This document is an instruction manual for the IMS E3T photoelectric sensor. It provides essential precautions for installation and operation to ensure safety and optimal performance.

Safety Precautions
  • Install a fail-safe device when using the sensor with machinery that could cause serious injury or economic loss.
  • Avoid using the unit over its rated voltage, in environments with flammable gases, or where there is vibration or impact.
  • Do not clean the unit with water or oil-based detergents.

Specifications
  • Control box includes LED indicators for sensor output and transmission power adjustment.
  • Keys are provided to increase or decrease transmitting power.
  • Output options include NPN and PNP open collector outputs.
  • Power supply: 10-30VDC, with a maximum current consumption of 20mA.
  • Environmental resistance includes IP64 protection, vibration, and shock resistance.

Operation Instructions
  • Short and long press functions for adjusting transmitting power, with settings saved to EEPROM.
  • Ensure correct wiring before powering on and avoid direct exposure to excessive light.
  • Maintain adequate spacing between sensors to prevent interference.

Installation and Adjustment
  • Ensure the sensor's sensing surface is parallel to the object surface.
  • Use M2 screws with a tightening torque under 0.3N.m for mounting.
  • Adjust the sensor position to determine the optimal operation area.

Connection and Wiring
  • Follow specific wiring instructions for NPN and PNP outputs.
  • Avoid wiring with high voltage lines to prevent damage or malfunction.
  • Use short cables to prevent power surges.

Additional Information
  • Contact details for Intellisense Microelectronics are provided for further assistance.
See more

Catalog excerpts

Compact Photoelectric Senor E3T series-1

E3T-DDDD Compact Photoelectric Sensor INSTRUCTION MANUAL ! WARNING Thank you for selecting IMS product.This sheet primarily describes precautions required in installing and operating the product.Before operating the product,read the sheet thoroughly to acquire sufficient knowledge of the product.For your convenience,keep the sheet at your disposal. Failure to follow these instructions may result in serious injury or death: Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices,etc.) Failure to follow these instructions may result in product damage: Do not use this unit over rated voltage; Do not use this unit where there is flammable or explosive gas; Do not use this unit where there is vibration or impact; In cleaning the unit, do not use water or an oil-based detergent. C — ( Light source code ) Connection type Response time Operation mode Sensing method Sensing distance unit Sensing distance ( slot series use 30/50 to refer slot distance ) Sensing method ( slot series is none ) Number) Sensing distance Photoelectric sensor □ Control output circuit diagram 0 NPN open collector output □ Control box © Functions of indicators and keys • LED1:sensor output status • LED2:transmission power adjustment status • Key1:Increase the transmitting power • Key2:Reduce the transmitting power © Operation instruction • Short press keyl one time:Increase the transmitting power slightly. When the power up to the maximum, LED2 will blink at an interval of 0.25s. • Short press key2 one time:Decrease the transmitting power slightly. When the power down to the minimum, LED2 will blink at an interval of 0.5s. • Long press key1:When the long press time reaches 2s, the transmitting power will continue to increase. The voltage will no longer change after release the button. When the LED2 flashing, it means the power reaches the maximum. • Long press key2:When the long press time reaches 2s, the transmitting power will continue to decrease. The voltage will no longer change after release the button. When the LED2 flashing, it means the power reaches the minimum. • Save setting:The parameter will be automatically saved to EEPROM and does not need to be set next power on. © PNP open collector output

 Open the catalog to page 1
Compact Photoelectric Senor E3T series-2

• Diffuse reflective □ Mounting & Adjustment Installation • Confirm that the sensing surface of sensor is parallel with the surface of each sensing object. ^l:Load connection for NPN output; ^2:Load connection for PNP output; • Please use screw M2 to mount the sensor,set the tightening torque under 0.3N.m. 4-M2 Tap □ Operating timing diagram Operation mode ^ The waveforms of"Operation indicator"and" Transistor output"are for Light on mode □ Dimensions • Through-beam type ( Emitter) Diffuse reflective type OPR:Operation STB:Stability • When installing the sensor, please refer to the direction...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.