1. Catalogs
  2. Instrument Systems
  3. DMS Goniometer systems for display characterization

DMS Goniometer systems for display characterization

DMS Goniometer systems for display characterization
1 / 24 PagesView full catalog

DMS Goniometer systems for display characterization

Product catalog summary
Introduction to DMS Series
The DMS series is a globally recognized standard for analyzing electro-optical displays and components. It includes four goniophotometric systems for measuring luminance, contrast, chromaticity, flicker, and response time. Originating in the 1980s, it has evolved to meet industry demands, contributing to standardized measurement methods.
Customer Applications and Challenges
The DMS series serves a diverse customer base, including material and component manufacturers, display panel makers, and brand owners. It supports product specification, optimization, and quality control in sectors like consumer electronics, automotive, and medical industries.
Functional Principle of DMS Systems
DMS systems use a high-precision goniometer for full viewing direction scans and uniformity checks. They feature integrated driving units and microscope optics for precise measurement spot selection. Optional enhancements include a LumiTop imaging colorimeter for 2D angular measurements.
DMS Goniometers Overview
The series includes five models (DMS 904, 903, 803, 505, and 201) with varying levels of automation and measurement capabilities, equipped with motorized or manual axes and accessories for comprehensive display characterization.
Combined Light Measurement Devices
DMS systems integrate spectrometers and photometers for simultaneous photometric and spectral measurements. The CAS 140D spectroradiometer is noted for its high accuracy and sensitivity, essential for precise display characterization.
Technical Specifications
The document details specifications for the spectroradiometer and photometer, emphasizing accuracy, dynamic range, and suitability for laboratory and production environments. The CAS 140D is highlighted for color accuracy and low luminance measurement, while the PMT 3 photometer is optimized for fast luminance changes.
DMS Series Overview
The DMS series is versatile, suitable for various applications with specific requirements, particularly accurate angular measurements. It can be customized for applications like automotive displays and AR/VR measurements. The DMS 904 model offers flexibility for large curved displays.
Heat-Cool System (HCS)
The HCS can be integrated with DMS systems for temperature-dependent measurements, maintaining components at room temperature. It allows precise temperature control from -40 °C to +105 °C and includes accessories like extension rings and rotary stages.
SCAN 300 Scanning Stage
The SCAN 300 is an optional motorized x-y scanning stage extending the measurement range for displays up to 16 inches, integrated with DMSControl software for automated measurements.
DUT Driving Unit
DMS systems include a driving unit for connecting and driving various devices under test (DUTs), compatible with multiple connection types and offering an advanced display control interface for integrating customer-specific equipment.
Light Sources and Illumination Devices
The document discusses the impact of ambient light on display performance and the importance of simulating different lighting conditions. Various illumination devices, including halogen and xenon lamps, are available for comprehensive display characterization.
Software Package
The DMS series comes with DMSControl and ViPer Evaluation software for device control, measurement automation, and data analysis. The software supports automated measurement sequences and offers extensive evaluation functions, including angular scans, flicker graphs, and chromaticity graphs. The ViPer Report Generator allows easy export of measurement data into customized reports.
Specifications
  • Main System Mechanics: The DMS systems offer various scan ranges for theta inclination and phi rotation, with positioning accuracy and resolution specified for each model. The systems support different dimensions and weights, with specific power and space requirements.
  • Facility Requirements: All systems require a power supply of 200-250 VAC, 50/60 Hz, and have specific operating temperature and humidity conditions.
Order Information
  • Each DMS model (201, 505, 803, 903, 904) is described with its components, such as goniometers, microscope viewing optics, and software.
  • Options include spectrometers, photometers, control electronics, temperature chambers, light sources, and software for enhanced functionality.
Software Options
  • Software packages like DMSControl and ViPer are available for control, measurement, and data export. Additional modules support device control, report generation, and specific measurement tasks.
Conclusion
Instrument Systems offers a comprehensive range of DMS systems with customizable options to meet various measurement and evaluation needs. The document emphasizes the importance of adhering to facility requirements and provides contact information for further inquiries.
See more

Catalog excerpts

DMS Goniometer systems for display characterization-1

Instrument Systems KONICA MINOLTA Group DMS Series Goniometer systems for display characterization

 Open the catalog to page 1
DMS Goniometer systems for display characterization-2

Fig. 1: he diffusing hemisphere is a valuable DMS-accessory for contrast measurement of reflective displays T The DMS series is recognized as a worldwide standard and reference for extensive analyses of electrooptical displays, related materials and components at every stage of the engineering and production process. It consists of four individual goniophotometric systems, varying in size and function. All DMS systems enable: y easurement of luminance, M contrast and chromaticity under different display driving states and viewing directions y etermination of flicker and D response time y ualification...

