1. Catalogs
  2. INTEGRA Metering AG
  3. DOMINO For chemical liquids

DOMINO For chemical liquids

DOMINO For chemical liquids
1 / 28 PagesView full catalog

DOMINO For chemical liquids

Product catalog summary
Applications
Flow measurement of liquids is utilized in industries such as chemical, pharmaceutical, and cosmetic, as well as in batching and filling operations.
Benefits
The system offers flexible mounting, minimal space requirements, suitability for both conductive and non-conductive liquids, and is unaffected by flow disturbances. It ensures long life with low maintenance.
DOMINO System Overview
The DOMINO system is a modular flow measurement concept suitable for both safe and hazardous areas (ATEX), including a range of flow sensors, displays, pulsers, and batching controls.
Flowmeter Types
  • ARD Rotary Piston Flowmeters: Suitable for high viscosity liquids, with a measuring error limit of ±0.5%.
  • AMD Vane Wheel Flowmeters: Suitable for low viscosity liquids, with a measuring error limit of ±2%.
  • PMD Vane Wheel Flowmeters: Primarily for water and non-aggressive low-viscosity fluids, with a measuring error limit of ±2%.
Operation Principles
The ARD range operates on a volumetric principle with rotary pistons, while the AMD and PMD series use a velocity measuring principle with a multi-jet vane wheel. Both types are insensitive to flow disturbances and do not require a power supply.
Design Features
The ARD range features rotary pistons, guide rollers, and a carrier as the only moving parts in contact with the liquid. The AMD and PMD series have a vane wheel as the only moving part, ensuring long-term stability and precision.
Technical Data
Flowmeters are available for various nominal diameters and pressures, with fluid temperatures up to 180°C. They are suitable for different viscosities and can be installed horizontally or vertically.
Pressure Drop Curves
Pressure drop curves are provided for different nominal diameters and viscosities, with recommended and admissible pressure drop limits.
Accreditations
All DOMINO components, except the RV ancillary groups, are certified according to the ATEX Directive 94/9/EC.
DOMINO AMD Vane Wheel Flowmeters
  • Specifications: Designed for chemical liquids with viscosities up to 4 mPa·s, suitable for horizontal installation with dial upward. Operating temperature ranges are 90 °C and 180 °C, with a rated pressure of PN 25.
  • Performance: Measuring error limits are ±2% of the effective value, with repeatability at ±0.3%.
  • Materials: Constructed from corrosion and acid-resistant steel (CrNiMo).
  • Flow Rates: Maximum flow rates are 5000 l/h for DN 25 and 12000 l/h for DN 40.
  • Additional Features: Compatible with all DOMINO modules and certified according to ATEX Directive 94/9/EC.
DOMINO PMD Vane Wheel Flowmeters
  • Specifications: Primarily used for water flow measurement or dosing, featuring a brass housing with threaded connections.
  • Performance: Measuring tolerances are ±2% of the effective value, with repeatability at ±0.3%.
  • Materials: Housing made of brass, measuring unit from PPO plastic, and seals from EPDM.
  • Flow Rates: Maximum flow rates range from 5000 l/h for DN 20 to 20000 l/h for DN 40.
  • Additional Features: Available with modules "pulser with roller register" or "installation for batching control".
System Planning and Installation
  • Installation Guidelines: Ensure the flowmeter is always full of liquid and no air or gas can enter. Meters should be easily accessible for reading and not installed facing downwards.
  • Selection Criteria: Meters and auxiliaries must be chosen based on operating pressure, temperature, material resistance, and flow capacity.
  • Safety Measures: Install shut-off valves downstream to prevent return flow and emptying. Use dirt traps or prefilters to protect the flowmeter from damage.
Remote Evaluation and Pulse Transmission
  • Pulse Transmission: Pulsers are available for remote evaluation, generating one pulse per volumetric unit.
  • Electrical Installation: Must comply with legal regulations, especially in explosion-risk zones. Professional electricians should handle all cabling.
Ordering Information
  • ARD Sensors: Various type designations and order numbers are available for standard and special versions, with different housing and seal materials.
Overview
The document provides detailed specifications and type designation keys for various measuring modules and components used in industrial applications, particularly focusing on flow measurement devices.
Specifications
The document lists different housing materials such as stainless steel, PTFE, and brass, along with their respective temperature and pressure ratings.
Type Designation Key
A comprehensive type designation key is provided to identify devices based on their configuration, housing material, measuring chamber, rotary piston material, seal set, and flange drillings.
Modules and Order Numbers
The document details various modules such as ARD, AMD, and PMD, along with their type designations and order numbers.
ATEX Modifications
Modifications for ATEX devices are highlighted, ensuring compliance with safety standards for explosive environments.
Accessories and Accreditations
Information on accessories, accreditations, and compliance with the Pressure Equipment Directive (PED) is included.
Contact Information
The document concludes with contact details for AQUAMETRO AG for further inquiries and access to certificates.
See more

Catalog excerpts

DOMINO For chemical liquids-1

VD 5-111 e 08.2007 Applications Flow measurement of liquids in chemical, chemotechnical, pharmaceutical, cosmetic and other industries. Batching and filling operations. Your Benefits • Highly flexible mounting with least space requirements • Suitable for both conductive and non conductive liquids • Flow disturbances do not influence proper operation and accuracy • Long life with low maintenance DOMINO For chemical liquids Features • Product versions for safe areas or for hazardous areas (ATEX) • Modular products with wide range of flow sensors, displays, pulsers and batching controls • Mechanical, pneumatic and electronic batching controls

 Open the catalog to page 1
DOMINO For chemical liquids-2

2 DOMINO - the modular flow measurement concept System overview Page 4 ARD rotary piston flowmeters for 15...30.000 l/h • Nominal diameter DN 15, 20, 25, 40 and 50 mm • Operating pressures PN 10, 16, 25 or 40 • Fluid temperatures up to 180 °C • Modular meter concept in various materials • Measuring error limits ± 0,5 % of effective value • For high viscosity range up to about 10.000 mPa·s • Swivelling roller register for optimal readability • Special-purpose calibrations for differential pressure measurement (optional) • All flowmeters available with various modules according to need Page 9 AMD...

