Introduction
This instruction manual provides essential precautions for installing and operating the IMS Model AS product. It emphasizes the importance of understanding the product thoroughly to ensure safe and effective use.

Safety Warnings
1. A fail-safe device is mandatory when using the unit with machinery that could cause serious injury or economic loss.
2. Avoid using the unit over its rated voltage, in environments with flammable gases, or where there is vibration or impact.
3. Do not clean the unit with water or oil-based detergents.

Features and Specifications
The product features include high-performance ASIC-based sensors, noise immunity, and various protections such as power supply reverse polarity and overload protection. The specifications cover:
  • Power supply: DC10~30V
  • Load current: Max. 100mA
  • Response time: 1.28ms to 2ms
  • Ambient conditions: Operation temperature -20 to 65°C, storage -30 to 80°C
  • Protection degree: IEC IP64


Operation Instructions
1. Ensure correct wiring before powering on.
2. Avoid direct exposure to excessive light.
3. Maintain adequate spacing between multiple sensors to prevent interference.
4. Avoid reflection from flat surfaces.
5. Use separate wiring for high voltage lines.
6. Use short cables to prevent power surges.
7. Clean the lens with a dry cloth only.

LED Indicators
The green LED indicates power at the emitter and operation at the receiver. The red LED indicates operation, and the yellow LED signals power-up and alarms.

Maintenance and Troubleshooting
1. The sensor adjusts automatically to its environment upon power-up.
2. If the yellow LED blinks continuously, restart the sensor. If unresolved, contact support.
3. Alarm output is triggered by factors like dust accumulation.
4. For noise issues, isolate high current from the sensor ground loop.

Contact Information
For technical support, contact via email at [email protected] or [email protected]. Phone: 0592-8268993.

Product Range
The company offers a variety of sensors including photoelectric, proximity, pressure, and distance sensors.
See more

Catalog excerpts

Crossing-beam light curtain AS series-1

Sensing distance Response time Power supply DC10~30V (including voltage ripple of 10%(p-p)max.) INSTRUCTION MANUAL Power (green) Current consumption Load current the sheet thoroughly to acquire sufficient knowledge of the product.For your Power (green), Alarm (yellow) Max. 60mA Power on delay, power supply reverse polarity protection, output Circuit protection short circuit protection, output reverse polarity protection Life expectancy Ambient illumination convience,keep the sheet at your disposal. Thank for you selecting IMS product.This sheet primarily describes precautions required in installing and operating the product.Before operating the product,read Power (green), Operation (red), Alarm (yellow) Incandescent lamp: Max. 5,000lx /Sunlight: Max. 50,000lx Ambient temperature Operation:-20~65 ℃/Storage:-30~80 ℃(with no icing and condensation) Failure to follow these instuctions may result in serious injury or death: Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion appatatus, Ambient humidity Operation: 35 ~ 85 %/Storage: 35%~95% (with no condensation) Production degree line Individual color definition Common Synchronous (white, red, yellow) Synchronous (white, grey) Power (brown), grown (blue), output (black) Aluminum, silver anode Failure to follow these instructions may result in product damage: Instrusction manual Do not use this unit over rated voltage; safety equipment, crime/disaster prevention devices,etc.) Do not use this unit where there is flammable or explosive gas; Do not use this unit where there is vibration or impact; In cleaning the unit, do not use water or an oil-based detergent. Control output circuit diagram NPN open collector output Features High performance ASIC based advance sensor Built in power on delay prevent false output as sensor powering up Excellent noise immunity to DC light with modulated light source and CDS signal process technology Power supply reverse polarity protection, Over load protection, and Power (green) operation (red) Alarm (yellow) Over current protection Synchronous lines Model definition Synchronous lines Cable Connector Light on Dark on Selectable NPN PNP NPN+PNP Serial port output Response time Operation mode Series+Number of optical axis *(1) Distance number, unit: mm Common light curtain Cross beam light curtain Ultra-thin cross beam light curtain Other non-standard series Number of optical axis PNP open collector output (Brown)+V Power (green) Operation (red) Alarm (yellow ) Area sensor hight number, unit: mm Effective sensing hight Sensing distance Power (green) Over current protection (Black)output Max.100mA Load (Blue) 0V Synchronous lines Synchronous lines Power (green) Alarm*(2) (yellow) Output reverse polarity protection Load (Black) output Max.100 mA

 Open the catalog to page 1
Crossing-beam light curtain AS series-2

• Common structure Caution for using 1. Please make sure the wiring is correct before power-on. 2. Use a visor or a hood so that excessive light(e.g. sunlight, spotlight) does not directly enter into the inclination angle of the sensor. 3. When more than 2 sets of light curtains are used closely, it might cause interference each other. Be sure to put enough space between them in order to avoid malfunction. 4. If the sensor is installed directly on a flat surface, the reflection off the surface may cause malfunction. Make sure there is enough space between the sensor and the surface. 5. If the...