Refrigeration units Commercial Range Product catalogue 2014 edition
Open the catalog to page 1innovative refrigeration solutions innovative refrigeration solutions INTARCON is the Spanish leader in manufacturing of self-contained commercial refrigeration units and systems. Our engineering and manufacturing facilities, based on the South of Spain, take profit of the synergies from a long-established technological cluster of equipment manufacturing industries operating in the refrigeration and air conditioning sectors. The human team at INTARCON, with a valuable experience in these sectors, focuses its effort to the development and manufacturing of a new range of self-contained compact...
Open the catalog to page 2Units and systems preselection — Not appropiated + Appropiated ++ Recommended Nominal cooling capacity (kW) EQUIPOS COMPACTOS MONOBLOCK EQUIPOS SEMICOMPACTOS COMERCIALES SPECIAL APPLICATIONS Process roomsn Cheese and cold meat Fruits, vegetables and flowers Packaged products HIGH POSITIVE NEGATIVE temperature temperature temperature T: +15 to 9 ºC T: +10 to -5ºC T: -15 to -25ºC Cold room volume MOTOCONDENSING UNITS Power regulation
Open the catalog to page 3innovative refrigeration solutions Industrial range product Nominal cooling capacity (kW) Cold room volume Construction features Type of construction Type of condenser and control Axial proportional Axial proportional Cubic High humidity Axial proportional Axial proportional Centrifugal split Centrifugal proportional Centrifugal split Centrifugal proportional Centrifugal split Axial proportional Centrifugal split Axial proportional Expansion valve Solenoid valve Electronical controller Expansion valve Solenoid valve Electronical controller Low-profile double-flow Expansion valve Solenoid valve...
Open the catalog to page 4INTARCON units and systems are identified according to their code, giving information about the model description. Units and systems preselection Industrial range product Cold room simple calculation Monoblock units Application Positive temperature Negative temperature High temperature High humidity Wine cellars Configuration Monoblock Split Motocondensing unit Construction Vertical Roof-top Horizontal Low-noise High humidity Wine cellars Axial condensation Centrifugal condensation Cubic evaporating unit Double-flow evaporating unit Quasi-static evaporating unit Wine cellar evaporating unit Electronic...
Open the catalog to page 5innovative refrigeration solutions Cold room simple calculation Cooling needs quick calculation The following chart shows recommended cooling needs for high temperature process rooms and cold storage rooms at positive and negative temperature according to the calculation basis. With floor panel I No floor panel NEGATIVE TEMPERATURE Cooling needs correction factors We suggest the application of some correction factors in order to get the cooling needs for a non-standard cold where Pfc represents the corrected cooling capacity, Pf represents non corrected cooling capacity and correction factors...
Open the catalog to page 6Commercial monoblocks 77 Refrigerant load below 2,5 kg. 77 Tropicalised design for ambient temperature up to 45 ºC. 77 Thermostatic expansion valve. 77 Hot gas defrosting. 77 New refrigerants R-134A and R-407A. intartop Self-contained monoblock refrigeration units for wall-mounting installation in small cold rooms at positive and negative temperature. Available in standard, centrifugal and high performance versions, with drop-in or plug-in mounting through the cold room wall. 77 Simple installation on the roof of the cold room. 77 Centrifugal version for a ducted outlet of hot condensing air....
Open the catalog to page 7innovative refrigeration solutions intartop 77 Tropicalised design for high ambient temperature up to 45ºC. 77 Thermostatic expansion valve. 77 Hot gas defrosting with evaporator temperature control. 77 Monoblock unit with refrigerant load lower than 2,5 kg. Roof-top monoblock units for small-size chiller and freezer cold rooms, for their installation on the roof. Technical features • R-404A or R-134A refrigerant load, below 2,5 kg. • Hermetic reciprocoating compressor. • High and low pressure switches. • Thermostatic expansion valve (except for MCR lower than 1,5 HP featuring capillary expansion)....
Open the catalog to page 8axial and centrifugal roof-top monoblocks series MCR / BCR Positive temperature Axial version Cooling capacity / Cold room volume, according to cold room temp. (1) Nominal Max. absorbed absorb. power Intensity (kW) (A) Sound Weight pressure (kg) level dB(A) (3) Power supply Axial Series / Model Centrifugal version Price (€) axial Centrifugal Series / Model Negative temperature Axial version Cooling capacity / Cold room volume, according to cold room temp. (1) Nominal Max. absorbed absorb. power Intensity (kW) (A) Sound Weight pressure (kg) level dB(A) (3) Power supply Axial Series / Model • R-407A...
Open the catalog to page 9innovative refrigeration solutions intarblock 77 Tropicalised design for high ambient temperature up to 45ºC. 77 Thermostatic expansion valve. 77 Hot gas defrosting with evaporator temperature control. 77 Monoblock unit with refrigerant load lower than 2,5 kg. Self-contained monoblock units for wall-mounting installation in small cold rooms at positive and negative temperature. Technical features • 230V-I-50Hz or 400V-III-50Hz power supply. • Minimal R-404A or R-134A refrigerant load. • Hermetic reciprocating compressor. • High and low pressure switches. • Thermostatic expansion valve (except...
Open the catalog to page 10axial and centrifugal wall monoblocks series MCV / BCV Positive temperature Axial version Cooling capacity / Cold room volume, according to cold room temp. (1) Compressor Power supply Axial Series / Model Nominal Max. absorbed absorb. power Intensity (kW) (A) Sound Weight pressure (kg) level dB(A) (2) Centrifugal version Price (€) axial Centrifugal Series / Model Negative temperature Axial version Cooling capacity / Cold room volume, according to cold room temp. (1) Nominal Max. absorbed absorb. power Intensity (kW) (A) Sound Weight pressure (kg) level dB(A) (2) Power supply Axial Series / Model...