 Open the catalog to page 2
DOMINO For chemical liquids-3

VZTH 8 rotary piston flowmeter for 5...150 l/h In addition to the DOMINO range, a flowmeter is also available for lower flows. For detailed technical data, please see our separate Technical Documentation. Pulsers Page 20 System planning Page 21 Ordering information Page 23 Accreditations Page 28 3

 Open the catalog to page 3
DOMINO For chemical liquids-4

System overview Meter Ancillaries • display in volumetric units (litre or m3), special version with display in US-Gallons available • with pulser, roller counter or for batching devices Measuring Units • different measuring principles (ARD, AMD and PMD) • various materials according to the meter type (stainless steel, cast iron, brass, PTFE plastics) • flanges according to DIN (in general also available with ANSI orJIS borings) 4 RW Roller register • local totalization RV Roller register with integral reed-type pulser • local totalizing • pulser for remote totalizing • not for use in hazardous...

 Open the catalog to page 4
DOMINO For chemical liquids-5

5 Accessories • batching devices for manual, semi-automatic and automatic control GTAS module Intermediate drive for AS or ASP batching control AM066166 INA module Pulser for electronical batching units AM066167 AM066138 AM066139 AM066147.4 AMD Vane Wheel Meters for chemical liquids Nominal diameter 25, 40 mm Nominal pressure 16, 25 bar Temperature 90, 180 °C Flow rate 140 - 12’000 l/h AM066148.4 PMD Vane Wheel Meters for cold and hot water / batching Nominal diameter 20, 25, 40 mm Nominal pressure 16 bar Temperature 90 °C Flow rate 100 - 20’000 l/h MS-KP Mounting set for compact mounting F131...

 Open the catalog to page 5
DOMINO For chemical liquids-6

6 Applications • ARD rotary piston flowmeters for pure chemical liquids of various types • AMD vane wheel flowmeters for chemical liquids • PMD vane wheel flowmeters for water (in particular for dosing) Selection of commonly measured liquids Acetic acid Acetone Animal fats Ammonium hydroxide, ammonia solutiuon Bromium hydroxide, bromic acid Butyl acetate, acetic butyl ester Chloroform, trichloromethane Citric acid Diethylene glycol Distilled water Ethyl acetate, acetic ether, acetic ester Ethyl alcohol, alcohol, ethanol Ethyl ethylene, ethylene, diethyl ethylene Ethylene glycol Formaldehyde solution...

 Open the catalog to page 6
DOMINO For chemical liquids-7

7 Operation principles ARD range AMD and PMD series • Works on the volumetric principle with rotary pistons • Works on the velocity measuring principle with multi-jet vane wheel • Wide measuring range with high precision • Extremely wide measuring range with good accuracy • Suitable for high viscosities • Largely insensitive to slight impurities in liquid media • Insensitive to flow disturbances • Insensitive to flow disturbances • No power supply needed • No power supply needed Design features ARD range AMD and PMD series • The only moving parts in contact with the liquid medium • The only moving...

 Open the catalog to page 7
DOMINO For chemical liquids-8

8 Permissible measuring error under reference conditions ARD rotary piston flowmeters Reference conditions: Group A Group B Group A comprises the flowmeter with rotary pistons of vulcanized Medium: Water calibration oil (5 mPa·s at 20 °C) rubber, graphite or PTFE. Group B has rotary pistons of aluminium Temperature: 20 °C 18...25 °C or stainless steel. Horizontal meter mounting, reading on register DOMINO ARD rotary piston flowmeters have an infinitely adjustable regulation mechanism for correcting the measuring error curve. So if necessary the measuring tolerance can be set to practically zero...

 Open the catalog to page 8
DOMINO For chemical liquids-9

9 DOMINO ARD rotary piston flowmeters Technical data • For chemical liquids with viscosities up to about 10 000 mPa·s • For horizontal or vertical installation • Measuring error limits ±0.5 % of effective value, repeatability ±0.1 % Max. temperature 40, 50, 90, 130 or 190 °C (according to version) • Max. pressure 10, 16, 25 or 40 bar (according to version) • Threaded connections (brass housing) • Combinable with all DOMINO modules • Special versions with units of measurement in US gallons or with different flangestandards (JIS, ANSI) on request 1) Overall lengh with PTFE housing is 260 mm. 2)...

 Open the catalog to page 9
DOMINO For chemical liquids-10

Measuring sensors and materials * Corrosion and acid-resistant steel (CrNiMo) to DIN 1.4408 / 1.4435 / 1.4404 10 Type Component Material ARD 1000 Housing Brass (threaded connections) or spherolitic cast iron (threaded or flanged connections) Measuring chamber Brass / PPS (130 °C) or brass / PTFE (180 °C) Seals FPM (fluoroelastomer) Rotary pistons Aluminium, hard rubber, graphite or PTFE ARD 2000 Housing Spherolitic cast iron Measuring chamber Stainless steel* / PPS (130 °C) or stainless steel* / PTFE (180 °C) Seals FPM or PTFE (fluoroelastomer or polytetrafluoroethylene) Rotary pistons Hard rubber,...

 Open the catalog to page 10

All INTEGRA Metering AG catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.