1. Catalogs
  2. Instrument Systems
  3. DSP 200 - Photometer for goniophotometric measurements

DSP 200 - Photometer for goniophotometric measurements

DSP 200 - Photometer for goniophotometric measurements

DSP 200 - Photometer for goniophotometric measurements

Product catalog summary
Product Overview
The DSP 200 is a Class L photometer designed for goniophotometric measurements, conforming to standards such as DIN 5032-7 (2017), CIE 69, CIE 121, and EN 13032-1. It features a wide measuring range from 0.1 mlx to 200 klx, suitable for all standard light sources including PWM LEDs. The device ensures consistent measurement display across various components and software, with excellent stability and low noise due to detector cooling. Integration is facilitated via CAN bus and an integrated color display with touchscreen.

Key Features
The DSP 200 excels in precision, linearity, and measurement speed, suitable for various applications and distances. It is particularly adept at measuring modern light sources like pulse-width modulated LEDs and traditional sources such as incandescent and halogen lamps. The photometer uses a cooled silicon photoelement for high stability and precision. Accessories include stray light tubes, stands, ceiling mounts, and optical benches.

Functionality
The photometer's fast internal sampling rate allows precise measurement of light distribution from pulse-width modulated sources. It features eight measuring ranges with automatic switching for excellent resolution and dynamic range. The DSP 200 is connected via CAN-bus to controllers like AMS or LGS, supporting multiple measuring receivers. Calibration is traceable to national luminous intensity standards.

Measurement Capabilities
Optimized for pulse-width modulated light sources, the DSP 200 uses a digital filter to eliminate signal modulations and interferences. The fast digital signal processor ensures stability and repeatability.

Integrated Photometer Head
The photometer head features a silicon photodiode with V(λ) correction, achieving excellent spatial resolution. Detector cooling minimizes dark current influence, and full filtering reduces non-uniform illumination errors.

Software Applications
LightCon software supports photometric measurements for automotive and general lighting applications, offering modular design and compatibility with various goniophotometers and spectroradiometers. SpecWin Pro supports SSL and general lighting measurements, enabling fast data collection and graphical representation.

Technical Specifications
The DSP 200 is a system photometer for laboratory use, with a measurement range from 0.1 mlx to 200 klx. It features a silicon photodiode with V(λ) spectral adaptation and Peltier cooling. The display unit offers direct indication of measurements in lx or cd, with auto-adaptive range selection. The device supports rapid grid measurements and is suitable for continuous duty.

Environmental and Compliance
The DSP 200 operates within a temperature range of +5 °C to +40 °C and complies with CE, FCC, and KC standards. It is recommended to calibrate the device annually or as per user quality management requirements.
See more

Catalog excerpts

DSP 200 - Photometer for goniophotometric measurements-1

DSP 200 DSP 200 photometer for goniophotometric measurements We bring quality to light.

 Open the catalog to page 1
DSP 200 - Photometer for goniophotometric measurements-2

DSP 200 – For ultra-fast measurement of spatial light distribution with the goniophotometer Product highlights at a glance y C lass L photometers conforming to DIN 5032-7 (2017), CIE 69, CIE 121 and EN 13032-1 y ide measuring range of 0.1 mlx (display resolution) W to 200 klx for all standard light sources, including PWM LED y C onsistent display of measurements (device display, connected system components and software) y E xcellent stability and lowest noise level due to detector cooling y S ystem integration via CAN bus, integrated color display with touchscreen 01 \\ DSP 200 – For ultra-fast...

 Open the catalog to page 2
DSP 200 - Photometer for goniophotometric measurements-3

Measurement of pulse-width modulated light sources To dim the LED or LED module, e.g. for realizing various functions such as brake and position light with one and the same light source, luminaries are often operated with pulse width modulation. Typical frequencies range from 80 Hz to 1 kHz. Some extremely short duty cycles are used here. The DSP 200 The exceptionally fast internal sampling rate enables precise measurement of the light distribution of pulse-width modulated light sources with different frequency, even with extremely short duty cycles. This is due to a highspeed digital signal...

 Open the catalog to page 3
DSP 200 - Photometer for goniophotometric measurements-4

► Fast “on-the-fly” measurements / Integrated photometer head The location-dependent luminous intensity of the sample is measured strictly position-synchronous while the goniometer is in motion. The automatic measuring range switchover remains active, in order to map the different intensities of the sample with the best-possible dynamic range. The DSP 200 photometer is most commonly used for fast “on-the-fly” grid and slice measurements with the goniophotometers of the Optronik line AMS 200, 3000 and 5000, as well as our goniophotometers LGS 350, 650 and 1000. The fast data transmission rate...

 Open the catalog to page 4
DSP 200 - Photometer for goniophotometric measurements-5

Various methods of spectral measurement. Current standards such as EN 13032-1 (2004) and DIN 5032-7 (2017) allow for a characteristic that is crucial to the accuracy of photometric measurements of standard photometer heads, the so-called f9, the influence of non-uniform illumination of a photometer head. For test objects with sharp gradients, e.g. automobile headlights and, in particular, modern ADB and pixel headlights, decisive advantages are offered by photometers with full filtering, by which the spectral sensitivity is virtually constant over the entire light entry surface. Although other...

 Open the catalog to page 5
DSP 200 - Photometer for goniophotometric measurements-6

► Software for different applications Lamps and test objects can be stored and managed in a structure definable by the user himself. The software contains a complete regulation database acc. to UN-ECE, SAE and FMVSS108, ICAO and FAA standards that are regularly updated by Instrument Systems. Regulations are also freely editable, and there is an option of defining manufacturer’s limits, in addition to standard limits. Light distributions can be graphically represented as isocandela diagrams in the form of spherical scan grids, wall projections, driver’s and bird’s-eye views. They can be superimposed...

 Open the catalog to page 6
DSP 200 - Photometer for goniophotometric measurements-7

► Technical data according to DIN 5032-8 (2017)

 Open the catalog to page 7
DSP 200 - Photometer for goniophotometric measurements-8

11 DSP 200 is a fast photometer designed for fast goniophotometric measurement so that this value is irrelevant for its evaluation. 2) Calculation of total parameter fges = Ucal + f + u + r + f3 + f4 + f5 + f6 + f7 + f-n Instrument Systems is continually working on the further development of its products. Technical changes, errors and misprints do not justify claims for damages. For all other purposes, our Terms and Conditions of Business shall be applicable. Instrument Systems KONICA MINOLTA Group

 Open the catalog to page 8