Catalog excerpts
Commercial monoblocks 77 Refrigerant load below 2,5 kg. 77 Tropicalised design for ambient temperature up to 45 ºC. 77 Thermostatic expansion valve. 77 Hot gas defrosting. 77 New refrigerants R-134A and R-407A. intartop Self-contained monoblock refrigeration units for wall-mounting installation in small cold rooms at positive and negative temperature. Available in standard, centrifugal and high performance versions, with drop-in or plug-in mounting through the cold room wall. 77 Simple installation on the roof of the cold room. 77 Centrifugal version for a ducted outlet of hot condensing air. intarblock Self-contained monoblock refrigeration units for roof-top installation in small cold rooms at positive and negative temperature. Available in standard and centrifugal versions, with mounting on the roof of the cold room. 77 Simple installation trough the wall of the cold room. 77 Centrifugal version for a ducted outlet of hot condensing air. 77 Weatherproof version.
Open the catalog to page 1innovative refrigeration solutions intartop 77 Tropicalised design for high ambient temperature up to 45ºC. 77 Thermostatic expansion valve. 77 Hot gas defrosting with evaporator temperature control. 77 Monoblock unit with refrigerant load lower than 2,5 kg. Roof-top monoblock units for small-size chiller and freezer cold rooms, for their installation on the roof. Technical features • R-404A or R-134A refrigerant load, below 2,5 kg. • Hermetic reciprocoating compressor. • High and low pressure switches. • Thermostatic expansion valve (except for MCR lower than 1,5 HP featuring capillary...
Open the catalog to page 2axial and centrifugal roof-top monoblocks series MCR / BCR Positive temperature Axial version Cooling capacity / Cold room volume, according to cold room temp. (1) Nominal absorbed power (kW) Sound Weight pressure (kg) level dB(A) (3) Power supply Axial Series / Model Centrifugal version Centrifugal Series / Model Nominal absorbed power (kW) Negative temperature Axial version Cooling capacity / Cold room volume, according to cold room temp. (1) Sound Weight pressure (kg) level dB(A) (3) Power supply Axial Series / Model • R-407A refrigerant. to consult • Change to 400 V-III-50 Hz power...
Open the catalog to page 3All Intarcon catalogs and technical brochures
-
High humidity
2 Pages
-
Intarsplit axial
4 Pages
-
Intarbox
6 Pages
-
Sigilus
6 Pages
-
intarPACK centrifugal
5 Pages
-
Glycol chillers
15 Pages
-
Commercial range catalogue
36 Pages
-
ACH / MCH / HCH / BCH series
8 Pages
-
MSV / BSV series
5 Pages
-
MSF / BSF series
4 Pages
-
HSF / HSH series
3 Pages
-
ASF / ASH series
5 Pages
-
MSH / BSH series
6 Pages
-
MCR / BCR series
4 Pages
-
MCV / BCV series
5 Pages