CAS 120-HR High Resolution Array Spectroradiometer Key features at a glance y High resolution down to 0.2 nm FWHM, 0.05 nm data point interval y igh-performance and cost-effective for H production and laboratory y own to 4 ms integration time D y ntegrated density filter wheel I The high resolution CAS 120-HR is based on Instrument Systems’ high-performance spectroradiometer CAS 120. Particularly designed for the measurement of narrow band emitters, e.g. laser diodes, the CAS 120-HR combines high spectral resolution and short testing times for sophisticated and price-sensitive production and laboratory applications. \\ VERY HIGH SPECTRAL RESOLUTION The CAS 120-HR models achieve very high spectral resolutions down to 0.2 nm (0.05 nm data point interval) for a spectral measuring range of 80 nm (see figure below). Measuring ranges of 120 and 160 nm result in spectral resolutions of 0.3 and 0.4 nm, respectively. A back-thinned and back-illuminated CCD array sensor with 2048 x 16 pixels is used for detection in the CAS 120-HR. This sensor design in combination with hardware binning of the vertical pixels offers a high level of sensitivity and large dynamic range (10800 : 1). The CCD allows capturing the spectrum of an optical emitter in a single exposure. Additionally, short integration times down to 4 ms make the CAS 120-HR particularly suitable for the measurement of emitters with pulsed and continuous operating modes. \\ TECHNICAL SPECIFICATIONS CAS 120-HR High Resolution Array Spectroradiometer Spectral range ~ Spectral radiant power of selected Ar and Xe emission lines. They were measured with a CAS 120-HR model with a spectral range of 902 to 982 nm and corresponding spectral resolution of 0.2 nm (FWHM). \\ CUSTOMIZED WAVELENGTH RANGES The CAS 120-HR offers a selection of different gratings with 1200, 1500 and 1800 lines/mm. Typical measuring ranges of 80, 120 and 160 nm are available in the spectral range from 800 to 1000 nm. Further spectral ranges in the VIS are available upon request. Measuring ranges (typical) Spectral resolution (typical) Data point interval (typical) Wavelength accuracy Integration time Sensor dynamic range Non-Linearity

Open the catalog to page 1
CAS 120-HR  High Resolution Array Spectroradiometer - 2

\\ TECHNICAL SPECIFICATIONS CAS 120-HR High Resolution Array Spectroradiometer Spectrograph Focal length, f number, grating type Approx. 120 mm, f/3.5, plane reflection grating Filter wheel Electrical data AD converter 1 TTL input with ascending slope; 2 software-controlled TTL outputs; 1 TTL output with flash pulse Baseline noise Power supply Power consumption Ambient temperature 15 – 35 °C; relative humidity 70% max., non-condensing Valid standards In conformity with EN 61010-1:2002-08 (safety requirements governing electrical equipment for measurement, control and laboratory use) \\...

Open the catalog to page 2

All Instrument Systems catalogs and technical brochures

  1. VTC 2400

    2 Pages

  2. CAS 125-HR

    2 Pages

  3. Photometers

    24 Pages

  4. LEDGON 100

    4 Pages