Hysteresis–% FS Nonrepeatability–% RO Creep, in 20 min–% Side Load Sensitivity–% Eccentric Load Sensitivity–%/in TEMPERATURE Compensated Range–°F Compensated Range–°C Operating Range–°F Operating Range–°C Effect on Zero–%RO/°F – MAX Effect on Zero–%RO/°C – MAX Effect on Output–%RO/°F – MAX Effect on Output–%RO/°C – MAX ELECTRICAL Rated Output–mV/V (Nominal) Excitation Voltage–VDC MAX Bridge Resistance–Ohm (Nominal) Zero Balance–% RO...

Open the catalog to page 9
Interface Catalog - 10

The Leader in Force Measurement Model 1101 Ultra Precision Compression-Only Load Cell (U.S. & Metric) Why the Interface model 1101 Ultra Precision Compression-Only Load Cell is the best in class: • Proprietary Interface temperature compensated strain gages • Performance to .02% • High output – to 4 mV/V • Eccentric load compensated • Low deflection • .0008%/°F (.0015%/°C) temp. effect on output • Shunt calibration • High precision base included • Barometric compensation INTERFACE • 7401 E. Butherus Drive, Scottsdale, AZ 85260 • PHONE: (480) 948-5555 • FAX: (480) 948-1924...

Open the catalog to page 10
Interface Catalog - 11

The Leader in Force Measurement SPECIFICATIONS 1111 ACCURACY – (MAX ERROR) Static Error Band–% FS Nonlinearity–% FS Hysteresis–% FS Nonrepeatability–% RO Creep, in 20 min–% Side Load Sensitivity–% Eccentric Load Sensitivity–%/in TEMPERATURE Compensated Range–˚F Compensated Range–˚C Operating Range–˚F Operating Range–˚C Effect on Zero–%RO/˚F – MAX Effect on Zero–%RO/˚C – MAX Effect on Output–%/˚F – MAX Effect on Output–%/˚C – MAX PARAMETERS U.S. Models (lbf) Metric Models (kN) ELECTRICAL Rated Output–mV/V (Nominal) Excitation Voltage–VDC MAX Bridge Resistance–Ohm (Nominal) Zero Balance–% RO...

Open the catalog to page 11
Interface Catalog - 12

The Leader in Force Measurement 1200 Standard Load Cell (U.S. & Metric) • Proprietary Interface temperature compensated strain gages • Performance to .04% • High output – to 4 mV/V • Eccentric load compensated • .0008%/°F (.0015%/°C) temp. effect on output • Low deflection • Shunt calibration • Barometric compensation • Tension and compression • Compact size MODEL 1220 CAPACITY U.S. (lbf) Metric (kN) Interface Inc. • 7401 East Butherus Drive • Scottsdale, Arizona 85260 USA • Phone: 480.948.5555 • Fax: 480.948.1924 www.interfaceforce.com • Email: contact@interfaceforce.com • ORDER TOLL-FREE...

Open the catalog to page 12

All Interface catalogs and technical brochures