This instruction manual provides essential guidelines for the installation and operation of the IMS E3S30 model. It emphasizes the importance of understanding the product thoroughly to ensure safe and effective use.

Safety Precautions
  • Install a fail-safe device when using the unit with machinery that could cause serious injury or economic loss.
  • Avoid using the unit over its rated voltage, in environments with flammable gases, or where there is vibration or impact.
  • Do not clean the unit with water or oil-based detergents.

Features
The E3S30 model is a high-performance photoelectric sensor with features such as:
  • High response time of 1ms or 0.25ms.
  • Power supply reverse polarity protection and output short-circuit protection.
  • Embedded transmitter and receiver for simplified installation.
  • Applicable for label detection, hole or gear edge counting.

Specifications
  • Sensing methods include through-beam, diffuse reflective, and retro-reflective.
  • Operating voltage: 10~30VDC with a load current of max. 100mA.
  • Ambient temperature range: -25 to 55°C for operation.
  • Degree of protection: IEC IP65.

Installation and Usage Guidelines
  • Ensure correct wiring before powering on.
  • Prevent excessive light from entering the sensor's inclination angle.
  • Maintain adequate spacing between multiple sensors to avoid interference.
  • Avoid direct installation on reflective surfaces to prevent malfunction.
  • Use separate wiring for sensors to prevent damage from high voltage lines.

Connection and Circuit Protection
The manual provides detailed diagrams for wiring configurations, including:
  • Four and five-wire PNP and NPN open collector outputs.
  • Overcurrent protection and stability indicators.

Contact Information
For further assistance, contact Intellisense Microelectronics at:
  • Tel: 0592-8268993
  • Email: [email protected]
  • Address: 1F NO. 34 Guanri Rd, Xiamen Software Park, Xiamen, P.R. China
See more

Catalog excerpts

E3S30-1

Model E3S30-nnan INSTRUCTION MANUAL ! WARNING Thank you for selecting IMS product.This sheet primarily describes precautions required in installing and operating the product.Before operating the product,read the sheet thoroughly to acquire sufficient knowledge of the product.For your convience,keep the sheet at your disposal. Failure to follow these instuctions may result in serious injury or death: Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control medical equipment, ships, vehicles, railways, aircraft, combustion appatatus, safety equipment, crime/disaster prevention devices,etc.) Failure to follow these instructions may result in product damage: Do not use this unit over rated voltage; Do not use this unit where there is flammable or explosive gas; Do not use this unit where there is vibration or impact; In cleaning the unit, do not use water or an oil-based detergent. Features • High performance ASIC based advance sensor • Sensitivity adjust • Red LED or infrared LED • High response time:1ms or 0.25ms • Power supply reverse polarity protection, Output short-circuit protection and over current protection • Built in self-recover output short circuit protection • The transmitter and receiver are embedded in a u-shaped housing to simplify installation and alignment • Applicable to label detection, hole or gear edge counting Sensing method □ Operating timing diagram — ( Light source code ) Connection type Response time Sensitivity Operation mode Sensing distance unit Sensing distance ( slot series use 30/50 to refer slot distance ) Sensing method ( slot series is none ) available Fixed_ Light on Dark on Selectable Number) Sensing distance ^ The waveforms of"Operation indicator"and" Transistor output"are for Light on mode.

 Open the catalog to page 1
E3S30-2

Control output circuit diagram Four wires-NPN open collector output Optical axis Load Main circuit Stability (green) Operation (red) Sensitivity adjuster Operation indicator Stability indicator (Black) output Over current protection Four wires-PNP open collector output (Brown)+V Main circuit Stability (green) Over current protection Caution for using 1、Please make sure the wiring is correct before power-on. 2、Use a visor or a hood so that excessive light(e.g. sunlight, spotlight)does not directly enter into the inclination angle of the sensor. 3、When more than 2 sets of Through-beam type sensor...

 Open the catalog to page 2

All Intellisense Microelectronics catalogs and technical brochures

  1. DSA

    1  Page

  2. T18

    2  Pages

  3. PM Series

    2  Pages

  4. SPX67 Series

    2  Pages

  5. light curtain

    2  Pages

  6. E3Z-F series

    2  Pages

  7. E3S50

    2  Pages

  8. E3S15

    2  Pages

  9. E3S10

    2  Pages

  10. E3TA Series

    2  Pages

  11. E3FA Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.