Counting sensor PG series
1 / 1Pages

Catalog excerpts

Counting sensor PG series - 1

Specifications Model Power supply Sensing area Response time INSTRUCTION MANUAL Mini Frame Counting Sensor Power indicator (green), operation indicator (red), Alarm (yellow) Current consumption 25mA Load current Thank for you selecting IMS product. This sheet primarily describes precautions required in installing and operating the product.Before operating the product, read the sheet thoroughly to acquire sufficient knowledge of the product. For your convenience, keep the sheet at your disposal. Circuit protection Power on delay,power supply reverse polarity protection,output short-circuit protection Ambient illumination Incandescent lamp:Max. 5,000lx /Sunlight:Max. 50,000lx Failure to follow these instructions may result in serious injury or death: Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices,etc.) Failure to follow these instructions may result in product damage: Do not use this unit over rated voltage; Do not use this unit where there is flammable or explosive gas; Do not use this unit where there is vibration or impact; In cleaning the unit, do not use water or an oil-based detergent. Operation: -20 ~ 65 ℃/Storage: -30 ~ 80 ℃(with no icing and condensation) Ambient humidity Ambient temperature Operation: 45 ~ 85 %RH/Storage: 35%~95%RH(with no condensation) Protection degree Line color definition Power: brown; Ground: blue; Operation: black; Alarm: white Material Case: aluminum, black anode Suitable for all types of materials, metal or non-metal Fast Response time, down to 1ms Mini structure High performance ASIC with high immunity to EMI and environmental interference Built in algorithm to calculate the volume of passing object Multiple channels can be formed side by side with small channel spacing Fixing Off-delay function Fixing On-delay function Reset time Response time Output Accuracy/Sensitivity*(1) V:Channel spacing ,n:number(mm) Tn:channel number,no need to fill in single channel Length of sensing area,no need to fill in the ring series Width of sensing area Channel spacing Number Unit:mm Number Unit:mm CX RX EX PG Frame series Ring series Slot series Miniature *(1) :Accuracy refers to the smallest particle size to achieve no blind area detection; *(2) :Non-standard structure can be designed. Control output circuit diagram(NPN) 1 Main circiet Black 2 Load (OUT) Power Alarm Operation Over current protection White Load (Alarm) 3 Over current protection 4 Caution for using 1、The sensor has the function of automatic adjustment and can actively identify the operating environment. Please fix the sensor before power on. 2、When powered on, in the first 3 to 5 second, the yellow LED in sensor will blink – sensor is adjusting itself to optimal setting. During this period of time, do not do anything that can influence the operation of the sensor, leave the sensor to itself until the yellow LED stop blinking. If the yellow light keeping blinking for a long time without stopping, please power off the sensor and power on again. If the problem remains, this means sensor can’t adjust itself to optimal working condition. If this occurs, please contact us. 3、As the sensor’s optimal setting is influenced by its environment, after powered on, do not move sensor to another place. If you move sensor to another place, please power off and power on again. 4、The sensor has alarm output, when the sensor optimal working condition is degraded due to factors such as dust accumulated on optical window, the sensor will have alarm output – the yellow LED will light up and the Output of Red wire will changed(depends on the mode of the sensor operation). If after cleaning the optical window, the sensor still can not work, please contact us. 5、If encounting noise problem, please try to isolated high current from the sensor ground loop. Try to use start connection, ground equipment with high current directly to ground, ground the case of inductive motor to gro

Open the catalog to page 1

All Intellisense Microelectronics catalogs and technical brochures

  1. DSA

    1 Pages

  2. T18

    2 Pages

  3. PM Series

    2 Pages

  4. SPX67 Series

    2 Pages

  5. E3Z-F series

    2 Pages

  6. E3S50

    2 Pages

  7. E3S30

    2 Pages

  8. E3S15

    2 Pages

  9. E3S10

    2 Pages

  10. E3TA Series

    2 Pages

  11. E3FA Series

    2 Pages