This instruction manual provides essential precautions and operational guidelines for the IMS Model M5/6/8 sensors. It is crucial to read and understand these instructions to ensure safe and effective use of the product.

Safety Warnings
  • Install a fail-safe device when using the unit with machinery that could cause serious injury or economic loss.
  • Avoid using the unit over the rated voltage or in environments with flammable gases, vibration, or impact.
  • Do not clean the unit with water or oil-based detergents.

Product Features
  • Sensing methods include diffuse reflective and through-beam.
  • Models available: M5D20-N, M5T200-N, M5T200-P, M8D100-N, M8D100-P, M6D50-N, M6T500-N, M6D50-P, M6T500-P.
  • Response time is 1ms with a maximum current consumption of 20mA.
  • Power supply range is 10~30VDC.
  • Protection features include reverse polarity and output short-circuit protection.

Specifications
  • Insulation resistance: Minimum 20MΩ at 500VDC.
  • Dielectric strength: 1000VAC for 1 minute.
  • Vibration resistance: 1.5mm amplitude at 10 to 55Hz.
  • Shock resistance: 500m/s² in X, Y, Z directions.
  • Ambient conditions: Temperature -20 to 65°C, Humidity 45 to 85%.
  • Degree of protection: IEC IP64.

Installation and Usage Recommendations
  • Ensure correct wiring before powering on.
  • Use visors or hoods to prevent excessive light interference.
  • Maintain adequate spacing between multiple sensors to avoid interference.
  • Avoid direct installation on reflective surfaces.
  • Separate sensor wiring from high voltage lines.
  • Use short cables to prevent power surges.
  • Clean lenses with a dry cloth, avoiding chemical solvents.

Connection Details
  • Control output circuit diagrams are provided for both PNP and NPN open collector outputs.
  • Maximum load current is 100mA.

Contact Information
For further assistance, contact Intellisense Microelectronics at Tel: 0592-8268993 or visit www.chinasensors.cn.
See more

Catalog excerpts

Ultra Small Photoelectric Sensor M5, M6, M8 series-1

Specifications Diffuse reflective Diffuse reflective Diffuse reflective Sensing method Non-glossy white paper 100×100mm Non-glossy white paper 100×100mm Non-glossy white paper 100×100mm Light source Infrared LED Infrared LED Infrared LED Laser (850nm) (940nm) (940nm) (650nm) Power supply INSTRUCTION MANUAL Sensing object Sensing distance Current consumption Max. 20mA(No including the load) Thank for you selecting IMS product.This sheet primarily describes precautions required in installing and operating the product.Before operating the product,read Load current Operation mode the sheet thoroughly to acquire sufficient knowledge of the product.For your convience,keep the sheet at your disposal. Indicators Circuit protection Response time Operation indicator:Red,Stability indicator:Green Reverse polarity protection、output shot-circuit protection 1ms Adjustable Failure to follow these instuctions may result in serious injury or death: Sensitivity adjustment Fail-safe device must be installed when using the unit with machinery that may Ambient illumination Incandescent lamp:Max. 5,000lx/Sunlight:Max.50,000lx cause serious injury or substantial economic loss. (e.g. nuclear power control, Ambient temperature Operation:-20 ~ 65 ℃/Storage:-30 ~ 80 ℃(with no icing and condensation) medical equipment, ships, vehicles, railways, aircraft, combustion appatatus, Ambient humidity safety equipment, crime/disaster prevention devices,etc.) Insulation resistance Min. 20MΩ ( at 500VDC megger ) Failure to follow these instructions may result in product damage: Dielectric strength 1000VAC 50/60Hz for 1 minute Do not use this unit over rated voltage; Vibration resistance 1.5mm amplitude at frequency of 10 to 55Hz in each of X,Y,Z direction for 2 hours Do not use this unit where there is vibration or impact; Shock resistance In cleaning the unit, do not use water or an oil-based detergent. Do not use this unit where there is flammable or explosive gas; High performance ASIC with built-in amplifier Accessory Power on delay to prevent error trigger Optimum Choice to replace optical fiber sensor Stainless steel ※ 1:There are two types of connections for M8 sensor. Red LED、laser、Infrared LED Rejection of ambient/DC light/interference using with built in digital filter Operating timing diagram Compact size is easy for installation Reversed voltage protection, over voltage protection (Light sorce code) Connection type Response time Operation mode Cable type Connector type available Fixed Light on Dark on Selectable NPN PNP NPN+PNP 5V Relay Analog Unit:mm Unit:m Sensing distance unit Sensing distance (slot series use 30/50 to refer slot distance) Sensing method(solt series is none) Number Sensing distance T D R V B Through-beam Diffuse reflective Retro reflective Convergent reflective P-opaquing

 Open the catalog to page 1
Ultra Small Photoelectric Sensor M5, M6, M8 series-2

Connections Through-beam Emitter Power indicator Operation indicator Diffuse reflective Operation indicator(red) Stability indicator(green) Sensitivity adjuster ② Connector type Operation indicator(red) Stability indicator(green) Sensitivity adjuster Control output circuit diagram Connection cable NPN open collector output (+)Brown +V Stability (green) Operation (red) Main circuit Load (OUT)Black Output Max. 100mA Over current protection (-)Blue 0V (C)White Control PNP open collector output Stability (green) Operation (red) Main circuit (+)Brown +V Over current protection (-)Blue 0V (C)White...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.