 Open the catalog to page 2
DMS Goniometer systems for display characterization-3

02 \\ Diverse customers, various measurement challenges Analysis Quality Control CHALLENGES Material & Component Maker LC/OLED cells Optical films Display Panel Maker Display Integrator LC/OLED panels Display Manufacturer Display systems Brand owner Fig. 2: Applications in the display industry The versatility of the DMS series is mirrored in the diversity of our customers. Instrument Systems has always the perfect system – for all kinds of DUTs and measurement challenges such as product specification, optimization or quality control. Material, component and display panel manufacturers analyze...

 Open the catalog to page 3
DMS Goniometer systems for display characterization-4

The instruments of the DMS series are designed to measure and qualify any electro-optical display under typical application situations representing complex human handling: Y Control of the viewing direction ($ axis, 0 axis) Y Control of the lateral measurement position (X, Y axis) Y Control of ambient illumination (illuminance level, geometry, spectral distribution, angle of incidence) Y Control of DUT temperature Y Control of displayed patterns or electrical driving parameters In order to obtain accurate and repeatable measurement results, one parameter is varied while all others are kept constant....

 Open the catalog to page 4
DMS Goniometer systems for display characterization-5

A heat-cool system may be integrated for temperature-dependent measurements and conformance testing as required e.g. for automotive standards. Different illumination devices simulate the disturbing impact of ambient light on displays. A transmissive light source can be used to qualify passive LC components or polarizer films. A comprehensive software package (DMSControl/ViPer Evaluation) controls automated measurement procedures and generates comprehensive result reports. Each DMS basic system can easily embed customized solutions such as fixtures, additional optics or specific driving devices....

 Open the catalog to page 5
DMS Goniometer systems for display characterization-6

1 Limited thickness of DUT. Max. DUT thickness: 15 mm.

 Open the catalog to page 6
DMS Goniometer systems for display characterization-7

A key feature of the optical design of the DMS systems is that photometric parameters and spectral distributions can be determined within one measuring process. This concept allows measurement of multiple parameters within one system. Microscope optic A spectrometer and photometer are connected via optical fiber to a microscope optic, which represents the human observer. The microscope features either a view finding camera or an eyepiece with magnification optics and integrated target crosshairs for accurate set-up and focusing on the DUT surface. It enables reproducible selection, either motorized...

 Open the catalog to page 7
DMS Goniometer systems for display characterization-8

◄ Fig: 5: CAS 140D - Reference spectroradiometer with highest color accuracy High-end spectroradiometer CAS 140D The determination of all photometric and colorimetric quantities results from software calculation of the spectral measurement data. This is why the quality and precision of the spectroradiometer in action is extremely important. The CAS 140D, which is recommended for the DMS systems, combines highest measurement accuracy, reliability, and stability. Its excellent technical specifications and high optical throughput make it an extremely versatile device for usage in reference laboratories...

 Open the catalog to page 8
DMS Goniometer systems for display characterization-9

Fast photometer PMT 3 High-quality displays need fast transitional periods to visualize moving images. Thus, rapid temporal changes in luminance have to be measured, necessitating an extremely fast-performing measurement device. The PMT 3, a fast photometer with photomultiplier tube, has been optimized for this application. Due to its high sensitivity, the PMT 3 is also suited to light detection of very week signals. Transfer and extremely fast switching characteristics e.g. of OLED cells or light artefacts as flicker can be measured in the microsecond range. Internal low pass filters allow disturbing...

 Open the catalog to page 9
DMS Goniometer systems for display characterization-10

06 \\ MS series customized for D different applications The DMS series is used in a wide range of applications. Each application has its own requirements, and needs different modification. If the application calls for highly accurate, repeatable angular measurements, the DMS series is the best choice. The modular concept of the DMS series makes this special customization possible, saving time and effort. The DMS 904 with extra big chamber and heat-cool system gives even more flexibility concerning DUT dimensions, e.g. for large curved automotive displays. Examples of customized solutions 2D angular...

 Open the catalog to page 10
DMS Goniometer systems for display characterization-11

Wafer testing y ngular distribution of luminous A intensity y ominant wavelength shift D y A adaption for high angular N resolution y otorized probes for DUT driving M y emperature controlled T Large scale Automotive display testing (DMS 904) y dditional motorized x-axis for A curved displays y xtra big chamber and heat-coolE system for large devices Our system experts will be pleased to provide competent advice on your particular application. Together we will find the right solution for your application. Instrument Systems } DMS Series

 Open the catalog to page 11
DMS Goniometer systems for display characterization-12

07 \\ CS Heat-cool system H Each DMS system can be extended with an appropriate heat-cool system to take temperature-dependent measurements of optical display properties and conformance testing. Since only the DUT is exposed to the airflow, the microscope, LMDs and goniometer remain constant at room temperature. Precise airflow control allows measurement of the test specimen at stabilized temperatures in the range -40 °C to +105 °C. HCS systems can be complemented with the following accessories: y Extension rings for testing different DUT heights y R otary stage for smaller LC test cells to measure...

 Open the catalog to page 12

All Instrument Systems catalogs and technical brochures

  1. VTC 2400

    2  Pages

  2. CAS 125-HR

    2  Pages

  3. Photometers

    24  Pages

  4. LEDGON 100

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.